These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 3879054)

  • 1. [Detection, quantification and localization of myocardial infarcts: comparison of thallium single photon emission computer tomography with biplane angiography].
    Hoffmeister HM; Kaiser W; Hanke H; Müller-Schauenburg W; Karsch KR; Feine U; Seipel L
    Z Kardiol; 1985 Nov; 74(11):625-32. PubMed ID: 3879054
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Detection of ischemia with thallium-201 single photon emission computerized tomography (SPECT) and radionuclide ventriculography in comparison with stress cineventriculography].
    Hoffmeister HM; Hanke H; Unterberg R; Voelker W; Müller-Schauenburg W; Karsch KR
    Z Kardiol; 1988 Feb; 77(2):115-9. PubMed ID: 3259052
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantification of myocardial ischemia and infarction with single photon emission computed tomography.
    Hoffmeister HM; Hanke H; Unterberg R; Voelker W; Kaiser W; Müller-Schauenburg W; Karsch KR
    Eur J Nucl Med; 1989; 15(1):26-31. PubMed ID: 2783908
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Detectability of stress-induced ischemic lesion in previous myocardial infarction using 201T1 myocardial single photon emission computed tomography].
    Futagami Y; Hamada M; Ichikawa T; Yamakado T; Konishi T; Nakano T; Takezawa H; Takeda K; Maeda H
    J Cardiogr; 1983 Dec; 13(4):821-32. PubMed ID: 6332158
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Contrast-enhanced MRI and routine single photon emission computed tomography (SPECT) perfusion imaging for detection of subendocardial myocardial infarcts: an imaging study.
    Wagner A; Mahrholdt H; Holly TA; Elliott MD; Regenfus M; Parker M; Klocke FJ; Bonow RO; Kim RJ; Judd RM
    Lancet; 2003 Feb; 361(9355):374-9. PubMed ID: 12573373
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Correlation of thallium uptake with left ventricular wall thickness by cine magnetic resonance imaging in patients with acute and healed myocardial infarcts.
    Lawson MA; Johnson LL; Coghlan L; Alami M; Tauxe EL; Reinert SE; Singleton R; Pohost GM
    Am J Cardiol; 1997 Aug; 80(4):434-41. PubMed ID: 9285654
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Usefulness and limitations of thallium-201 myocardial scintigraphy in delineating location and size of prior myocardial infarction.
    Niess GS; Logic JR; Russell RO; Rackley CE; Rogers WJ
    Circulation; 1979 May; 59(5):1010-9. PubMed ID: 428082
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Quantitative correlation between thallium-201 myocardial emission computed tomography and left ventriculography in old myocardial infarction].
    Matsushima H; Mochizuki K; Kawai N; Okada M; Yamamoto S; Yamauchi K; Yokota M; Hayashi H; Sotobata I; Tsuzuki J
    J Cardiogr; 1984 Aug; 14(2):237-46. PubMed ID: 6335890
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Evaluation of myocardial infarction by thallium emission computed tomography].
    Tamaki N; Mukai T; Yamamoto K; Ishii Y; Tamaki S; Kadota K; Kambara H; Kawai C; Torizuka K
    J Cardiogr; 1983 Mar; 13(1):45-55. PubMed ID: 6606004
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [201Thallium single photon emission computer tomography (SPECT) in the functional evaluation of coronary stenosis changes. Results of a comparison of stress scintigraphic and coronary angiographic findings].
    Büll U; Doliwa R; Kirsch CM; Roedler HD; Strauer BE
    Z Kardiol; 1984 May; 73(5):313-20. PubMed ID: 6333114
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [The value of thallium myocardial scintigraphy (single photon emission computerized tomography, SPECT) for diagnosis of ischemia after myocardial infarct].
    Fries P; Thimme W; Haubold R
    Med Klin (Munich); 1994 Nov; 89(11):582-6. PubMed ID: 7815985
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Quantitative assessment of myocardial viability following coronary artery bypass grafting using exercise thallium-201 myocardial single photon emission computed tomography and left ventricular regional wall motion].
    Yamamoto N; Kazui T; Okawa Y; Komatsu K; Araki E; Tanaka A; Tanaka T; Komatsu S; Kubota M
    Nihon Kyobu Geka Gakkai Zasshi; 1989 Dec; 37(12):2468-76. PubMed ID: 2625558
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quantification of infarct size by thallium-201 single-photon emission computed tomography using the unfolded map method. Comparison with QRS score and angiographic infarct size at 4 weeks after infarction.
    Shimada T; Tsuda N; Kamihata H; Suga Y; Kurimoto T; Iwasaka T; Inada M
    Clin Cardiol; 1994 Apr; 17(4):184-90. PubMed ID: 8187368
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Thallium single photon emission computed tomography following thrombolysis: missing relation to left ventricular function].
    Schofer J; Lampe M; Spielmann R; Schlüter M; Mathey DG
    Z Kardiol; 1988 Aug; 77(8):497-502. PubMed ID: 3262962
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of acute Q-wave myocardial infarct size with single photon emission computed tomography imaging of indium-111 antimyosin.
    Antunes ML; Seldin DW; Wall RM; Johnson LL
    Am J Cardiol; 1989 Apr; 63(12):777-83. PubMed ID: 2784620
    [TBL] [Abstract][Full Text] [Related]  

  • 16. SPECT thallium-201 scintigraphy for the detection of left-ventricular aneurysm.
    Morton KA; Alazraki NP; Taylor AT; Datz FL
    J Nucl Med; 1987 Feb; 28(2):168-72. PubMed ID: 3492595
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection of transmural myocardial infarction by single-photon emission computed tomography with thallium-201: comparison with planar imaging.
    Ho FM; Han ML; Lo HM; Huang PJ
    Taiwan Yi Xue Hui Za Zhi; 1989; 88(11-12):1104-8. PubMed ID: 2636247
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Myocardial positron computed tomography using N-13 ammonia for evaluating coronary artery disease: comparison with thallium-201 emission computed tomography].
    Tamaki N; Yonekura Y; Kodama S; Senda M; Saji H; Torizuka K; Kambara H; Kawai C; Konishi Y; Ban T
    J Cardiogr; 1985 Sep; 15(3):553-65. PubMed ID: 3879760
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Clinical significance of the technetium-99m/thallium-201 overlap in acute myocardial infarction].
    Umezawa S; Obayashi T; Chun YH; Adachi H; Kanayama M; Korenaga M; Inada M; Taniguchi K
    J Cardiol; 1989 Dec; 19(4):981-90. PubMed ID: 2562093
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Magnetic resonance tomography image of transmural myocardial infarct in comparison with 99mTc-methoxyisobutylisonitrile SPECT].
    Baer FM; Smolarz K; Jungehülsing M; Theissen P; Sechtem U; Schicha H; Hilger HH
    Z Kardiol; 1992 Aug; 81(8):423-31. PubMed ID: 1413950
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.