These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 38800589)

  • 1. On the importance of precision in cortical bone drilling: Integrating experimental validation and computational modeling.
    Einafshar MM; Rajaeirad M; Babazadeh Ghazijahani A; Skipper Andersen M
    J Orthop; 2024 Oct; 56():70-76. PubMed ID: 38800589
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical Evaluation of Temperature Rising and Applied Force in Controlled Cortical Bone Drilling: an Animal in Vitro Study.
    Ein-Afshar MJ; Shahrezaee M; Shahrezaee MH; Sharifzadeh SR
    Arch Bone Jt Surg; 2020 Sep; 8(5):605-612. PubMed ID: 33088862
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An analytical and numerical approach to the determination of thermal necrosis in cortical bone drilling.
    Aydın K; Ökten K; Uğur L
    Int J Numer Method Biomed Eng; 2022 Oct; 38(10):e3640. PubMed ID: 35899364
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Drilling of bone: Effect of drill bit geometries on thermal osteonecrosis risk regions.
    Ali Akhbar MF; Yusoff AR
    Proc Inst Mech Eng H; 2019 Feb; 233(2):207-218. PubMed ID: 30572787
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of thermal necrosis risk regions for different bone qualities as a function of drilling parameters.
    Chen YC; Tu YK; Tsai YJ; Tsai YS; Yen CY; Yang SC; Hsiao CK
    Comput Methods Programs Biomed; 2018 Aug; 162():253-261. PubMed ID: 29903492
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Thermomechanical damage in cortical bone caused by margins of surgical drill bit: A finite element analysis.
    Akhbar MFA
    Comput Methods Programs Biomed; 2023 Apr; 231():107361. PubMed ID: 36736133
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the parameters affecting bone temperature during drilling using a three-dimensional dynamic elastoplastic finite element model.
    Chen YC; Tu YK; Zhuang JY; Tsai YJ; Yen CY; Hsiao CK
    Med Biol Eng Comput; 2017 Nov; 55(11):1949-1957. PubMed ID: 28353132
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effects of multiple drilling of a bone with the same drill bit: thermal and force analysis.
    Tsiagadigui JG; Ndiwe B; Ngo Yamben MA; Fotio N; Belinga FE; Njeugna E
    Heliyon; 2022 Feb; 8(2):e08927. PubMed ID: 35243056
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of experimental thermal, numerical, and mandibular drilling factors in implantology.
    Pirjamalineisiani A; Jamshidi N; Sarafbidabad M; Soltani N
    Br J Oral Maxillofac Surg; 2016 May; 54(4):400-4. PubMed ID: 26493617
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental Study of Thrust Force and Torque for Drilling Cortical Bone.
    Sui J; Sugita N
    Ann Biomed Eng; 2019 Mar; 47(3):802-812. PubMed ID: 30627838
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modeling and experimentation of bone drilling forces.
    Lee J; Gozen BA; Ozdoganlar OB
    J Biomech; 2012 Apr; 45(6):1076-83. PubMed ID: 22281407
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of process parameters on the temperature changes during robotic bone drilling.
    Han Y; Cai C; Lv Q; Song Y; Zhang Q
    Proc Inst Mech Eng H; 2022 Aug; 236(8):1129-1138. PubMed ID: 35821641
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Feed rate control in robotic bone drilling process.
    Boiadjiev T; Boiadjiev G; Delchev K; Chavdarov I; Kastelov R
    Proc Inst Mech Eng H; 2021 Mar; 235(3):273-280. PubMed ID: 33231113
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multi-Objective Optimization in Single-Shot Drilling of CFRP/Al Stacks Using Customized Twist Drill.
    Hassan MH; Abdullah J; Franz G
    Materials (Basel); 2022 Mar; 15(5):. PubMed ID: 35269212
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new thermal model for bone drilling with applications to orthopaedic surgery.
    Lee J; Rabin Y; Ozdoganlar OB
    Med Eng Phys; 2011 Dec; 33(10):1234-44. PubMed ID: 21803638
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Drilling in cortical bone: a finite element model and experimental investigations.
    Lughmani WA; Bouazza-Marouf K; Ashcroft I
    J Mech Behav Biomed Mater; 2015 Feb; 42():32-42. PubMed ID: 25460924
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Thermo-Mechanical and Delamination Properties in Drilling GFRP Composites by Various Drill Angles.
    Khashaba UA; Abd-Elwahed MS; Eltaher MA; Najjar I; Melaibari A; Ahmed KI
    Polymers (Basel); 2021 Jun; 13(11):. PubMed ID: 34204048
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Temperature change during orthopedic drilling procedures: An experimental surgical internal fixation simulation study.
    Pazarcı Ö; Gündoğdu F
    J Orthop; 2023 Dec; 46():58-63. PubMed ID: 37942216
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Novel crescent drill design and mechanistic force modeling for thrust force reduction in bone drilling.
    Liu S; Wu D; Zhao J; Yang T; Sun J; Gong K
    Med Eng Phys; 2022 May; 103():103795. PubMed ID: 35500995
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reducing temperature elevation of robotic bone drilling.
    Feldmann A; Wandel J; Zysset P
    Med Eng Phys; 2016 Dec; 38(12):1495-1504. PubMed ID: 27789226
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.