105 related articles for article (PubMed ID: 38802160)
1.
Dasgupta A; Woodard K; Ramoo B; Frazee C; Garg U
Ann Clin Lab Sci; 2024 Mar; 54(2):258-261. PubMed ID: 38802160
[TBL] [Abstract][Full Text] [Related]
2. Estimating testosterone concentrations in adolescent girls: Comparison of two direct immunoassays to liquid chromatography-tandem mass spectrometry.
McCartney CR; Burt Solorzano CM; Patrie JT; Marshall JC; Haisenleder DJ
Steroids; 2018 Dec; 140():62-69. PubMed ID: 30217784
[TBL] [Abstract][Full Text] [Related]
3. Using mass spectrometry to overcome the longstanding inaccuracy of a commercially-available clinical testosterone immunoassay.
Shi J; Bird R; Schmeling MW; Hoofnagle AN
J Chromatogr B Analyt Technol Biomed Life Sci; 2021 Oct; 1183():122969. PubMed ID: 34628183
[TBL] [Abstract][Full Text] [Related]
4. Low serum testosterone assayed by liquid chromatography-tandem mass spectrometry. Comparison with five immunoassay techniques.
Moal V; Mathieu E; Reynier P; Malthièry Y; Gallois Y
Clin Chim Acta; 2007; 386(1-2):12-9. PubMed ID: 17706625
[TBL] [Abstract][Full Text] [Related]
5. Measurement of total serum testosterone in adult men: comparison of current laboratory methods versus liquid chromatography-tandem mass spectrometry.
Wang C; Catlin DH; Demers LM; Starcevic B; Swerdloff RS
J Clin Endocrinol Metab; 2004 Feb; 89(2):534-43. PubMed ID: 14764758
[TBL] [Abstract][Full Text] [Related]
6. Women in sports: The applicability of reference intervals for 6 commercially available testosterone immunoassays (HemSter Study).
Radišić Biljak V; Đuras A; Čičak H; Vidranski V; Vidranski T; Peersman N; Vermeersch P; Ostroški I; Ružić L; Simundic AM
Clin Biochem; 2020 Oct; 84():55-62. PubMed ID: 32533955
[TBL] [Abstract][Full Text] [Related]
7. Reassessment of the Access Testosterone chemiluminescence assay and comparison with LC-MS method.
Dittadi R; Matteucci M; Meneghetti E; Ndreu R
J Clin Lab Anal; 2018 Mar; 32(3):. PubMed ID: 28643405
[TBL] [Abstract][Full Text] [Related]
8. Measurement of urinary free cortisol by LC-MS-MS: adoption of a literature reference range and comparison with our current immunometric method.
Bianchi L; Campi B; Sessa MR; De Marco G; Ferrarini E; Zucchi R; Marcocci C; Vitti P; Manetti L; Saba A; Agretti P
J Endocrinol Invest; 2019 Nov; 42(11):1299-1305. PubMed ID: 31012054
[TBL] [Abstract][Full Text] [Related]
9. Comparison of Six Automated Immunoassays With Isotope-Diluted Liquid Chromatography-Tandem Mass Spectrometry for Total Thyroxine Measurement.
Yu S; Zhou W; Cheng X; Meng Q; Li H; Hou L; Lu J; Xie S; Cheng Q; Zhang C; Qiu L
Ann Lab Med; 2019 Jul; 39(4):381-387. PubMed ID: 30809984
[TBL] [Abstract][Full Text] [Related]
10. Measurement of Serum Testosterone in Nondiabetic Young Obese Men: Comparison of Direct Immunoassay to Liquid Chromatography-Tandem Mass Spectrometry.
Martínez-Escribano A; Maroto-García J; Ruiz-Galdón M; Barrios-Rodríguez R; Álvarez-Millán JJ; Cabezas-Sánchez P; Plaza-Andrades I; Molina-Vega M; Tinahones FJ; Queipo-Ortuño MI; Fernández-García JC
Biomolecules; 2020 Dec; 10(12):. PubMed ID: 33352636
[TBL] [Abstract][Full Text] [Related]
11. Selected performance characteristics of the Roche Elecsys testosterone II assay on the Modular analytics E 170 analyzer.
Owen WE; Rawlins ML; Roberts WL
Clin Chim Acta; 2010 Aug; 411(15-16):1073-9. PubMed ID: 20385114
[TBL] [Abstract][Full Text] [Related]
12. Validation of a total testosterone assay using high-turbulence liquid chromatography tandem mass spectrometry: total and free testosterone reference ranges.
Salameh WA; Redor-Goldman MM; Clarke NJ; Reitz RE; Caulfield MP
Steroids; 2010 Feb; 75(2):169-75. PubMed ID: 19925815
[TBL] [Abstract][Full Text] [Related]
13. Establishing normal values of total testosterone in adult healthy men by the use of four immunometric methods and liquid chromatography-mass spectrometry.
Montagna G; Balestra S; D'Aurizio F; Romanelli F; Benagli C; Tozzoli R; Risch L; Giovanella L; Imperiali M
Clin Chem Lab Med; 2018 Oct; 56(11):1936-1944. PubMed ID: 29746252
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of new Beckman Coulter 25(OH) Vitamin D assay and potential improvement of clinical interpretation.
Madenci ÖÇ; Orçun A; Yildiz Z; Sirmali R; Tunçbilek N; Yücel N; Temel Y; Bölük A
Biochem Med (Zagreb); 2017 Jun; 27(2):332-341. PubMed ID: 28694724
[TBL] [Abstract][Full Text] [Related]
15. Direct measurement of serum free testosterone by ultrafiltration followed by liquid chromatography tandem mass spectrometry.
Chen Y; Yazdanpanah M; Wang XY; Hoffman BR; Diamandis EP; Wong PY
Clin Biochem; 2010 Mar; 43(4-5):490-6. PubMed ID: 20026023
[TBL] [Abstract][Full Text] [Related]
16. State-of-the-art of serum testosterone measurement by isotope dilution-liquid chromatography-tandem mass spectrometry.
Thienpont LM; Van Uytfanghe K; Blincko S; Ramsay CS; Xie H; Doss RC; Keevil BG; Owen LJ; Rockwood AL; Kushnir MM; Chun KY; Chandler DW; Field HP; Sluss PM
Clin Chem; 2008 Aug; 54(8):1290-7. PubMed ID: 18556330
[TBL] [Abstract][Full Text] [Related]
17. How low can you go? Analytical performance of five automated testosterone immunoassays.
La'ulu SL; Kalp KJ; Straseski JA
Clin Biochem; 2018 Aug; 58():64-71. PubMed ID: 29763574
[TBL] [Abstract][Full Text] [Related]
18. Measurement of unconjugated estriol in serum by liquid chromatography-tandem mass spectrometry and assessment of the accuracy of chemiluminescent immunoassays.
Huang X; Spink DC; Schneider E; Ling H; Rai AJ; Rosano TG; Chen B; Cao ZT
Clin Chem; 2014 Jan; 60(1):260-8. PubMed ID: 24255078
[TBL] [Abstract][Full Text] [Related]
19. Comparison of Direct and Extraction Immunoassay Methods With Liquid Chromatography-Tandem Mass Spectrometry Measurement of Urinary Free Cortisol for the Diagnosis of Cushing's Syndrome.
Mu D; Fang J; Yu S; Ma Y; Cheng J; Hu Y; Song A; Zhao F; Zhang Q; Qi Z; Zhang K; Xia L; Qiu L; Zhu H; Cheng X
Ann Lab Med; 2024 Jan; 44(1):29-37. PubMed ID: 37665283
[TBL] [Abstract][Full Text] [Related]
20. Effect of Carbamazepine 10, 11-Epoxide on Serum Carbamazepine Measurement Using a New CMIA Assay: Comparison of Values Obtained by Using PETINIA, CEDIA and Liquid Chromatography Combined with Tandem Mass Spectrometry.
Dasgupta A; Davis B; Slawson MH; Johnson-Davis KL
Ann Clin Lab Sci; 2016 May; 46(3):242-6. PubMed ID: 27312546
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]