These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 38803133)

  • 1. Design, evolution, and experience with the candy plug device for endovascular false lumen occlusion of chronic aortic dissections.
    Grandi A; D'Oria M; Panuccio G; Rohlffs F; Eleshra A; Torrealba J; Nana P; Lepidi S; Melloni A; Bertoglio L; Kölbel T
    Expert Rev Med Devices; 2024 May; ():1-4. PubMed ID: 38803133
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Open and endovascular reinterventions after Candy Plug false lumen embolization of type B aortic dissection.
    Loschi D; Santoro A; Rinaldi E; Anselmi C; Grignani C; Chiesa R; Melissano G
    J Vasc Surg; 2023 Dec; 78(6):1409-1417. PubMed ID: 37572890
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Self-occluding Candy-Plug: Implantation Technique to Obtain False Lumen Thrombosis in Chronic Aortic Dissections.
    Bertoglio L; Bilman V; Rohlffs F; Panuccio G; Chiesa R; Kölbel T
    J Endovasc Ther; 2023 Dec; 30(6):811-816. PubMed ID: 35707893
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Initial experience with a modified "candy-plug" technique for false lumen embolization in chronic type B aortic dissection.
    Miles D; Arbabi C; McMackin K; Tjaden B; Schonefeld S; Baril D; Gupta N; Gewertz B; Azizzadeh A
    J Vasc Surg Cases Innov Tech; 2023 Jun; 9(2):101075. PubMed ID: 37152918
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Custom Made Candy Plug for Distal False Lumen Occlusion in Aortic Dissection: International Experience.
    Eleshra A; Haulon S; Bertoglio L; Lindsay T; Rohlffs F; Dias N; Tsilimparis N; Panuccio G; Kölbel T;
    Eur J Vasc Endovasc Surg; 2023 Jul; 66(1):50-56. PubMed ID: 36958480
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fate and Consequences of the False Lumen After Thoracic Endovascular Aortic Repair in Type B Aortic Dissection.
    Jubouri M; Patel R; Tan SZ; Al-Tawil M; Bashir M; Bailey DM; Williams IM
    Ann Vasc Surg; 2023 Aug; 94():32-37. PubMed ID: 36309167
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Candy-Plug Technique: Technical Aspects and Early Results of a New Endovascular Method for False Lumen Occlusion in Chronic Aortic Dissection.
    Rohlffs F; Tsilimparis N; Fiorucci B; Heidemann F; Debus ES; Kölbel T
    J Endovasc Ther; 2017 Aug; 24(4):549-555. PubMed ID: 28490232
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Aortic Remodeling After Custom-Made Candy-Plug for Distal False Lumen Occlusion in Aortic Dissection.
    Eleshra A; Rohlffs F; Spanos K; Panuccio G; Heidemann F; Tsilimparis N; Kölbel T
    J Endovasc Ther; 2021 Jun; 28(3):399-406. PubMed ID: 33634714
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Candy-Plug Generation II for False Lumen Occlusion in Chronic Aortic Dissection: Feasibility and Early Results.
    Eleshra A; Kölbel T; Tsilimparis N; Panuccio G; Scheerbaum M; Debus ES; Mogensen J; Rohlffs F
    J Endovasc Ther; 2019 Dec; 26(6):782-786. PubMed ID: 31478456
    [No Abstract]   [Full Text] [Related]  

  • 10. False lumen embolization in chronic aortic dissection promotes thoracic aortic remodeling at midterm follow-up.
    Pellenc Q; Roussel A; De Blic R; Girault A; Cerceau P; Ben Abdallah I; Milleron O; Jondeau G; Castier Y
    J Vasc Surg; 2019 Sep; 70(3):710-717. PubMed ID: 30850289
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A modified candy-plug technique to occlude false lumen in aortic dissection.
    Palm E; Valtola A; Manninen H; Saari P
    CVIR Endovasc; 2022 Oct; 5(1):57. PubMed ID: 36308646
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Management of the False Lumen in Post Type A Aortic Dissection Arch Aneurysms Treated With Branched Endografts.
    Mougin J; Schwein A; Postiglione TJ; Guihaire J; Fabre D; Haulon S
    J Endovasc Ther; 2024 Oct; 31(5):927-935. PubMed ID: 36632664
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Homemade Candy Plug Using a Zenith Alpha Thoracic Stent-Graft for False Lumen Distal Occlusion in Acute-on-Chronic Type B Aortic Dissection.
    Yap KH; Tham YC; Tay KH; Tze Tec C; Irani FG; Kian CJ; Chao VTT
    J Endovasc Ther; 2019 Oct; 26(5):732-735. PubMed ID: 31257993
    [No Abstract]   [Full Text] [Related]  

  • 14. Candy-Plug Technique Using an Excluder Aortic Extender for Distal Occlusion of a Large False Lumen Aneurysm in Chronic Aortic Dissection.
    Ogawa Y; Nishimaki H; Chiba K; Murakami K; Sakurai Y; Fujiwara K; Miyairi T; Nakajima Y
    J Endovasc Ther; 2016 Jun; 23(3):483-6. PubMed ID: 27009975
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Aortic false lumen thrombosis induction by embolotherapy (AFTER) following endovascular repair of aortic dissection.
    Hofferberth SC; Nixon IK; Mossop PJ
    J Endovasc Ther; 2012 Aug; 19(4):538-45. PubMed ID: 22891838
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Methods and Outcomes of Endovascular False Lumen Embolization for Thoracic Aortic Dissection.
    Li HL; Chan YC; Jia HY; Cheng SW
    Ann Vasc Surg; 2022 Sep; 85():371-382. PubMed ID: 35339592
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of False Lumen Occlusion Treatment With AFX VELA
    Yasuhara K; Obayashi T; Ohki S; Okonogi S; Nagasawa A; Yamaguchi R; Kato Y; Miki T; Abe T
    Vasc Endovascular Surg; 2024 Jul; 58(5):505-511. PubMed ID: 38258617
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Staged Fenestrated/Branched Repair of Postdissecting Thoracoabdominal Aneurysm With Candy-Plug False Lumen Occlusion for Spinal Cord Preconditioning.
    Carta N; Salvati S; Melissano G; Chiesa R; Bertoglio L
    J Endovasc Ther; 2020 Apr; 27(2):221-227. PubMed ID: 32075487
    [No Abstract]   [Full Text] [Related]  

  • 19. Clinical Utility of the Candy-Plug Technique Using an Excluder Aortic Extender.
    Ogawa Y; Nishimaki H; Chiba K; Iraha T; Maruhashi T; Sakurai Y; Miyairi T; Nakajima Y
    Ann Vasc Dis; 2021 Jun; 14(2):139-145. PubMed ID: 34239639
    [No Abstract]   [Full Text] [Related]  

  • 20. Endovascular strategies for post-dissection aortic aneurysm (PDAA).
    Zeng Z; Zhao Y; Wu M; Bao X; Li T; Feng J; Feng R; Jing Z
    J Cardiothorac Surg; 2020 Oct; 15(1):287. PubMed ID: 33004048
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.