These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 38813393)

  • 1. Machine Perfusion Enables 24-h Preservation of Vascularized Composite Allografts in a Swine Model of Allotransplantation.
    Goutard M; Tawa P; Berkane Y; Andrews AR; Pendexter CA; de Vries RJ; Pozzo V; Romano G; Lancia HH; Filz von Reiterdank I; Bertheuil N; Rosales IA; How IDAL; Randolph MA; Lellouch AG; Cetrulo CL; Uygun K
    Transpl Int; 2024; 37():12338. PubMed ID: 38813393
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optimization of Ex Vivo Machine Perfusion and Transplantation of Vascularized Composite Allografts.
    Burlage LC; Lellouch AG; Taveau CB; Tratnig-Frankl P; Pendexter CA; Randolph MA; Porte RJ; Lantieri LA; Tessier SN; Cetrulo CL; Uygun K
    J Surg Res; 2022 Feb; 270():151-161. PubMed ID: 34670191
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Exceeding the Limits of Static Cold Storage in Limb Transplantation Using Subnormothermic Machine Perfusion.
    Goutard M; de Vries RJ; Tawa P; Pendexter CA; Rosales IA; Tessier SN; Burlage LC; Lantieri L; Randolph MA; Lellouch AG; Cetrulo CL; Uygun K
    J Reconstr Microsurg; 2023 Jun; 39(5):350-360. PubMed ID: 35764315
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sub-Zero Non-Freezing of Vascularized Composite Allografts Preservation in Rodents.
    von Reiterdank IF; Tawa P; Berkane Y; de Clermont-Tonnerre E; Dinicu A; Pendexter C; Goutard M; Lellouch AG; van der Molen ABM; Coert JH; Cetrulo CL; Uygun K
    Res Sq; 2023 Dec; ():. PubMed ID: 38234765
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Continuous versus Pulsatile Flow in 24-Hour Vascularized Composite Allograft Machine Perfusion in Swine: A Pilot Study.
    Tawa P; Goutard M; Andrews AR; de Vries RJ; Rosales IA; Yeh H; Uygun B; Randolph MA; Lellouch AG; Uygun K; Cetrulo CL
    J Surg Res; 2023 Mar; 283():1145-1153. PubMed ID: 36915006
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Advances in machine perfusion, organ preservation, and cryobiology: potential impact on vascularized composite allotransplantation.
    Burlage LC; Tessier SN; Etra JW; Uygun K; Brandacher G
    Curr Opin Organ Transplant; 2018 Oct; 23(5):561-567. PubMed ID: 30080697
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of a rat forelimb vascularized composite allograft (VCA) perfusion protocol.
    Pendexter CA; Haque O; Mojoudi M; Maggipinto S; Goutard M; Baicu S; Lellouch AG; Markmann JF; Brandacher G; Yeh H; Tessier SN; Cetrulo C; Uygun K
    PLoS One; 2023; 18(1):e0266207. PubMed ID: 36652460
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hypothermic Ex Situ Perfusion of Human Limbs With Acellular Solution for 24 Hours.
    Haug V; Kollar B; Tasigiorgos S; Endo Y; Kauke M; Safi AF; Veeramani A; Abdulrazzak O; Bausk B; Walt D; Pomahac B
    Transplantation; 2020 Sep; 104(9):e260-e270. PubMed ID: 32168040
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of Acellular Solutions for Ex-situ Perfusion of Amputated Limbs.
    Haug V; Kollar B; Endo Y; Kadakia N; Veeramani A; Kauke M; Tchiloemba B; Klasek R; Pomahac B
    Mil Med; 2020 Dec; 185(11-12):e2004-e2012. PubMed ID: 33377496
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of Subnormothermic Machine Perfusion on the Preservation of Vascularized Composite Allografts After Prolonged Warm Ischemia.
    Charlès L; Filz von Reiterdank I; Lancia HH; Shamlou AA; Berkane Y; Rosales I; Mink van der Molen AB; Coert JH; Cetrulo CL; Lellouch AG; Uygun K
    Transplantation; 2024 May; ():. PubMed ID: 38722685
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Large Animal Models of Vascularized Composite Allotransplantation: A Review of Immune Strategies to Improve Allograft Outcomes.
    Matar AJ; Crepeau RL; Mundinger GS; Cetrulo CL; Torabi R
    Front Immunol; 2021; 12():664577. PubMed ID: 34276656
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Randomized preclinical study of machine perfusion in vascularized composite allografts.
    Amin KR; Stone JP; Kerr J; Geraghty A; Joseph L; Montero-Fernandez A; Wong JK; Fildes JE
    Br J Surg; 2021 May; 108(5):574-582. PubMed ID: 34043778
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of Static Cold Storage on Skeletal Muscle after Vascularized Composite Tissue Allotransplantation.
    Gok E; Kubiak CA; Guy E; Kemp SWP; Ozer K
    J Reconstr Microsurg; 2020 Jan; 36(1):9-15. PubMed ID: 31302903
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Initial perfusate purification during subnormothermic machine perfusion for porcine liver donated after cardiac death.
    Obara H; Morito N; Matsuno N; Yoshikawa R; Nakajo T; Gochi M; Otani M; Shonaka T; Furukawa H; Hirano T; Enosawa S
    J Artif Organs; 2020 Mar; 23(1):62-69. PubMed ID: 31392524
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reduced Hypoxia-Related Genes in Porcine Limbs in Ex Vivo Hypothermic Perfusion Versus Cold Storage.
    Krezdorn N; Sakthivel D; Turk M; Aycart MA; Tasigiorgos S; Bueno EM; Sinha I; Pomahac B
    J Surg Res; 2018 Dec; 232():137-145. PubMed ID: 30463709
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improving the ischemia-reperfusion injury in vascularized composite allotransplantation: Clinical experience and experimental implications.
    He J; Khan UZ; Qing L; Wu P; Tang J
    Front Immunol; 2022; 13():998952. PubMed ID: 36189311
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design of a Multiparametric Perfusion Bioreactor System for Evaluating Sub-Normothermic Preservation of Rat Abdominal Wall Vascularized Composite Allografts.
    Salehi S; Lippert Lozano E; Zhang Y; Guo Y; Liu R; Tran K; Messner F; Brandacher G; Grayson WL
    Bioengineering (Basel); 2024 Mar; 11(4):. PubMed ID: 38671729
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impact of Machine Perfusion on Sinusoid Microcirculation of Liver Graft Donated After Cardiac Death.
    Kanazawa H; Obara H; Yoshikawa R; Meng L; Hirano T; Okada Y; Nishikawa Y; Matsuno N
    J Surg Res; 2020 Jan; 245():410-419. PubMed ID: 31437648
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of human-derived hemoglobin based oxygen vesicles as a machine perfusion solution for liver donation after cardiac death in a pig model.
    Shonaka T; Matsuno N; Obara H; Yoshikawa R; Nishikawa Y; Ishihara Y; Bochimoto H; Gochi M; Otani M; Kanazawa H; Azuma H; Sakai H; Furukawa H
    PLoS One; 2019; 14(12):e0226183. PubMed ID: 31825976
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Graft-implanted, enzyme responsive, tacrolimus-eluting hydrogel enables long-term survival of orthotopic porcine limb vascularized composite allografts: A proof of concept study.
    Fries CA; Lawson SD; Wang LC; Slaughter KV; Vemula PK; Dhayani A; Joshi N; Karp JM; Rickard RF; Gorantla VS; Davis MR
    PLoS One; 2019; 14(1):e0210914. PubMed ID: 30677062
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.