These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
113 related articles for article (PubMed ID: 38815565)
21. Complex dark-field contrast and its retrieval in x-ray phase contrast imaging implemented with Talbot interferometry. Yang Y; Tang X Med Phys; 2014 Oct; 41(10):101914. PubMed ID: 25281966 [TBL] [Abstract][Full Text] [Related]
22. Effect of dose metrics and radiation risk models when optimizing CT x-ray tube voltage. Huda W; Ogden KM; Khorasani MR Phys Med Biol; 2008 Sep; 53(17):4719-32. PubMed ID: 18695298 [TBL] [Abstract][Full Text] [Related]
23. Patient size and x-ray technique factors in head computed tomography examinations. II. Image quality. Huda W; Lieberman KA; Chang J; Roskopf ML Med Phys; 2004 Mar; 31(3):595-601. PubMed ID: 15070259 [TBL] [Abstract][Full Text] [Related]
24. Combining automated attenuation-based tube voltage selection and iterative reconstruction: a liver phantom study. Husarik DB; Schindera ST; Morsbach F; Chuck N; Seifert B; Szucs-Farkas Z; Alkadhi H Eur Radiol; 2014 Mar; 24(3):657-67. PubMed ID: 24154792 [TBL] [Abstract][Full Text] [Related]
25. Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media. Grant KL; Flohr TG; Krauss B; Sedlmair M; Thomas C; Schmidt B Invest Radiol; 2014 Sep; 49(9):586-92. PubMed ID: 24710203 [TBL] [Abstract][Full Text] [Related]
26. The upper limits of the SNR in radiography and CT with polyenergetic x-rays. Shikhaliev PM Phys Med Biol; 2010 Sep; 55(18):5317-39. PubMed ID: 20736493 [TBL] [Abstract][Full Text] [Related]
27. A four-grating interferometer for x-ray multi-contrast imaging. Miao H; Williams JC; Josell D Med Phys; 2024 May; 51(5):3648-3657. PubMed ID: 38558430 [TBL] [Abstract][Full Text] [Related]
28. Effect of x-ray tube parameters and iodine concentration on image quality and radiation dose in cerebral pediatric and adult CT angiography: a phantom study. Papadakis AE; Perisinakis K; Raissaki M; Damilakis J Invest Radiol; 2013 Apr; 48(4):192-9. PubMed ID: 23344518 [TBL] [Abstract][Full Text] [Related]
29. Image Quality Performance of Virtual Single-Source CT Using Dual-Source Computed Tomography. Alikhani B; Werner M; Jamali L; Wacker F; Werncke T Acad Radiol; 2019 Aug; 26(8):1095-1101. PubMed ID: 30482627 [TBL] [Abstract][Full Text] [Related]
30. Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom. Kang HJ; Lee JM; Lee SM; Yang HK; Kim RH; Nam JG; Karnawat A; Han JK BMC Med Imaging; 2019 Aug; 19(1):76. PubMed ID: 31462212 [TBL] [Abstract][Full Text] [Related]
31. Single-shot Talbot-Lau x-ray dark-field imaging of a porcine lung applying the moiré imaging approach. Seifert M; Ludwig V; Gallersdörfer M; Hauke C; Hellbach K; Horn F; Pelzer G; Radicke M; Rieger J; Sutter SM; Michel T; Anton G Phys Med Biol; 2018 Sep; 63(18):185010. PubMed ID: 30117437 [TBL] [Abstract][Full Text] [Related]
32. Contrast and quantum noise in single-exposure dual-energy thoracic imaging with photon-counting x-ray detectors. Dhari J; Tanguay J Phys Med Biol; 2024 Sep; 69(19):. PubMed ID: 39214125 [No Abstract] [Full Text] [Related]
33. Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape. Siegel MJ; Schmidt B; Bradley D; Suess C; Hildebolt C Radiology; 2004 Nov; 233(2):515-22. PubMed ID: 15358847 [TBL] [Abstract][Full Text] [Related]
34. Optimization of acquisition parameters for reduced-dose thoracic CT: A phantom study. Martini K; Moon JW; Revel MP; Dangeard S; Ruan C; Chassagnon G Diagn Interv Imaging; 2020 May; 101(5):269-279. PubMed ID: 32107196 [TBL] [Abstract][Full Text] [Related]
36. Fluence adaptation for contrast-based dose optimization in x-ray phase-contrast imaging. Wu C; Xing Y; Zhang L; Chen Z; Zhu X; Zhang X; Gao H Med Phys; 2021 Oct; 48(10):6106-6120. PubMed ID: 34432891 [TBL] [Abstract][Full Text] [Related]
37. A comparative study based on image quality and clinical task performance for CT reconstruction algorithms in radiotherapy. Li H; Dolly S; Chen HC; Anastasio MA; Low DA; Li HH; Michalski JM; Thorstad WL; Gay H; Mutic S J Appl Clin Med Phys; 2016 Jul; 17(4):377-390. PubMed ID: 27455472 [TBL] [Abstract][Full Text] [Related]
38. Development of X-ray phase CT with a hybrid configuration of Lau and Talbot-Lau interferometers. Kageyama M; Okajima K; Maesawa M; Nonoguchi M; Nonoguchi M; Kuribayashi M; Hara Y; Momose A J Xray Sci Technol; 2021; 29(1):63-73. PubMed ID: 33164981 [TBL] [Abstract][Full Text] [Related]
39. Task-based automatic keV selection: leveraging routine virtual monoenergetic imaging for dose reduction on clinical photon-counting detector CT Rajendran K; Bruesewitz M; Swicklik J; Ferrero A; Thorne J; Yu L; McCollough C; Leng S Phys Med Biol; 2024 May; 69(11):. PubMed ID: 38648795 [No Abstract] [Full Text] [Related]
40. Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience. Marin D; Nelson RC; Schindera ST; Richard S; Youngblood RS; Yoshizumi TT; Samei E Radiology; 2010 Jan; 254(1):145-53. PubMed ID: 20032149 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]