These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
124 related articles for article (PubMed ID: 38823678)
1. Optimal ultrasonic treatment frequency and duration parameters were used to detect the pathogenic bacteria of orthopedic implant-associated infection by ultrasonic oscillation. Xian C; Liu Y; Zhou L; Ding T; Chen J; Wang T; Gao J; Hao X; Bi L J Infect Chemother; 2024 Dec; 30(12):1237-1243. PubMed ID: 38823678 [TBL] [Abstract][Full Text] [Related]
2. Ultrasound frequency of sonication applied in microbiological diagnostics has a major impact on viability of bacteria causing PJI. Dudek P; Grajek A; Kowalczewski J; Madycki G; Marczak D Int J Infect Dis; 2020 Nov; 100():158-163. PubMed ID: 32827750 [TBL] [Abstract][Full Text] [Related]
3. Sonication of Extracted Implants Improves Microbial Detection in Patients With Orthopedic Implant-Associated Infections. Ueda N; Oe K; Nakamura T; Tsuta K; Iida H; Saito T J Arthroplasty; 2019 Jun; 34(6):1189-1196. PubMed ID: 30872034 [TBL] [Abstract][Full Text] [Related]
4. Concentration of Sonication Fluid through Centrifugation Is Superior to Membrane Filtration for Microbial Diagnosis of Orthopedic Implant-Associated Infection. Zitron R; Wajsfeld T; Klautau GB; da Silva CB; Nigro S; Mercadante MT; Polesello GC; Cury Rde P; Salles MJ J Clin Microbiol; 2016 Mar; 54(3):788-90. PubMed ID: 26719446 [TBL] [Abstract][Full Text] [Related]
5. Sonication of orthopaedic implants: A valuable technique for diagnosis of prosthetic joint infections. Sebastian S; Malhotra R; Sreenivas V; Kapil A; Chaudhry R; Dhawan B J Microbiol Methods; 2018 Mar; 146():51-54. PubMed ID: 29382603 [TBL] [Abstract][Full Text] [Related]
6. Implant Sonication versus Tissue Culture for the Diagnosis of Spinal Implant Infection. Carlson BC; Hines JT; Robinson WA; Sebastian AS; Greenwood-Quaintance KE; Patel R; Huddleston PM Spine (Phila Pa 1976); 2020 May; 45(9):E525-E532. PubMed ID: 32282655 [TBL] [Abstract][Full Text] [Related]
7. Shotgun sequencing of sonication fluid for the diagnosis of orthopaedic implant-associated infections with Ponraj DS; Lund M; Lange J; Poehlein A; Himmelbach A; Falstie-Jensen T; Jørgensen NP; Ravn C; Brüggemann H Front Cell Infect Microbiol; 2023; 13():1165017. PubMed ID: 37265503 [TBL] [Abstract][Full Text] [Related]
8. Sonication of Arthroplasty Implants Improves Accuracy of Periprosthetic Joint Infection Cultures. Rothenberg AC; Wilson AE; Hayes JP; O'Malley MJ; Klatt BA Clin Orthop Relat Res; 2017 Jul; 475(7):1827-1836. PubMed ID: 28290115 [TBL] [Abstract][Full Text] [Related]
9. Improved diagnosis of periprosthetic joint infection by multiplex PCR of sonication fluid from removed implants. Achermann Y; Vogt M; Leunig M; Wüst J; Trampuz A J Clin Microbiol; 2010 Apr; 48(4):1208-14. PubMed ID: 20164283 [TBL] [Abstract][Full Text] [Related]
10. Role of Sonication in the Microbiological Diagnosis of Implant-Associated Infections: Beyond the Orthopedic Prosthesis. Oliva A; Pavone P; D'Abramo A; Iannetta M; Mastroianni CM; Vullo V Adv Exp Med Biol; 2016; 897():85-102. PubMed ID: 26566645 [TBL] [Abstract][Full Text] [Related]
11. Role of Sonication for Detection of Infection in Explanted Orthopaedic Trauma Implants. Maniar HH; Wingert N; McPhillips K; Foltzer M; Graham J; Bowen TR; Horwitz DS J Orthop Trauma; 2016 May; 30(5):e175-80. PubMed ID: 27101168 [TBL] [Abstract][Full Text] [Related]
12. Prolonged incubation time does not increase sensitivity for the diagnosis of implant-related infection using samples prepared by sonication of the implants. Esteban J; Alvarez-Alvarez B; Blanco A; Fernández-Roblas R; Gadea I; Garcia-Cañete J; Sandoval E; Valdazo M Bone Joint J; 2013 Jul; 95-B(7):1001-6. PubMed ID: 23814257 [TBL] [Abstract][Full Text] [Related]
13. Clinically Asymptomatic Patients Show a High Bacterial Colonization Rate of Osteosynthetic Implants Around the Knee but Not the Hip. Fuchs M; Kinzel S; Gwinner C; Perka C; Renz N; von Roth P J Arthroplasty; 2019 Aug; 34(8):1761-1766. PubMed ID: 31064723 [TBL] [Abstract][Full Text] [Related]
14. Usefulness of sonication for diagnosing infection in explanted orthopaedic implants. Erivan R; Villatte G; Eymond G; Mulliez A; Descamps S; Boisgard S Orthop Traumatol Surg Res; 2018 Jun; 104(4):433-438. PubMed ID: 29355743 [TBL] [Abstract][Full Text] [Related]
15. Improved diagnosis of orthopedic implant-associated infection by inoculation of sonication fluid into blood culture bottles. Portillo ME; Salvadó M; Trampuz A; Siverio A; Alier A; Sorli L; Martínez S; Pérez-Prieto D; Horcajada JP; Puig-Verdie L J Clin Microbiol; 2015 May; 53(5):1622-7. PubMed ID: 25740775 [TBL] [Abstract][Full Text] [Related]
17. Brief ultrasonication improves detection of biofilm-formative bacteria around a metal implant. Kobayashi N; Bauer TW; Tuohy MJ; Fujishiro T; Procop GW Clin Orthop Relat Res; 2007 Apr; 457():210-3. PubMed ID: 17195819 [TBL] [Abstract][Full Text] [Related]
18. [Sonication in the diagnosis of periprosthetic infections : Significance and practical implementation]. Renz N; Cabric S; Janz V; Trampuz A Orthopade; 2015 Dec; 44(12):942-5. PubMed ID: 26572134 [TBL] [Abstract][Full Text] [Related]
19. Accurate and early diagnosis of orthopedic device-related infection by microbial heat production and sonication. Borens O; Yusuf E; Steinrücken J; Trampuz A J Orthop Res; 2013 Nov; 31(11):1700-3. PubMed ID: 23813873 [TBL] [Abstract][Full Text] [Related]