148 related articles for article (PubMed ID: 38827752)
1. Anterolateral Dual Plate Fixation for Distal Metaphyseal-Diaphyseal Junction Fractures of the Humerus: Biomechanical Finite Element Analysis with Clinical Results.
Ha C; Choi I; Lee JK; Oh J; Ahn W; Han SH
Clin Orthop Surg; 2024 Jun; 16(3):493-505. PubMed ID: 38827752
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: a finite element analysis.
Kong L; Wang Y; Lu Q; Han Y; Wang F
J Orthop Surg Res; 2021 Nov; 16(1):674. PubMed ID: 34784932
[TBL] [Abstract][Full Text] [Related]
3. Dual plating of humeral shaft fractures: orthogonal plates biomechanically outperform side-by-side plates.
Kosmopoulos V; Nana AD
Clin Orthop Relat Res; 2014 Apr; 472(4):1310-7. PubMed ID: 24218163
[TBL] [Abstract][Full Text] [Related]
4. Dual plate fixation on distal third diaphyseal fracture of the humerus.
Lee JK; Choi YS; Sim YS; Choi DS; Han SH
Int Orthop; 2017 Aug; 41(8):1655-1661. PubMed ID: 27909754
[TBL] [Abstract][Full Text] [Related]
5. Fractures of the distal humerus operated on using the Lambda® plate: report of 75 cases at 9.5 years follow-up.
Saragaglia D; Rouchy RC; Mercier N
Orthop Traumatol Surg Res; 2013 Oct; 99(6):707-12. PubMed ID: 24029585
[TBL] [Abstract][Full Text] [Related]
6. Modified pin and plate fixation for low intercondylar fractures of the humerus: biomechanical study corroborated with a case series.
Jitprapaikulsarn S; Chantarapanich N; Gromprasit A; Mahaisavariya C; Patamamongkonchai C
Musculoskelet Surg; 2023 Jun; 107(2):207-221. PubMed ID: 35362865
[TBL] [Abstract][Full Text] [Related]
7. A novel configuration for the fixation of intra-articular C2.3 distal humerus fractures with the potential for minimally invasive surgery: a biomechanical evaluation and finite element analysis.
Zhao W; Yuan H; Zhang Y; Guo Y; Basnet S; Li S; Li T; Liang B; Pei G
J Shoulder Elbow Surg; 2024 May; 33(5):1138-1149. PubMed ID: 37944743
[TBL] [Abstract][Full Text] [Related]
8. Dual small fragment plating improves screw-to-screw load sharing for mid-diaphyseal humeral fracture fixation: a finite element study.
Kosmopoulos V; Luedke C; Nana AD
Technol Health Care; 2015; 23(1):83-92. PubMed ID: 25408282
[TBL] [Abstract][Full Text] [Related]
9. Comparative study of mechanical performance of various fixation constructs in multifragmentary distal humeral shaft fracture: a finite element analysis.
Jitprapaikulsarn S; Chantarapanich N; Apivatthakakul T; Gromprasit A; Lertvilai P; Sukha K; Wanchat S; Mahaisavariya C
Eur J Orthop Surg Traumatol; 2024 Apr; 34(3):1287-1296. PubMed ID: 38071686
[TBL] [Abstract][Full Text] [Related]
10. Biomechanical effect of the configuration of screw hole style on locking plate fixation in proximal humerus fracture with a simulated gap: A finite element analysis.
Zhang YK; Wei HW; Lin KP; Chen WC; Tsai CL; Lin KJ
Injury; 2016 Jun; 47(6):1191-5. PubMed ID: 26975793
[TBL] [Abstract][Full Text] [Related]
11. Antero-lateral minimally invasive plate osteosynthesis (MIPO) with the radial nerve exploration for extra-articular distal-third diaphyseal fractures of the humerus.
Zhao W; Qu W; Fu C; Jiang H; Liu S; Cheng C
Int Orthop; 2017 Sep; 41(9):1757-1762. PubMed ID: 28577034
[TBL] [Abstract][Full Text] [Related]
12. Plate selection for fixation of extra-articular distal humerus fractures: a biomechanical comparison of three different implants.
Scolaro JA; Hsu JE; Svach DJ; Mehta S
Injury; 2014 Dec; 45(12):2040-4. PubMed ID: 25249244
[TBL] [Abstract][Full Text] [Related]
13. Lateral Subcutaneous Locking Compression Plate and Small Incision Reduction for Distal-third Diaphyseal Humerus Fractures.
Chang H; Yao ZL; Hou YL; Cao Y; Guo XH; Li GJ; Yu B
Orthop Surg; 2018 Aug; 10(3):218-226. PubMed ID: 30152611
[TBL] [Abstract][Full Text] [Related]
14. Comparative study of three models of extra-articular distal humerus fracture osteosynthesis using the finite element method on an osteoporotic computational model.
Sabalic S; Kodvanj J; Pavic A
Injury; 2013 Sep; 44 Suppl 3():S56-61. PubMed ID: 24060021
[TBL] [Abstract][Full Text] [Related]
15. Modified use of a proximal humeral internal locking system (PHILOS) plate in extra-articular distal-third diaphyseal humeral fractures.
Sohn HS; Shin SJ
Injury; 2019 Jul; 50(7):1300-1305. PubMed ID: 31178147
[TBL] [Abstract][Full Text] [Related]
16. [Biomechanical comparative study of three types of osteosynthesis in the treatment of supra and intercondylar fractures of the humerus in adults].
Fornasiéri C; Staub C; Tourné Y; Rumelhart C; Saragaglia D
Rev Chir Orthop Reparatrice Appar Mot; 1997; 83(3):237-42. PubMed ID: 9255359
[TBL] [Abstract][Full Text] [Related]
17. Long dorsal "Y-shaped" plate for distal diaphyseal humeral fractures.
Druel T; Burnier M; Herzberg G
Int Orthop; 2021 May; 45(5):1309-1314. PubMed ID: 33590258
[TBL] [Abstract][Full Text] [Related]
18. Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures.
Jeong JJ; Park SE; Lee HH; Ji JH; Park MS; Park YT
BMC Musculoskelet Disord; 2019 Aug; 20(1):381. PubMed ID: 31421675
[TBL] [Abstract][Full Text] [Related]
19. Comparative study of a Y- anatomical and innovative locking plate versus double plate for supracondylar humeral fracture.
Barret H; Ceccarelli R; D'Allais PV; Winter M; Chammas M; Coulet B; Lazerges C
Orthop Traumatol Surg Res; 2023 Sep; 109(5):103380. PubMed ID: 35908734
[TBL] [Abstract][Full Text] [Related]
20. AO extra-articular distal humerus locking plate: extended spectrum of usage in intra-articular distal fractures with metaphyseal extension--our experience with 20 cases.
Aggarwal S; Kumar V; Bhagwat KR; Behera P
Eur J Orthop Surg Traumatol; 2014 May; 24(4):505-11. PubMed ID: 23563623
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]