156 related articles for article (PubMed ID: 38827752)
21. Clinical outcomes of dual 3.5-mm locking compression plate fixation for humeral shaft fractures: Comparison with single 4.5-mm locking compression plate fixation.
Seo JB; Heo K; Yang JH; Yoo JS
J Orthop Surg (Hong Kong); 2019; 27(2):2309499019839608. PubMed ID: 30955460
[TBL] [Abstract][Full Text] [Related]
22. Bi-columnar locking plate fixation through a combined medial and lateral approach for the treatment of low transcondylar fractures of the distal humerus in the elderly.
Park SG; Seok HG
BMC Musculoskelet Disord; 2022 Aug; 23(1):764. PubMed ID: 35948886
[TBL] [Abstract][Full Text] [Related]
23. [Functional results of the parallel-plate technique for complex distal humerus fractures].
Atalar AC; Demirhan M; Salduz A; Kiliçoğlu O; Seyahi A
Acta Orthop Traumatol Turc; 2009; 43(1):21-7. PubMed ID: 19293612
[TBL] [Abstract][Full Text] [Related]
24. Surgical result of plate osteosynthesis using a locking plate system through an anterior humeral approach for distal shaft fracture of the humerus that occurred during a throwing motion.
Kim SJ; Lee SH; Son H; Lee BG
Int Orthop; 2016 Jul; 40(7):1489-94. PubMed ID: 26202018
[TBL] [Abstract][Full Text] [Related]
25. Comparison between anterior and posterior plating systems in extra-articular distal-third diaphyseal humeral fractures.
Shin SJ; Kwak JW; Sohn HS
Int Orthop; 2022 Sep; 46(9):2119-2126. PubMed ID: 35575805
[TBL] [Abstract][Full Text] [Related]
26. Less invasive plate osteosynthesis in humeral shaft fractures.
Apivatthakakul T; Phornphutkul C; Laohapoonrungsee A; Sirirungruangsarn Y
Oper Orthop Traumatol; 2009 Dec; 21(6):602-13. PubMed ID: 20087720
[TBL] [Abstract][Full Text] [Related]
27. Mechanical stability study of three techniques used in the fixation of transverse and oblique metaphyseal-diaphyseal junction fractures of the distal humerus in children: a finite element analysis.
Liu C; Kamara A; Liu T; Yan Y; Wang E
J Orthop Surg Res; 2020 Jan; 15(1):34. PubMed ID: 32020882
[TBL] [Abstract][Full Text] [Related]
28. LCP metaphyseal plate fixation for fractures of the distal third humeral shaft using brachialis splitting approach.
Lee SK; Yang DS; Chang SH; Choy WS
Acta Orthop Belg; 2016 Mar; 82(1):85-93. PubMed ID: 26984659
[TBL] [Abstract][Full Text] [Related]
29. Use of a "hybrid" locking plate for complex metaphyseal fractures and nonunions about the humerus.
Spitzer AB; Davidovitch RI; Egol KA
Injury; 2009 Mar; 40(3):240-4. PubMed ID: 19195653
[TBL] [Abstract][Full Text] [Related]
30. Length of Plates and Number of Screws for the Fixation of Distal Humerus Fractures: A Finite Element Biomechanical Study.
Zarifian A; Akbarinezhad Fough A; Eygendaal D; Rivlin M; Mousavi Shaegh SA; Kachooei AR
J Hand Surg Am; 2022 Jul; 47(7):690.e1-690.e11. PubMed ID: 34474947
[TBL] [Abstract][Full Text] [Related]
31. Biomechanical evaluation of parallel versus orthogonal plate fixation of intra-articular distal humerus fractures.
Zalavras CG; Vercillo MT; Jun BJ; Otarodifard K; Itamura JM; Lee TQ
J Shoulder Elbow Surg; 2011 Jan; 20(1):12-20. PubMed ID: 21134662
[TBL] [Abstract][Full Text] [Related]
32. Three-dimensional printing designed customized plate in the treatment of coronal fracture of distal humerus in teenager: A case report.
Cao C; Xing H; Cao F; Du Z; Wang G; Wang X
Medicine (Baltimore); 2023 Jan; 102(2):e32507. PubMed ID: 36637956
[TBL] [Abstract][Full Text] [Related]
33. Outcomes of distal humerus diaphyseal injuries fixed with a single-column anatomic plate.
Capo JT; Debkowska MP; Liporace F; Beutel BG; Melamed E
Int Orthop; 2014 May; 38(5):1037-43. PubMed ID: 24337886
[TBL] [Abstract][Full Text] [Related]
34. Medial approach to treat humeral mid-shaft fractures: a retrospective study.
Lu S; Wu J; Xu S; Fu B; Dong J; Yang Y; Wang G; Xin M; Li Q; He TC; Wang F; Zhou D
J Orthop Surg Res; 2016 Mar; 11():32. PubMed ID: 26988227
[TBL] [Abstract][Full Text] [Related]
35. Biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis.
Lee JS; Kim KG; Yoon YC
Sci Rep; 2023 Sep; 13(1):16250. PubMed ID: 37758839
[TBL] [Abstract][Full Text] [Related]
36. Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture.
Jung SW; Kang SH; Jeong M; Lim HS
Clin Orthop Surg; 2016 Mar; 8(1):9-18. PubMed ID: 26929794
[TBL] [Abstract][Full Text] [Related]
37. Functional outcome of extra-articular distal humerus fracture fixation using a single locking plate: A retrospective study.
Trikha V; Agrawal P; Das S; Gaba S; Kumar A
J Orthop Surg (Hong Kong); 2017; 25(3):2309499017727948. PubMed ID: 28844197
[TBL] [Abstract][Full Text] [Related]
38. [Operative effect and treatment strategies for the low distal humerus fracture].
Fan J; Ji JQ; Zhang X; Guo XW; Yao Y; Zhou JQ; Li SZ; Yuan F; Yu GR; Cheng LM
Zhonghua Wai Ke Za Zhi; 2020 Mar; 58(3):213-219. PubMed ID: 32187925
[No Abstract] [Full Text] [Related]
39. Outcome after open reduction and angular stable internal fixation for supra-intercondylar fractures of the distal humerus: preliminary results with the LCP distal humerus system.
Greiner S; Haas NP; Bail HJ
Arch Orthop Trauma Surg; 2008 Jul; 128(7):723-9. PubMed ID: 17713771
[TBL] [Abstract][Full Text] [Related]
40. Functional outcomes of minimal invasive percutaneous plate osteosynthesis (MIPPO) in humerus shaft fractures: a clinical study.
Huri G; Biçer ÖS; Öztürk H; Deveci MA; Tan I
Acta Orthop Traumatol Turc; 2014; 48(4):406-12. PubMed ID: 25230263
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]