BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 38827752)

  • 21. Clinical outcomes of dual 3.5-mm locking compression plate fixation for humeral shaft fractures: Comparison with single 4.5-mm locking compression plate fixation.
    Seo JB; Heo K; Yang JH; Yoo JS
    J Orthop Surg (Hong Kong); 2019; 27(2):2309499019839608. PubMed ID: 30955460
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Bi-columnar locking plate fixation through a combined medial and lateral approach for the treatment of low transcondylar fractures of the distal humerus in the elderly.
    Park SG; Seok HG
    BMC Musculoskelet Disord; 2022 Aug; 23(1):764. PubMed ID: 35948886
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Functional results of the parallel-plate technique for complex distal humerus fractures].
    Atalar AC; Demirhan M; Salduz A; Kiliçoğlu O; Seyahi A
    Acta Orthop Traumatol Turc; 2009; 43(1):21-7. PubMed ID: 19293612
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Surgical result of plate osteosynthesis using a locking plate system through an anterior humeral approach for distal shaft fracture of the humerus that occurred during a throwing motion.
    Kim SJ; Lee SH; Son H; Lee BG
    Int Orthop; 2016 Jul; 40(7):1489-94. PubMed ID: 26202018
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison between anterior and posterior plating systems in extra-articular distal-third diaphyseal humeral fractures.
    Shin SJ; Kwak JW; Sohn HS
    Int Orthop; 2022 Sep; 46(9):2119-2126. PubMed ID: 35575805
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Less invasive plate osteosynthesis in humeral shaft fractures.
    Apivatthakakul T; Phornphutkul C; Laohapoonrungsee A; Sirirungruangsarn Y
    Oper Orthop Traumatol; 2009 Dec; 21(6):602-13. PubMed ID: 20087720
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Mechanical stability study of three techniques used in the fixation of transverse and oblique metaphyseal-diaphyseal junction fractures of the distal humerus in children: a finite element analysis.
    Liu C; Kamara A; Liu T; Yan Y; Wang E
    J Orthop Surg Res; 2020 Jan; 15(1):34. PubMed ID: 32020882
    [TBL] [Abstract][Full Text] [Related]  

  • 28. LCP metaphyseal plate fixation for fractures of the distal third humeral shaft using brachialis splitting approach.
    Lee SK; Yang DS; Chang SH; Choy WS
    Acta Orthop Belg; 2016 Mar; 82(1):85-93. PubMed ID: 26984659
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Use of a "hybrid" locking plate for complex metaphyseal fractures and nonunions about the humerus.
    Spitzer AB; Davidovitch RI; Egol KA
    Injury; 2009 Mar; 40(3):240-4. PubMed ID: 19195653
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Length of Plates and Number of Screws for the Fixation of Distal Humerus Fractures: A Finite Element Biomechanical Study.
    Zarifian A; Akbarinezhad Fough A; Eygendaal D; Rivlin M; Mousavi Shaegh SA; Kachooei AR
    J Hand Surg Am; 2022 Jul; 47(7):690.e1-690.e11. PubMed ID: 34474947
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Biomechanical evaluation of parallel versus orthogonal plate fixation of intra-articular distal humerus fractures.
    Zalavras CG; Vercillo MT; Jun BJ; Otarodifard K; Itamura JM; Lee TQ
    J Shoulder Elbow Surg; 2011 Jan; 20(1):12-20. PubMed ID: 21134662
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Three-dimensional printing designed customized plate in the treatment of coronal fracture of distal humerus in teenager: A case report.
    Cao C; Xing H; Cao F; Du Z; Wang G; Wang X
    Medicine (Baltimore); 2023 Jan; 102(2):e32507. PubMed ID: 36637956
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Outcomes of distal humerus diaphyseal injuries fixed with a single-column anatomic plate.
    Capo JT; Debkowska MP; Liporace F; Beutel BG; Melamed E
    Int Orthop; 2014 May; 38(5):1037-43. PubMed ID: 24337886
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Medial approach to treat humeral mid-shaft fractures: a retrospective study.
    Lu S; Wu J; Xu S; Fu B; Dong J; Yang Y; Wang G; Xin M; Li Q; He TC; Wang F; Zhou D
    J Orthop Surg Res; 2016 Mar; 11():32. PubMed ID: 26988227
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis.
    Lee JS; Kim KG; Yoon YC
    Sci Rep; 2023 Sep; 13(1):16250. PubMed ID: 37758839
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture.
    Jung SW; Kang SH; Jeong M; Lim HS
    Clin Orthop Surg; 2016 Mar; 8(1):9-18. PubMed ID: 26929794
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Functional outcome of extra-articular distal humerus fracture fixation using a single locking plate: A retrospective study.
    Trikha V; Agrawal P; Das S; Gaba S; Kumar A
    J Orthop Surg (Hong Kong); 2017; 25(3):2309499017727948. PubMed ID: 28844197
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Operative effect and treatment strategies for the low distal humerus fracture].
    Fan J; Ji JQ; Zhang X; Guo XW; Yao Y; Zhou JQ; Li SZ; Yuan F; Yu GR; Cheng LM
    Zhonghua Wai Ke Za Zhi; 2020 Mar; 58(3):213-219. PubMed ID: 32187925
    [No Abstract]   [Full Text] [Related]  

  • 39. Outcome after open reduction and angular stable internal fixation for supra-intercondylar fractures of the distal humerus: preliminary results with the LCP distal humerus system.
    Greiner S; Haas NP; Bail HJ
    Arch Orthop Trauma Surg; 2008 Jul; 128(7):723-9. PubMed ID: 17713771
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Functional outcomes of minimal invasive percutaneous plate osteosynthesis (MIPPO) in humerus shaft fractures: a clinical study.
    Huri G; Biçer ÖS; Öztürk H; Deveci MA; Tan I
    Acta Orthop Traumatol Turc; 2014; 48(4):406-12. PubMed ID: 25230263
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.