130 related articles for article (PubMed ID: 38828067)
1. Dosimetric Evaluation of Semiflex Three-dimensional Chamber under Unflatten Beam in Comparison among Different Detectors.
Kandasamy K; Samuel EJJ
J Med Phys; 2024; 49(1):84-94. PubMed ID: 38828067
[TBL] [Abstract][Full Text] [Related]
2. MO-A-BRB-02: Facts and Fiction of Flattening Filter Free (FF-FFF) X-Rays Beams.
Ting J
Med Phys; 2012 Jun; 39(6Part20):3861-3862. PubMed ID: 28517518
[TBL] [Abstract][Full Text] [Related]
3. [Measurement of peak correction factor of Farmer chamber for calibration of flattening filter free (FFF) clinical photon beams].
Kontra G; Major T; Polgár C
Magy Onkol; 2015 Jun; 59(2):119-23. PubMed ID: 26035159
[TBL] [Abstract][Full Text] [Related]
4. Evaluation and Comparison of Dosimetric Characteristics of Semiflex
Momeni Harzanji Z; Larizadeh MH; Namiranian N; Nickfarjam A
J Biomed Phys Eng; 2022 Oct; 12(5):477-488. PubMed ID: 36313410
[TBL] [Abstract][Full Text] [Related]
5. An evaluation of solid state detectors for the relative dosimetry of kilovoltage X-ray beams.
Daniel J; Yousif YAM; Zifodya J; Hill R
Med Phys; 2022 Jun; 49(6):4082-4091. PubMed ID: 35179232
[TBL] [Abstract][Full Text] [Related]
6. Effect of angular dependence for small-field dosimetry using seven different detectors.
Kawata K; Ono T; Hirashima H; Tsuruta Y; Fujimoto T; Nakamura M; Nakata M
Med Phys; 2023 Mar; 50(3):1274-1289. PubMed ID: 36583601
[TBL] [Abstract][Full Text] [Related]
7. Dosimetric characterization of a novel commercial plastic scintillation detector with an MR-Linac.
Ferrer C; Huertas C; García D; Sáez M
Med Phys; 2023 Apr; 50(4):2525-2539. PubMed ID: 36611266
[TBL] [Abstract][Full Text] [Related]
8. Commissioning and dosimetric characteristics of TrueBeam system: composite data of three TrueBeam machines.
Chang Z; Wu Q; Adamson J; Ren L; Bowsher J; Yan H; Thomas A; Yin FF
Med Phys; 2012 Nov; 39(11):6981-7018. PubMed ID: 23127092
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of scanning resolution, detector choice and detector orientation to be used for accurate and time-efficient commissioning of a 6MV clinical linear accelerator.
Azhar D; Gul A; Javid MA; Hussain MM; Shehzadi NN
Radiat Environ Biophys; 2023 Mar; 62(1):83-96. PubMed ID: 36520198
[TBL] [Abstract][Full Text] [Related]
10. Beam characteristics of energy-matched flattening filter free beams.
Paynter D; Weston SJ; Cosgrove VP; Evans JA; Thwaites DI
Med Phys; 2014 May; 41(5):052103. PubMed ID: 24784392
[TBL] [Abstract][Full Text] [Related]
11. Dosimetric characteristics of the novel 2D ionization chamber array OCTAVIUS Detector 1500.
Stelljes TS; Harmeyer A; Reuter J; Looe HK; Chofor N; Harder D; Poppe B
Med Phys; 2015 Apr; 42(4):1528-37. PubMed ID: 25832043
[TBL] [Abstract][Full Text] [Related]
12. Clinical radiation therapy measurements with a new commercial synthetic single crystal diamond detector.
Laub WU; Crilly R
J Appl Clin Med Phys; 2014 Nov; 15(6):4890. PubMed ID: 25493512
[TBL] [Abstract][Full Text] [Related]
13. Characteristics of flattening filter free beams at low monitor unit settings.
Akino Y; Ota S; Inoue S; Mizuno H; Sumida I; Yoshioka Y; Isohashi F; Ogawa K
Med Phys; 2013 Nov; 40(11):112101. PubMed ID: 24320454
[TBL] [Abstract][Full Text] [Related]
14. Evaluating dosimetric accuracy of flattening filter free compensator-based IMRT: measurements with diode arrays.
Robinson J; Opp D; Zhang G; Cashon K; Kozelka J; Hunt D; Walker L; Hoffe S; Shridhar R; Feygelman V
Med Phys; 2012 Jan; 39(1):342-52. PubMed ID: 22225304
[TBL] [Abstract][Full Text] [Related]
15. Impact of detector selections on inter-institutional variability of flattening filter-free beam data for TrueBeam™ linear accelerators.
Tanaka Y; Akino Y; Mizuno H; Isono M; Masai N; Yamamoto T
J Appl Clin Med Phys; 2020 Jan; 21(1):36-42. PubMed ID: 31738002
[TBL] [Abstract][Full Text] [Related]
16. A novel method for the determination of field output factors and output correction factors for small static fields for six diodes and a microdiamond detector in megavoltage photon beams.
Casar B; Gershkevitsh E; Mendez I; Jurković S; Huq MS
Med Phys; 2019 Feb; 46(2):944-963. PubMed ID: 30521073
[TBL] [Abstract][Full Text] [Related]
17. Relative dosimetry with an MR-linac: Response of ion chambers, diamond, and diode detectors for off-axis, depth dose, and output factor measurements.
O'Brien DJ; Dolan J; Pencea S; Schupp N; Sawakuchi GO
Med Phys; 2018 Feb; 45(2):884-897. PubMed ID: 29178457
[TBL] [Abstract][Full Text] [Related]
18. Small field detector correction factors: effects of the flattening filter for Elekta and Varian linear accelerators.
Tyler MK; Liu PZ; Lee C; McKenzie DR; Suchowerska N
J Appl Clin Med Phys; 2016 May; 17(3):223-235. PubMed ID: 27167280
[TBL] [Abstract][Full Text] [Related]
19. Technical Note: An alternative approach to verify 6FFF beam dosimetry for Ethos and MR Linac without using a 3D water tank.
Hao Y; Cai B; Green O; Knutson N; Yaddanapudi S; Zhao T; Rodriguez V; Schmidt M; Mutic S; Sun B
Med Phys; 2021 Apr; 48(4):1533-1539. PubMed ID: 33547684
[TBL] [Abstract][Full Text] [Related]
20. Technical note: Point-by-point ion-recombination correction for accurate dose profile measurement in high dose-per-pulse irradiation field.
Kojima H; Ishikawa M; Takigami M
Med Phys; 2023 Nov; 50(11):7281-7293. PubMed ID: 37528637
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]