These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 38829157)

  • 1. Experimental investigation of a Tonpilz transducer operating in the frequency band of 20-80 kHz (L).
    Ji B; Lan Y; Qiao G; Shao S
    J Acoust Soc Am; 2024 Jun; 155(6):3600-3603. PubMed ID: 38829157
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bandwidth extension of the Tonpilz transducer using high-order longitudinal vibrations.
    Ji B; Lan Y; Qiao G; Wang M
    J Acoust Soc Am; 2023 Dec; 154(6):3709-3725. PubMed ID: 38088746
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design of a Wideband Tonpilz Transducer Comprising Non-Uniform Piezoceramic Stacks with Equivalent Circuits.
    Pyo S; Afzal MS; Lim Y; Lee S; Roh Y
    Sensors (Basel); 2021 Apr; 21(8):. PubMed ID: 33920252
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A wideband tonpilz transducer with a transverse through-hole in the radiating head.
    He X; Zhu X; Wu Z; Kang X; Wang Y
    J Acoust Soc Am; 2021 Oct; 150(4):2655. PubMed ID: 34717510
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influences of length and position of drive-stacks on the transmitting-voltage-response of the broadband Tonpilz transducer.
    Ji B; Hong L; Lan Y
    J Acoust Soc Am; 2021 Dec; 150(6):4140. PubMed ID: 34972275
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Equivalent circuit for analyzing the transmitting characteristics of multimode Tonpilz transducer.
    Pyo S; Roh Y
    J Acoust Soc Am; 2022 Jun; 151(6):3594. PubMed ID: 35778183
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance of tonpilz transducers with segmented piezoelectric stacks using materials with high electromechanical coupling coefficient.
    Thompson SC; Meyer RJ; Markley DC
    J Acoust Soc Am; 2014 Jan; 135(1):155-64. PubMed ID: 24437755
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modeling and Design of a Rear-Mounted Underwater Projector Using Equivalent Circuits.
    Kim J; Roh Y
    Sensors (Basel); 2020 Dec; 20(24):. PubMed ID: 33321916
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance of a low-frequency, multi-resonant broadband Tonpilz transducer.
    Rajapan D
    J Acoust Soc Am; 2002 Apr; 111(4):1692-4. PubMed ID: 12002852
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Spherical-Omnidirectional Piezoelectric Composite Transducer for High- Frequency Underwater Acoustics.
    Zhang Y; Wang L; Qin L; Zhong C; Hao S
    IEEE Trans Ultrason Ferroelectr Freq Control; 2021 May; 68(5):1791-1796. PubMed ID: 33275579
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design and calibration of a Tonpilz transducer for low frequency medical ultrasound tomography.
    Pigatto AV; Giacobbo L; Lisibach A; Filho EML; Lima RG; Mueller JL
    Annu Int Conf IEEE Eng Med Biol Soc; 2022 Jul; 2022():4611-4617. PubMed ID: 36086323
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Research and Fabrication of Broadband Ring Flextensional Underwater Transducer.
    Hu J; Hong L; Yin L; Lan Y; Sun H; Guo R
    Sensors (Basel); 2021 Feb; 21(4):. PubMed ID: 33672243
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Finite Element Calculation with Experimental Verification for a Free-Flooded Transducer Based on Fluid Cavity Structure.
    He Z; Chen G; Wang Y; Zhang K; Tian W
    Sensors (Basel); 2018 Sep; 18(9):. PubMed ID: 30227615
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of measured acoustic power results gained by using three different methods on an ultrasonic low-frequency device.
    Petosić A; Svilar D; Ivancević B
    Ultrason Sonochem; 2011 Mar; 18(2):567-76. PubMed ID: 20850368
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigation of a new wide-band transducer with piezoelectric layered ring.
    Yuan Y
    IEEE Trans Ultrason Ferroelectr Freq Control; 1992; 39(1):39-42. PubMed ID: 18263116
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultra-wide operation band of the high-frequency underwater acoustic transducer realized by two-layer 1-3 piezoelectric composite.
    Ji B; Hong L; Lan Y
    J Acoust Soc Am; 2021 Nov; 150(5):3474. PubMed ID: 34852600
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Wideband and Wide Beam Polyvinylidene Difluoride (PVDF) Acoustic Transducer for Broadband Underwater Communications.
    Martins MS; Faria CL; Matos T; Goncalves LM; Cabral J; Silva A; Jesus SM
    Sensors (Basel); 2019 Sep; 19(18):. PubMed ID: 31527406
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Normative Wideband Reflectance, Equivalent Admittance at the Tympanic Membrane, and Acoustic Stapedius Reflex Threshold in Adults.
    Feeney MP; Keefe DH; Hunter LL; Fitzpatrick DF; Garinis AC; Putterman DB; McMillan GP
    Ear Hear; 2017; 38(3):e142-e160. PubMed ID: 28045835
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Design optimization of wide-band Tonpilz piezoelectric transducer with a bending piezoelectric disk on the radiation surface.
    Saijyou K; Okuyama T
    J Acoust Soc Am; 2010 May; 127(5):2836-46. PubMed ID: 21117734
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tonpilz-type vector sensor for the estimation of underwater sound wave direction.
    Roh Y; Lim Y
    J Acoust Soc Am; 2018 Nov; 144(5):2801. PubMed ID: 30522280
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.