These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 38833160)

  • 41. The tribology (friction, lubrication and wear) of all-metal artificial hip joints. 1971.
    Walker PS; Gold BL
    Clin Orthop Relat Res; 1996 Aug; (329 Suppl):S4-10. PubMed ID: 8769319
    [No Abstract]   [Full Text] [Related]  

  • 42. Alternative bearing surface options for revision total hip arthroplasty.
    Patel D; Parvizi J; Sharkey PF
    Instr Course Lect; 2011; 60():257-67. PubMed ID: 21553778
    [TBL] [Abstract][Full Text] [Related]  

  • 43. In-situ electrochemical study of interaction of tribology and corrosion in artificial hip prosthesis simulators.
    Yan Y; Dowson D; Neville A
    J Mech Behav Biomed Mater; 2013 Feb; 18():191-9. PubMed ID: 23182693
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Friction of ceramic and metal hip hemi-endoprostheses against cadaveric acetabula.
    Müller LP; Degreif J; Rudig L; Mehler D; Hely H; Rommens PM
    Arch Orthop Trauma Surg; 2004 Dec; 124(10):681-7. PubMed ID: 15449077
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Design aspects of compliant, soft layer bearings for an experimental hip prosthesis.
    Scholes SC; Unsworth A; Blamey JM; Burgess IC; Jones E; Smith N
    Proc Inst Mech Eng H; 2005; 219(2):79-87. PubMed ID: 15819479
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Metallographic evaluation of hip joint implants wear and electrochemical implants potential.
    Kmieć K; Sibinski M; Synder M; Drobniewski M; Kozłowski P
    Hip Int; 2014 Dec; 24(6):604-9. PubMed ID: 25362874
    [TBL] [Abstract][Full Text] [Related]  

  • 47. [Total Joint Replacement and Return to Sports].
    Oehler N; Schmidt T; Niemeier A
    Sportverletz Sportschaden; 2016 Dec; 30(4):195-203. PubMed ID: 27984831
    [No Abstract]   [Full Text] [Related]  

  • 48. Understanding the role of corrosion in the degradation of metal-on-metal implants.
    Yan Y; Neville A; Dowson D
    Proc Inst Mech Eng H; 2006 Feb; 220(2):173-81. PubMed ID: 16669385
    [TBL] [Abstract][Full Text] [Related]  

  • 49. The relation between titanium taper corrosion and cobalt-chromium bearing wear in large-head metal-on-metal total hip prostheses: a retrieval study.
    Witt F; Bosker BH; Bishop NE; Ettema HB; Verheyen CC; Morlock MM
    J Bone Joint Surg Am; 2014 Sep; 96(18):e157. PubMed ID: 25232087
    [TBL] [Abstract][Full Text] [Related]  

  • 50. The effect of 'running-in' on the tribology and surface morphology of metal-on-metal Birmingham hip resurfacing device in simulator studies.
    Vassiliou K; Elfick AP; Scholes SC; Unsworth A
    Proc Inst Mech Eng H; 2006 Feb; 220(2):269-77. PubMed ID: 16669393
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Adaptive multimode lubrication in natural synovial joints and artificial joints.
    Murakami T; Higaki H; Sawae Y; Ohtsuki N; Moriyama S; Nakanishi Y
    Proc Inst Mech Eng H; 1998; 212(1):23-35. PubMed ID: 9529934
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Simultaneous measurement of friction and wear in hip simulators.
    Haider H; Weisenburger JN; Garvin KL
    Proc Inst Mech Eng H; 2016 May; 230(5):373-88. PubMed ID: 27160558
    [TBL] [Abstract][Full Text] [Related]  

  • 53. [The Role of a Modular Universal Tumour and Revision System (MUTARS®) in Lower Limb Endoprosthetic Revision Surgery - Outcome Analysis of 25 Patients].
    Schmolders J; Koob S; Schepers P; Gravius S; Wirtz DC; Burger C; Pennekamp PH; Strauss AC
    Z Orthop Unfall; 2017 Feb; 155(1):61-66. PubMed ID: 27632667
    [No Abstract]   [Full Text] [Related]  

  • 54. Compliant layer acetabular cups: friction testing of a range of materials and designs for a new generation of prosthesis that mimics the natural joint.
    Scholes SC; Burgess IC; Marsden HR; Unsworth A; Jones E; Smith N
    Proc Inst Mech Eng H; 2006 Jul; 220(5):583-96. PubMed ID: 16898216
    [TBL] [Abstract][Full Text] [Related]  

  • 55. The wear of metal-on-metal total hip prostheses measured in a hip simulator.
    Scholes SC; Green SM; Unsworth A
    Proc Inst Mech Eng H; 2001; 215(6):523-30. PubMed ID: 11848384
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.
    Williams S; Butterfield M; Stewart T; Ingham E; Stone M; Fisher J
    Proc Inst Mech Eng H; 2003; 217(2):147-53. PubMed ID: 12666782
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Incorporating corrosion measurement in hip wear simulators: An added complication or a necessity?
    Neville A; Hesketh J; Beadling AR; Bryant MG; Dowson D
    Proc Inst Mech Eng H; 2016 May; 230(5):406-20. PubMed ID: 27160560
    [TBL] [Abstract][Full Text] [Related]  

  • 58. [Investigations on tribology and strength of aluminium-oxide-ceramic--hip endoprostheses (author's transl)].
    Hinterberger J; Ungethüm M
    Z Orthop Ihre Grenzgeb; 1978; 116(3):285-303. PubMed ID: 685383
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Lubrication regimes in lumbar total disc arthroplasty.
    Shaheen A; Shepherd DE
    Proc Inst Mech Eng H; 2007 Aug; 221(6):621-7. PubMed ID: 17937201
    [TBL] [Abstract][Full Text] [Related]  

  • 60. [Arthroplasty of the metacarpophalangeal joint using pyrocarbonate implants].
    Beckenbaugh RD
    Orthopade; 2003 Sep; 32(9):794-7. PubMed ID: 14508645
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.