127 related articles for article (PubMed ID: 38834264)
1. Novel electrospun-based extractive probes for rapid determination of clinically important compounds in human plasma.
Temel ER; Eroğlu AE; Salih B; Boyaci E
Anal Chim Acta; 2024 Jul; 1312():342750. PubMed ID: 38834264
[TBL] [Abstract][Full Text] [Related]
2. Development and functionalization of electrospun fiber coated thin film microextraction devices for rapid mass spectrometric determination of biologically important polar molecules.
Öztürk M; Salih B; Eroğlu AE; Boyaci E
J Pharm Biomed Anal; 2024 Jun; 243():116074. PubMed ID: 38437785
[TBL] [Abstract][Full Text] [Related]
3. Development of coatings for automated 96-blade solid phase microextraction-liquid chromatography-tandem mass spectrometry system, capable of extracting a wide polarity range of analytes from biological fluids.
Mirnaghi FS; Pawliszyn J
J Chromatogr A; 2012 Oct; 1261():91-8. PubMed ID: 22824218
[TBL] [Abstract][Full Text] [Related]
4. Coated blade spray: shifting the paradigm of direct sample introduction to MS.
Gómez-Ríos GA; Tascon M; Pawliszyn J
Bioanalysis; 2018 Feb; 10(4):257-271. PubMed ID: 29376744
[TBL] [Abstract][Full Text] [Related]
5. Rapid Screening and Quantitation of Drugs of Abuse by Both Positive and Negative Modes via Coated Blade Spray-Mass Spectrometry.
Zhou W; Nazdrajić E; Pawliszyn J
J Am Soc Mass Spectrom; 2022 Jul; 33(7):1187-1193. PubMed ID: 35609124
[TBL] [Abstract][Full Text] [Related]
6. Electrospun fibrous thin film microextraction coupled with desorption corona beam ionization-mass spectrometry for rapid analysis of antidepressants in human plasma.
Chen D; Hu YN; Hussain D; Zhu GT; Huang YQ; Feng YQ
Talanta; 2016 May; 152():188-95. PubMed ID: 26992510
[TBL] [Abstract][Full Text] [Related]
7. Rapid determination of immunosuppressive drug concentrations in whole blood by coated blade spray-tandem mass spectrometry (CBS-MS/MS).
Gómez-Ríos GA; Tascon M; Reyes-Garcés N; Boyacı E; Poole JJ; Pawliszyn J
Anal Chim Acta; 2018 Jan; 999():69-75. PubMed ID: 29254576
[TBL] [Abstract][Full Text] [Related]
8. Coated Blade Spray with a Barrier: Improving Negative Electrospray Ionization and Sample Preparation.
Zhou W; Pawliszyn J
Anal Chem; 2022 Nov; 94(45):15879-15886. PubMed ID: 36326684
[TBL] [Abstract][Full Text] [Related]
9. Rapid screening of drugs in environmental water using metal organic framework/Ti
Hu K; Zhou W; Yang C; Wang Y; Jiang RW; Zhang Z; Pawliszyn J
J Hazard Mater; 2024 Jul; 472():134609. PubMed ID: 38759280
[TBL] [Abstract][Full Text] [Related]
10. Coated Blade Spray-Mass Spectrometry as a New Approach for the Rapid Characterization of Brain Tumors.
Bogusiewicz J; Gaca-Tabaszewska M; Olszówka D; Jaroch K; Furtak J; Harat M; Pawliszyn J; Bojko B
Molecules; 2022 Mar; 27(7):. PubMed ID: 35408649
[TBL] [Abstract][Full Text] [Related]
11. Multi-class pesticide analysis in cannabis oil using coated blade spray and solid-phase microextraction with liquid chromatography coupled to mass spectrometry.
Kasperkiewicz A; Pawliszyn J
Talanta; 2021 Apr; 225():122036. PubMed ID: 33592761
[TBL] [Abstract][Full Text] [Related]
12. Optimization of the coating procedure for a high-throughput 96-blade solid phase microextraction system coupled with LC-MS/MS for analysis of complex samples.
Mirnaghi FS; Chen Y; Sidisky LM; Pawliszyn J
Anal Chem; 2011 Aug; 83(15):6018-25. PubMed ID: 21711040
[TBL] [Abstract][Full Text] [Related]
13. Comparison of different approaches for direct coupling of solid-phase microextraction to mass spectrometry for drugs of abuse analysis in plasma.
Zhou W; Wieczorek MN; Jiang RW; Pawliszyn J
J Pharm Anal; 2023 Feb; 13(2):216-222. PubMed ID: 36908852
[TBL] [Abstract][Full Text] [Related]
14. Time-course monitoring of
Jaroch K; Pawliszyn J
J Pharm Anal; 2022 Feb; 12(1):186-191. PubMed ID: 35573877
[TBL] [Abstract][Full Text] [Related]
15. Rapid and Concomitant Analysis of Pharmaceuticals in Treated Wastewater by Coated Blade Spray Mass Spectrometry.
Poole JJ; Gómez-Ríos GA; Boyaci E; Reyes-Garcés N; Pawliszyn J
Environ Sci Technol; 2017 Nov; 51(21):12566-12572. PubMed ID: 28990769
[TBL] [Abstract][Full Text] [Related]
16. Development of a thin-film solid-phase microextraction (TF-SPME) method coupled to liquid chromatography and tandem mass spectrometry for high-throughput determination of steroid hormones in white sucker fish plasma.
Maciążek-Jurczyk M; Bessonneau V; Ings J; Bragg L; McMaster M; Servos MR; Bojko B; Pawliszyn J
Anal Bioanal Chem; 2020 Jul; 412(17):4183-4194. PubMed ID: 32361868
[TBL] [Abstract][Full Text] [Related]
17. Aptamer-functionalized solid phase microextraction-liquid chromatography/tandem mass spectrometry for selective enrichment and determination of thrombin.
Du F; Alam MN; Pawliszyn J
Anal Chim Acta; 2014 Oct; 845():45-52. PubMed ID: 25201271
[TBL] [Abstract][Full Text] [Related]
18. Development of a Biocompatible Solid Phase Microextraction Thin Film Coating for the Sampling and Enrichment of Peptides.
Onat B; Rosales-Solano H; Pawliszyn J
Anal Chem; 2020 Jul; 92(13):9379-9388. PubMed ID: 32500703
[TBL] [Abstract][Full Text] [Related]
19. Analysis of food samples made easy by microextraction technologies directly coupled to mass spectrometry.
Gionfriddo E; Gómez-Ríos GA
J Mass Spectrom; 2021 Jan; 56(1):e4665. PubMed ID: 33098354
[TBL] [Abstract][Full Text] [Related]
20. Polyacrylonitrile / graphene oxide nanofibers for packed sorbent microextraction of drugs and their metabolites from human plasma samples.
Karimiyan H; Uheida A; Hadjmohammadi M; Moein MM; Abdel-Rehim M
Talanta; 2019 Aug; 201():474-479. PubMed ID: 31122453
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]