These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
123 related articles for article (PubMed ID: 38843532)
1. Technical note: Characterization of a multi-point scintillation dosimetry research platform for a low-field MR-Linac. Crosby J; Ruff C; Gregg K; Turcotte J; Glide-Hurst C Med Phys; 2024 Sep; 51(9):6475-6484. PubMed ID: 38843532 [TBL] [Abstract][Full Text] [Related]
2. Performance of the HYPERSCINT scintillation dosimetry research platform for the 1.5 T MR-linac. Uijtewaal P; Côté B; Foppen T; de Vries W; Woodings S; Borman P; Lambert-Girard S; Therriault-Proulx F; Raaymakers B; Fast M Phys Med Biol; 2023 Feb; 68(4):. PubMed ID: 36638536 [No Abstract] [Full Text] [Related]
3. Development and first implementation of a novel multi-modality cardiac motion and dosimetry phantom for radiotherapy applications. Gregg KW; Ruff C; Koenig G; Penev KI; Shepard A; Kreissler G; Amatuzio M; Owens C; Nagpal P; Glide-Hurst CK Med Phys; 2024 Oct; 51(10):7479-7491. PubMed ID: 39042362 [TBL] [Abstract][Full Text] [Related]
4. Performance characterization of a novel hybrid dosimetry insert for simultaneous spatial, temporal, and motion-included dosimetry for MR-linac. Uijtewaal P; Borman P; Cote B; LeChasseur Y; Therriault-Proulx F; Flores R; Smith S; Koenig G; Raaymakers B; Fast M Med Phys; 2024 Apr; 51(4):2983-2997. PubMed ID: 38088939 [TBL] [Abstract][Full Text] [Related]
6. Dosimetric characterization of a novel commercial plastic scintillation detector with an MR-Linac. Ferrer C; Huertas C; García D; Sáez M Med Phys; 2023 Apr; 50(4):2525-2539. PubMed ID: 36611266 [TBL] [Abstract][Full Text] [Related]
7. Computational and experimental small field dosimetry using a commercial plastic scintillator detector for the 0.35 T MR-linac. Khan AU; Das IJ; Yadav P Phys Med; 2024 Jul; 123():103403. PubMed ID: 38870643 [TBL] [Abstract][Full Text] [Related]
8. Influence of magnetic field on a novel scintillation dosimeter in a 1.5 T MR-linac. Oolbekkink S; van Asselen B; Woodings SJ; Wolthaus JWH; de Vries JHW; van Appeldoorn AA; Feijoo M; van den Dobbelsteen M; Raaymakers BW J Appl Clin Med Phys; 2024 Jan; 25(1):e14180. PubMed ID: 38011008 [TBL] [Abstract][Full Text] [Related]
9. Characterization of the plastic scintillation detector Exradin W2 for small field dosimetry. Galavis PE; Hu L; Holmes S; Das IJ Med Phys; 2019 May; 46(5):2468-2476. PubMed ID: 30897221 [TBL] [Abstract][Full Text] [Related]
10. Characterization of an inorganic scintillator for small-field dosimetry in MR-guided radiotherapy. Cusumano D; Placidi L; D'Agostino E; Boldrini L; Menna S; Valentini V; De Spirito M; Azario L J Appl Clin Med Phys; 2020 Sep; 21(9):244-251. PubMed ID: 32841500 [TBL] [Abstract][Full Text] [Related]
11. Characterization of a 0.8 mm Timakova E; Bazalova-Carter M; Zavgorodni S Phys Med Biol; 2023 Aug; 68(17):. PubMed ID: 37494941 [No Abstract] [Full Text] [Related]
12. First measurements with a plastic scintillation dosimeter at the Australian MRI-LINAC. Madden L; Archer J; Li E; Jelen U; Dong B; Roberts N; Holloway L; Rosenfeld A Phys Med Biol; 2019 Sep; 64(17):175015. PubMed ID: 31307025 [TBL] [Abstract][Full Text] [Related]
13. Relative dosimetry with an MR-linac: Response of ion chambers, diamond, and diode detectors for off-axis, depth dose, and output factor measurements. O'Brien DJ; Dolan J; Pencea S; Schupp N; Sawakuchi GO Med Phys; 2018 Feb; 45(2):884-897. PubMed ID: 29178457 [TBL] [Abstract][Full Text] [Related]
14. Consequences of air around an ionization chamber: Are existing solid phantoms suitable for reference dosimetry on an MR-linac? Hackett SL; van Asselen B; Wolthaus JW; Kok JG; Woodings SJ; Lagendijk JJ; Raaymakers BW Med Phys; 2016 Jul; 43(7):3961. PubMed ID: 27370114 [TBL] [Abstract][Full Text] [Related]
15. Technical Note: Time-gating to medical linear accelerator pulses: Stray radiation detector. Ashraf MR; Bruza P; Krishnaswamy V; Gladstone DJ; Pogue BW Med Phys; 2019 Feb; 46(2):1044-1048. PubMed ID: 30488442 [TBL] [Abstract][Full Text] [Related]
17. MRI-LINAC beam profile measurements using a plastic scintillation dosimeter. Madden L; Archer J; Li E; Jelen U; Dong B; Holloway L; Rosenfeld A Phys Med; 2020 May; 73():111-116. PubMed ID: 32361155 [TBL] [Abstract][Full Text] [Related]
18. Quantifying uncertainties associated with reference dosimetry in an MR-Linac. Iakovenko V; Keller B; Malkov VN; Sahgal A; Sarfehnia A J Appl Clin Med Phys; 2023 Nov; 24(11):e14087. PubMed ID: 37354202 [TBL] [Abstract][Full Text] [Related]
19. Small field measurements using electronic portal imaging device. Sait AA; Yoganathan SA; Jones GW; Patel T; Rastogi N; Pandey SP; Mani S; Boopathy R Biomed Phys Eng Express; 2024 Jul; 10(5):. PubMed ID: 38906125 [No Abstract] [Full Text] [Related]
20. Scintillation imaging as a high-resolution, remote, versatile 2D detection system for MR-linac quality assurance. Alexander DA; Zhang R; Brůža P; Pogue BW; Gladstone DJ Med Phys; 2020 Sep; 47(9):3861-3869. PubMed ID: 32583484 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]