These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 38849456)

  • 1. Design and implementation of a high misalignment-tolerance wireless charger for an electric vehicle with control of the constant current/voltage charging.
    Ramakrishnan V; A DS; C B; R N; Vishnuram P; Yang T; Bajaj M; Rathore RS; Zaitsev I
    Sci Rep; 2024 Jun; 14(1):13165. PubMed ID: 38849456
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Foreign object detection considering misalignment effect for wireless EV charging system.
    Niu S; Zhang C; Shi Y; Niu S; Jian L
    ISA Trans; 2022 Nov; 130():655-666. PubMed ID: 35525608
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Enhancing electric vehicle charging performance through series-series topology resonance-coupled wireless power transfer.
    Benalia N; Benlaloui I; Laroussi K; Elkhateb A; Mbadjoun Wapet DE; Hassan AM; Mahmoud MM
    PLoS One; 2024; 19(3):e0300550. PubMed ID: 38512925
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ultrawideband (UWB)-based precise short-range localization for wireless power transfer to electric vehicles in parking environments.
    Lee SM
    PeerJ Comput Sci; 2021; 7():e567. PubMed ID: 34141892
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Alignment-Free Wireless Charging of Smart Garments with Embroidered Coils.
    Chang CW; Riehl P; Lin J
    Sensors (Basel); 2021 Nov; 21(21):. PubMed ID: 34770679
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Thin, stretchable, universal wireless power transfer system for electric vehicle charging.
    Guo Y; Zhang H; Liu H; Li S; Yin S; Cao P; Zhang L; Ping X; Guo L
    RSC Adv; 2020 Sep; 10(58):35426-35432. PubMed ID: 35515655
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Wireless power transfer analysis of circular and spherical coils under misalignment conditions for biomedical implants.
    Palagani Y; Mohanarangam K; Shim JH; Choi JR
    Biosens Bioelectron; 2019 Sep; 141():111283. PubMed ID: 31295707
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multifunctional coil technique for alignment-agnostic and Rx coil size-insensitive efficiency enhancement for wireless power transfer applications.
    Yoon S; Lim T; Lee Y
    Sci Rep; 2023 Dec; 13(1):22838. PubMed ID: 38129641
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Misalignment tolerable coil structure for biomedical applications with wireless power transfer.
    Chow JP; Chen N; Chung HS; Chan LL
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():775-8. PubMed ID: 24109802
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Enhancing the Stability of Medium Range and Misalignment Wireless Power Transfer System by Negative Magnetic Metamaterials.
    Wang S; Jiang C; Tao X; Chen F; Rong C; Lu C; Zeng Y; Liu X; Liu R; Wei B; Liu M
    Materials (Basel); 2020 Dec; 13(24):. PubMed ID: 33327379
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Coupling coefficient calculation and optimization of positive rectangular series coils in wireless power transfer systems.
    Leng Y; Luo D; Li Z; Yu F
    Heliyon; 2023 Oct; 9(10):e21121. PubMed ID: 37916117
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Coil Positioning for Wireless Power Transfer System of Automatic Guided Vehicle Based on Magnetic Sensing.
    Liang C; Zhang Y; Li Z; Yuan F; Yang G; Song K
    Sensors (Basel); 2020 Sep; 20(18):. PubMed ID: 32947993
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Measurement Method of Power Transferred to an Electric Vehicle Using Wireless Charging.
    Nakutis Ž; Lukočius R; Girdenis V; Kroičs K
    Sensors (Basel); 2023 Dec; 23(24):. PubMed ID: 38139482
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analysis and experimental verification of efficiency parameters affecting inductively coupled wireless power transfer systems.
    Özüpak Y
    Heliyon; 2024 Mar; 10(5):e27420. PubMed ID: 38495211
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Impact of Coil Position and Number on Wireless System Performance for Electric Vehicle Recharging.
    Mohamed N; Aymen F; Issam Z; Bajaj M; Ghoneim SSM; Ahmed M
    Sensors (Basel); 2021 Jun; 21(13):. PubMed ID: 34201995
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Study on the Optimal Magnetic Beam Forming of Coil Arrays for Long Distance Wireless Power Transmission.
    Oh MJ; Danuor P; Jung YB
    Sensors (Basel); 2023 Jun; 23(11):. PubMed ID: 37300041
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intelligent control of integrated on-board charger with improved power quality and reduced charging transients.
    Ghosh S; Singh AK; Singh R; Maurya R; Singh SN; Yang G
    ISA Trans; 2023 Apr; 135():355-368. PubMed ID: 37032567
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Robust voltage-controlled transcutaneous energy transfer system for artificial anal sphincter.
    Chen Y; Jiang P; Wang L; Yan G; Wang Z; Liu C; Han D
    Artif Organs; 2024 Jan; 48(1):37-49. PubMed ID: 37846614
    [TBL] [Abstract][Full Text] [Related]  

  • 19. On-Line Foreign Object Detection Using Double DD Coils in an Inductive Wireless Power Transfer System.
    Prosen N; Milanovič M; Domajnko J
    Sensors (Basel); 2022 Feb; 22(4):. PubMed ID: 35214539
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improvement of wireless power transmission efficiency of implantable subcutaneous devices by closed magnetic circuit mechanism.
    Jo SE; Joung S; Suh JK; Kim YJ
    Med Biol Eng Comput; 2012 Sep; 50(9):973-80. PubMed ID: 22806430
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.