These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 38864982)

  • 41. Heart rate and early progression of cardiac allograft vasculopathy: A prospective study using highly automated 3-D optical coherence tomography analysis.
    Pazdernik M; Wichterle D; Chen Z; Bedanova H; Kautzner J; Melenovsky V; Karmazin V; Malek I; Stiavnicky P; Tomasek A; Ozabalova E; Krejci J; Wahle A; Zhang H; Kovarnik T; Sonka M
    Clin Transplant; 2020 Feb; 34(2):e13773. PubMed ID: 31859379
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Timing of 3-hydroxy-3-methylglutaryl-coenzyme A reductase inhibitor initiation and allograft vasculopathy progression and outcomes in heart transplant recipients.
    Asleh R; Briasoulis A; Pereira NL; Boilson BA; Edwards BS; Adigun R; Maltais S; Daly RC; Lerman A; Kushwaha SS
    ESC Heart Fail; 2018 Dec; 5(6):1118-1129. PubMed ID: 30019530
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Donor-Transmitted Atherosclerosis Associated With Worsening Cardiac Allograft Vasculopathy After Heart Transplantation: Serial Volumetric Intravascular Ultrasound Analysis.
    Watanabe T; Seguchi O; Yanase M; Fujita T; Murata Y; Sato T; Sunami H; Nakajima S; Kataoka Y; Nishimura K; Hisamatsu E; Kuroda K; Okada N; Hori Y; Wada K; Hata H; Ishibashi-Ueda H; Miyamoto Y; Fukushima N; Kobayashi J; Nakatani T
    Transplantation; 2017 Jun; 101(6):1310-1319. PubMed ID: 27472091
    [TBL] [Abstract][Full Text] [Related]  

  • 44. In Vivo Calcium Detection by Comparing Optical Coherence Tomography, Intravascular Ultrasound, and Angiography.
    Wang X; Matsumura M; Mintz GS; Lee T; Zhang W; Cao Y; Fujino A; Lin Y; Usui E; Kanaji Y; Murai T; Yonetsu T; Kakuta T; Maehara A
    JACC Cardiovasc Imaging; 2017 Aug; 10(8):869-879. PubMed ID: 28797408
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Invasive aortic pulse pressure is linked to cardiac allograft vasculopathy after heart transplantation.
    Park HW; Ozcan I; Toya T; Ahmad A; Kanaji Y; Kushwaha SS; Lerman LO; Lerman A
    Int J Cardiol; 2023 Jan; 370():167-174. PubMed ID: 36346255
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Comparison of sixty-four-slice multidetector computed tomographic coronary angiography to coronary angiography with intravascular ultrasound for the detection of transplant vasculopathy.
    Gregory SA; Ferencik M; Achenbach S; Yeh RW; Hoffmann U; Inglessis I; Cury RC; Nieman K; McNulty IA; Laffan JA; Pomerantsev EV; Brady TJ; Semigran MJ; Jang IK
    Am J Cardiol; 2006 Oct; 98(7):877-84. PubMed ID: 16996866
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Progression of cardiac allograft vasculopathy detected by optical coherence tomography.
    Yamada R; Yoshida K; Okura H
    Coron Artery Dis; 2015 Aug; 26(5):459-60. PubMed ID: 25714071
    [No Abstract]   [Full Text] [Related]  

  • 48. Quantification of myocardial interstitial fibrosis and extracellular volume for the detection of cardiac allograft vasculopathy.
    van Heeswijk RB; Bastiaansen JAM; Iglesias JF; Degrauwe S; Rotman S; Barras JL; Regamey J; Lauriers N; Tozzi P; Yerly J; Ginami G; Stuber M; Hullin R
    Int J Cardiovasc Imaging; 2020 Mar; 36(3):533-542. PubMed ID: 31724114
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Enhancing the Prediction of Cardiac Allograft Vasculopathy Using Intravascular Ultrasound and Machine Learning: A Proof of Concept.
    Moayedi Y; Rodenas-Alesina E; Somerset E; Fan CPS; Henricksen E; Aleksova N; Billia F; Chih S; Ross HJ; Teuteberg JJ
    Circ Heart Fail; 2024 Feb; 17(2):e011306. PubMed ID: 38314558
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Monitoring of allograft vasculopathy by intravascular ultrasound one month and one year after heart transplantation: A single center study.
    Bedanova H; Orban M; Tretina M; Fila P; Horvath V; Krejci J; Nemec P
    Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub; 2016 Mar; 160(1):130-5. PubMed ID: 26220510
    [TBL] [Abstract][Full Text] [Related]  

  • 51. PET assessment of myocardial perfusion reserve inversely correlates with intravascular ultrasound findings in angiographically normal cardiac transplant recipients.
    Wu YW; Chen YH; Wang SS; Jui HY; Yen RF; Tzen KY; Chen MF; Lee CM
    J Nucl Med; 2010 Jun; 51(6):906-12. PubMed ID: 20484427
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Risk factors for early development of cardiac allograft vasculopathy by intravascular ultrasound.
    Moayedi Y; Fan CPS; Tremblay-Gravel M; Miller RJH; Kawana M; Henricksen E; Parizo J; Wainwright R; Fearon WF; Ross HJ; Khush KK; Teuteberg JJ
    Clin Transplant; 2020 Nov; 34(11):e14098. PubMed ID: 32970884
    [TBL] [Abstract][Full Text] [Related]  

  • 53. PET Assessment of Epicardial Intimal Disease and Microvascular Dysfunction in Cardiac Allograft Vasculopathy.
    Chih S; Chong AY; Erthal F; deKemp RA; Davies RA; Stadnick E; So DY; Overgaard C; Wells G; Mielniczuk LM; Beanlands RSB
    J Am Coll Cardiol; 2018 Apr; 71(13):1444-1456. PubMed ID: 29598865
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Angiogenesis on coronary angiography is a marker for accelerated cardiac allograft vasculopathy as assessed by intravascular ultrasound.
    Cheng R; Kransdorf EP; Wei J; Patel JK; Kobashigawa JA; Azarbal B
    Clin Transplant; 2017 Nov; 31(11):. PubMed ID: 28786501
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Serial 3-Vessel Optical Coherence Tomography and Intravascular Ultrasound Analysis of Changing Morphologies Associated With Lesion Progression in Patients With Stable Angina Pectoris.
    Yamamoto MH; Yamashita K; Matsumura M; Fujino A; Ishida M; Ebara S; Okabe T; Saito S; Hoshimoto K; Amemiya K; Yakushiji T; Isomura N; Araki H; Obara C; McAndrew T; Ochiai M; Mintz GS; Maehara A
    Circ Cardiovasc Imaging; 2017 Sep; 10(9):. PubMed ID: 28893795
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Assessment and characterization of time-related differences in plaque composition by intravascular ultrasound-derived radiofrequency analysis in heart transplant recipients.
    König A; Kilian E; Sohn HY; Rieber J; Schiele TM; Siebert U; Gothe RM; Reichart B; Klauss V
    J Heart Lung Transplant; 2008 Mar; 27(3):302-9. PubMed ID: 18342753
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Effect of Everolimus Initiation and Calcineurin Inhibitor Elimination on Cardiac Allograft Vasculopathy in De Novo Heart Transplant Recipients.
    Arora S; Andreassen AK; Karason K; Gustafsson F; Eiskjær H; Bøtker HE; Rådegran G; Gude E; Ioanes D; Solbu D; Dellgren G; Ueland T; Aukrust P; Gullestad L;
    Circ Heart Fail; 2018 Sep; 11(9):e004050. PubMed ID: 30354362
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Prevalence of cardiac allograft vasculopathy assessed with coronary angiography versus coronary vascular ultrasound and virtual histology.
    Torres HJ; Merello L; Ramos SA; Aninat MA; Becerra LE; Mora AD; Valenzuela PT; Godoy MJ; Prieto AA
    Transplant Proc; 2011; 43(6):2318-21. PubMed ID: 21839263
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology.
    Shimokado A; Kubo T; Matsuo Y; Ino Y; Shiono Y; Shimamura K; Katayama Y; Taruya A; Nishiguchi T; Kashiwagi M; Kitabata H; Tanaka A; Hozumi T; Akasaka T
    Int J Cardiovasc Imaging; 2019 Oct; 35(10):1785-1790. PubMed ID: 31175528
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Follow-up study on the utility of von Willebrand factor levels in the diagnosis of cardiac allograft vasculopathy.
    Martínez-Dolz L; Almenar L; Reganon E; Vila V; Chamorro C; Andrés L; Martínez-Sales V; Moro J; Agüero J; Sánchez-Lázaro I; Salvador A
    J Heart Lung Transplant; 2008 Jul; 27(7):760-6. PubMed ID: 18582806
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.