These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
120 related articles for article (PubMed ID: 38908235)
1. Salt assisted liquid-liquid extraction combined with dispersive liquid-liquid microextraction for the determination of 24 regulated polycyclic aromatic hydrocarbons in human serum. Boughanem C; Delaunay N; Pichon V J Pharm Biomed Anal; 2024 Sep; 248():116319. PubMed ID: 38908235 [TBL] [Abstract][Full Text] [Related]
2. [Simultaneous determination of polycyclic aromatic hydrocarbons and phthalate esters in surface water by dispersive liquid-liquid microextraction based on solidification of floating organic drop followed by high performance liquid chromatography]. Yuan J; Wang J; Xu W; Xu F; Lu X Se Pu; 2020 Nov; 38(11):1308-1315. PubMed ID: 34213102 [TBL] [Abstract][Full Text] [Related]
3. Extraction optimization of polycyclic aromatic hydrocarbons by alcoholic-assisted dispersive liquid-liquid microextraction and their determination by HPLC. Fatemi MH; Hadjmohammadi MR; Shakeri P; Biparva P J Sep Sci; 2012 Jan; 35(1):86-92. PubMed ID: 22125263 [TBL] [Abstract][Full Text] [Related]
4. Green aspects, developments and perspectives of liquid phase microextraction techniques. Spietelun A; Marcinkowski Ł; de la Guardia M; Namieśnik J Talanta; 2014 Feb; 119():34-45. PubMed ID: 24401382 [TBL] [Abstract][Full Text] [Related]
5. Countercurrent Salting-out Homogenous Liquid-Liquid Extraction and Dispersive Liquid-Liquid Microextraction Based on the Solidification of Floating Organic Drop Followed by High-Performance Liquid Chromatography for the Isolation and Preconcentration of Pesticides from Fruit Samples. Teymori Z; Sadeghi M; Fattahi N J AOAC Int; 2022 Apr; 105(3):802-811. PubMed ID: 34904642 [TBL] [Abstract][Full Text] [Related]
6. Determination of polycyclic aromatic hydrocarbons using lab on valve dispersive liquid-liquid microextraction coupled to high performance chromatography. Fernández M; Clavijo S; Forteza R; Cerdà V Talanta; 2015 Jun; 138():190-195. PubMed ID: 25863390 [TBL] [Abstract][Full Text] [Related]
7. Optimization of two different dispersive liquid-liquid microextraction methods followed by gas chromatography-mass spectrometry determination for polycyclic aromatic hydrocarbons (PAHs) analysis in water. Tseng WC; Chen PS; Huang SD Talanta; 2014 Mar; 120():425-32. PubMed ID: 24468392 [TBL] [Abstract][Full Text] [Related]
8. Simultaneous Dispersive Liquid-Liquid Microextraction and Determination of Different Polycyclic Aromatic Hydrocarbons in Surface Water. Temerdashev Z; Prasad S; Musorina T; Chervonnaya T; Arutyunyan Z Molecules; 2022 Dec; 27(23):. PubMed ID: 36500677 [TBL] [Abstract][Full Text] [Related]
9. [Low-density solvent-based solvent demulsification dispersive liquid-liquid microextraction combined with gas chromatography for determination of polycyclic aromatic hydrocarbons in water samples]. Zhu B; Chen H; Li S Se Pu; 2012 Feb; 30(2):201-6. PubMed ID: 22679837 [TBL] [Abstract][Full Text] [Related]
10. Vortex-assisted extraction combined with dispersive liquid-liquid microextraction for the determination of polycyclic aromatic hydrocarbons in sediment by high performance liquid chromatography. Leng G; Lui G; Chen Y; Yin H; Dan D J Sep Sci; 2012 Oct; 35(20):2796-804. PubMed ID: 22893532 [TBL] [Abstract][Full Text] [Related]
11. Capabilities and limitations of dispersive liquid-liquid microextraction with solidification of floating organic drop for the extraction of organic pollutants from water samples. Vera-Avila LE; Rojo-Portillo T; Covarrubias-Herrera R; Peña-Alvarez A Anal Chim Acta; 2013 Dec; 805():60-9. PubMed ID: 24296144 [TBL] [Abstract][Full Text] [Related]
12. Fast automated dual-syringe based dispersive liquid-liquid microextraction coupled with gas chromatography-mass spectrometry for the determination of polycyclic aromatic hydrocarbons in environmental water samples. Guo L; Tan S; Li X; Lee HK J Chromatogr A; 2016 Mar; 1438():1-9. PubMed ID: 26893021 [TBL] [Abstract][Full Text] [Related]
13. Rapid extraction and determination of amphetamines in human urine samples using dispersive liquid-liquid microextraction and solidification of floating organic drop followed by high performance liquid chromatography. Ahmadi-Jouibari T; Fattahi N; Shamsipur M J Pharm Biomed Anal; 2014 Jun; 94():145-51. PubMed ID: 24583909 [TBL] [Abstract][Full Text] [Related]
14. Analysis of persistent contaminants and personal care products by dispersive liquid-liquid microextraction using hydrophobic magnetic deep eutectic solvents. Farooq MQ; Ocaña-Rios I; Anderson JL J Chromatogr A; 2022 Oct; 1681():463429. PubMed ID: 36057209 [TBL] [Abstract][Full Text] [Related]
15. Rapid determination of polycyclic aromatic hydrocarbons in grilled meat using microwave-assisted extraction and dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry. Kamankesh M; Mohammadi A; Hosseini H; Modarres Tehrani Z Meat Sci; 2015 May; 103():61-7. PubMed ID: 25618021 [TBL] [Abstract][Full Text] [Related]
16. A combined microextraction procedure for isolation of polycyclic aromatic hydrocarbons in ambient fine air particulate matter with determination by gas chromatography-tandem mass spectrometry. Naing NN; Yeo KB; Lee HK J Chromatogr A; 2020 Feb; 1612():460646. PubMed ID: 31672268 [TBL] [Abstract][Full Text] [Related]
17. A novel dispersive liquid-liquid microextraction using a low density deep eutectic solvent-gas chromatography tandem mass spectrometry for the determination of polycyclic aromatic hydrocarbons in soft drinks. Caldeirão L; Fernandes JO; Gonzalez MH; Godoy HT; Cunha SC J Chromatogr A; 2021 Jan; 1635():461736. PubMed ID: 33254001 [TBL] [Abstract][Full Text] [Related]
18. Air-assisted liquid-liquid microextraction based on the solidification of floating deep eutectic solvents for the simultaneous determination of bisphenols and polycyclic aromatic hydrocarbons in tea infusions via HPLC. Zhang K; Wang Y; Li S; Zhu G Food Chem; 2021 Jun; 348():129106. PubMed ID: 33516999 [TBL] [Abstract][Full Text] [Related]
19. On-line combining monolith-based in-tube solid phase microextraction and high-performance liquid chromatography- fluorescence detection for the sensitive monitoring of polycyclic aromatic hydrocarbons in complex samples. Pang J; Yuan D; Huang X J Chromatogr A; 2018 Oct; 1571():29-37. PubMed ID: 30177269 [TBL] [Abstract][Full Text] [Related]
20. Application of magnetic dispersive solid phase extraction combined with solidification of floating organic droplet-based dispersive liquid-liquid microextraction and GC-MS in the extraction and determination of polycyclic aromatic hydrocarbons in honey. Mohebbi A; Fathi AA; Afshar Mogaddam MR; Farajzadeh MA; Yaripour S; Fattahi N Food Addit Contam Part A Chem Anal Control Expo Risk Assess; 2024 Feb; 41(2):175-187. PubMed ID: 38252747 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]