138 related articles for article (PubMed ID: 3890974)
1. Interface analysis of titanium and zirconium bone implants.
Albrektsson T; Hansson HA; Ivarsson B
Biomaterials; 1985 Mar; 6(2):97-101. PubMed ID: 3890974
[TBL] [Abstract][Full Text] [Related]
2. An ultrastructural characterization of the interface between bone and sputtered titanium or stainless steel surfaces.
Albrektsson T; Hansson HA
Biomaterials; 1986 May; 7(3):201-5. PubMed ID: 3521751
[TBL] [Abstract][Full Text] [Related]
3. Electron microscopic analysis of the bone-titanium interface.
Linder L; Albrektsson T; Brånemark PI; Hansson HA; Ivarsson B; Jönsson U; Lundström I
Acta Orthop Scand; 1983 Feb; 54(1):45-52. PubMed ID: 6829281
[TBL] [Abstract][Full Text] [Related]
4. Interface between titanium 6,4 alloy implants and bone.
Katsikeris N; Listrom RD; Symington JM
Int J Oral Maxillofac Surg; 1987 Aug; 16(4):473-6. PubMed ID: 3117922
[TBL] [Abstract][Full Text] [Related]
5. Light and transmission electron microscopy used to study the tissue morphology close to implants.
Thomsen P; Ericson LE
Biomaterials; 1985 Nov; 6(6):421-4. PubMed ID: 4084645
[TBL] [Abstract][Full Text] [Related]
6. Visualization and initial characterization of the titanium boundary of the bone-implant interface of osseointegrated implants.
Budd TW; Nagahara K; Bielat KL; Meenaghan MA; Schaaf NG
Int J Oral Maxillofac Implants; 1992; 7(2):151-60. PubMed ID: 1398831
[TBL] [Abstract][Full Text] [Related]
7. Qualitative interfacial study between bone and tantalum, niobium or commercially pure titanium.
Johansson CB; Hansson HA; Albrektsson T
Biomaterials; 1990 May; 11(4):277-80. PubMed ID: 2383624
[TBL] [Abstract][Full Text] [Related]
8. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man.
Albrektsson T; Brånemark PI; Hansson HA; Lindström J
Acta Orthop Scand; 1981; 52(2):155-70. PubMed ID: 7246093
[TBL] [Abstract][Full Text] [Related]
9. Ultrastructure of the interface between titanium and surrounding tissue in rat tibiae--a comparison study on titanium-coated and -uncoated plastic implants.
Okamatsu K; Kido H; Sato A; Watazu A; Matsuura M
Clin Implant Dent Relat Res; 2007 Jun; 9(2):100-11. PubMed ID: 17535334
[TBL] [Abstract][Full Text] [Related]
10. Bone-bonding behavior of plasma-sprayed coatings of BioglassR, AW-glass ceramic, and tricalcium phosphate on titanium alloy.
Kitsugi T; Nakamura T; Oka M; Senaha Y; Goto T; Shibuya T
J Biomed Mater Res; 1996 Feb; 30(2):261-9. PubMed ID: 9019492
[TBL] [Abstract][Full Text] [Related]
11. A comparative study of zirconium and titanium implants in rat: osseointegration and bone material quality.
Hoerth RM; Katunar MR; Gomez Sanchez A; Orellano JC; Ceré SM; Wagermaier W; Ballarre J
J Mater Sci Mater Med; 2014 Feb; 25(2):411-22. PubMed ID: 24170339
[TBL] [Abstract][Full Text] [Related]
12. Method for ultrastructural studies of the intact tissue-metal interface.
Bjursten LM; Emanuelsson L; Ericson LE; Thomsen P; Lausmaa J; Mattsson L; Rolander U; Kasemo B
Biomaterials; 1990 Oct; 11(8):596-601. PubMed ID: 2279062
[TBL] [Abstract][Full Text] [Related]
13. Osteoblasts generate harder, stiffer, and more delamination-resistant mineralized tissue on titanium than on polystyrene, associated with distinct tissue micro- and ultrastructure.
Saruwatari L; Aita H; Butz F; Nakamura HK; Ouyang J; Yang Y; Chiou WA; Ogawa T
J Bone Miner Res; 2005 Nov; 20(11):2002-16. PubMed ID: 16234974
[TBL] [Abstract][Full Text] [Related]
14. Apatite layer-coated titanium for use as bone bonding implants.
Yan WQ; Nakamura T; Kawanabe K; Nishigochi S; Oka M; Kokubo T
Biomaterials; 1997 Sep; 18(17):1185-90. PubMed ID: 9259516
[TBL] [Abstract][Full Text] [Related]
15. Enhanced biocompatibility and osseointegration of calcium titanate coating on titanium screws in rabbit femur.
Wang ZL; He RZ; Tu B; Cao X; He JS; Xia HS; Liang C; Zou M; Wu S; Wu ZJ; Xiong K
J Huazhong Univ Sci Technolog Med Sci; 2017 Jun; 37(3):362-370. PubMed ID: 28585129
[TBL] [Abstract][Full Text] [Related]
16. A light and electron microscopic study of the effects of surface topography on the behavior of cells attached to titanium-coated percutaneous implants.
Chehroudi B; Gould TR; Brunette DM
J Biomed Mater Res; 1991 Mar; 25(3):387-405. PubMed ID: 2026643
[TBL] [Abstract][Full Text] [Related]
17. [Experimental study of osseointegration of zirconium and titanium dental implants].
Kulakov OB; Doktorov AA; D'iakova SV; Denisov-Nikol'skiĭ IuI; Grötz KA
Morfologiia; 2005; 127(1):52-5. PubMed ID: 16080351
[TBL] [Abstract][Full Text] [Related]
18. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs.
Buser D; Schenk RK; Steinemann S; Fiorellini JP; Fox CH; Stich H
J Biomed Mater Res; 1991 Jul; 25(7):889-902. PubMed ID: 1918105
[TBL] [Abstract][Full Text] [Related]
19. A histomorphometric study of tissue interface by laminar implant test in rats.
Guglielmotti MB; Renou S; Cabrini RL
Int J Oral Maxillofac Implants; 1999; 14(4):565-70. PubMed ID: 10453673
[TBL] [Abstract][Full Text] [Related]
20. Osteogenesis and morphology of the peri-implant bone facing dental implants.
Franchi M; Orsini E; Trire A; Quaranta M; Martini D; Piccari GG; Ruggeri A; Ottani V
ScientificWorldJournal; 2004 Dec; 4():1083-95. PubMed ID: 15632988
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]