BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 38929429)

  • 21. Evaluation of 2D Imaging Schemes for Pulsed Arterial Spin Labeling of the Human Kidney Cortex.
    Buchanan CE; Cox EF; Francis ST
    Diagnostics (Basel); 2018 Jun; 8(3):. PubMed ID: 29958409
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Inter-study reproducibility of arterial spin labelling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla.
    Gillis KA; McComb C; Foster JE; Taylor AH; Patel RK; Morris ST; Jardine AG; Schneider MP; Roditi GH; Delles C; Mark PB
    BMC Nephrol; 2014 Jan; 15():23. PubMed ID: 24484613
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Arterial Spin Labeling MRI for Predicting Microvascular Invasion of T1 Staging Renal Clear Cell Carcinoma Preoperatively.
    Zhang HM; Wen DG; Wang Y; Bao YG; Yuan Y; Chen YT; Song B
    Front Oncol; 2021; 11():644975. PubMed ID: 34084743
    [TBL] [Abstract][Full Text] [Related]  

  • 24. MRI-based quantification of renal perfusion in mice: Improving sensitivity and stability in FAIR ASL.
    Gutjahr FT; Günster SM; Kampf T; Winter P; Herold V; Bauer WR; Jakob PM
    Z Med Phys; 2017 Dec; 27(4):334-339. PubMed ID: 28431859
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Functional evaluation of transplanted kidneys using arterial spin labeling MRI.
    Heusch P; Wittsack HJ; Blondin D; Ljimani A; Nguyen-Quang M; Martirosian P; Zenginli H; Bilk P; Kröpil P; Heusner TA; Antoch G; Lanzman RS
    J Magn Reson Imaging; 2014 Jul; 40(1):84-9. PubMed ID: 24123319
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of renal allografts function early after transplantation using intravoxel incoherent motion and arterial spin labeling MRI.
    Ren T; Wen CL; Chen LH; Xie SS; Cheng Y; Fu YX; Oesingmann N; de Oliveira A; Zuo PL; Yin JZ; Xia S; Shen W
    Magn Reson Imaging; 2016 Sep; 34(7):908-14. PubMed ID: 27114341
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Arterial Transit Time-corrected Renal Blood Flow Measurement with Pulsed Continuous Arterial Spin Labeling MR Imaging.
    Shimizu K; Kosaka N; Fujiwara Y; Matsuda T; Yamamoto T; Tsuchida T; Tsuchiyama K; Oyama N; Kimura H
    Magn Reson Med Sci; 2017 Jan; 16(1):38-44. PubMed ID: 27170422
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Noninvasive measurement of renal blood flow by magnetic resonance imaging in rats.
    Romero CA; Cabral G; Knight RA; Ding G; Peterson EL; Carretero OA
    Am J Physiol Renal Physiol; 2018 Jan; 314(1):F99-F106. PubMed ID: 28978533
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Non-invasive assessment of placental perfusion in vivo using arterial spin labeling (ASL) MRI: A preclinical study in rats.
    Deloison B; Salomon LJ; Quibel T; Chalouhi GE; Alison M; Balvay D; Autret G; Cuenod CA; Clement O; Siauve N
    Placenta; 2019 Feb; 77():39-45. PubMed ID: 30827354
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent.
    Lüdemann L; Nafz B; Elsner F; Grosse-Siestrup C; Meissler M; Kaufels N; Rehbein H; Persson PB; Michaely HJ; Lengsfeld P; Voth M; Gutberlet M
    Invest Radiol; 2009 Mar; 44(3):125-34. PubMed ID: 19151609
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Renal perfusion 3-T MR imaging: a comparative study of arterial spin labeling and dynamic contrast-enhanced techniques.
    Wu WC; Su MY; Chang CC; Tseng WY; Liu KL
    Radiology; 2011 Dec; 261(3):845-53. PubMed ID: 22095996
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Multi-organ comparison of flow-based arterial spin labeling techniques: Spatially non-selective labeling for cerebral and renal perfusion imaging.
    Franklin SL; Bones IK; Harteveld AA; Hirschler L; van Stralen M; Qin Q; de Boer A; Hoogduin JM; Bos C; van Osch MJP; Schmid S
    Magn Reson Med; 2021 May; 85(5):2580-2594. PubMed ID: 33251644
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Feasibility of Renal Blood Flow Measurement Using
    Nishikawa Y; Takahashi N; Nishikawa S; Shimamoto Y; Nishimori K; Kobayashi M; Kimura H; Tsujikawa T; Kasuno K; Mori T; Kiyono Y; Okazawa H; Iwano M
    Diagnostics (Basel); 2023 May; 13(10):. PubMed ID: 37238171
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Detection of renal allograft fibrosis with MRI: arterial spin labeling outperforms reduced field-of-view IVIM.
    Yu YM; Wang W; Wen J; Zhang Y; Lu GM; Zhang LJ
    Eur Radiol; 2021 Sep; 31(9):6696-6707. PubMed ID: 33738596
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Arterial spin labeling MRI is able to detect early hemodynamic changes in diabetic nephropathy.
    Mora-Gutiérrez JM; Garcia-Fernandez N; Slon Roblero MF; Páramo JA; Escalada FJ; Wang DJ; Benito A; Fernández-Seara MA
    J Magn Reson Imaging; 2017 Dec; 46(6):1810-1817. PubMed ID: 28383796
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Optimization of pseudo-continuous arterial spin labeling for renal perfusion imaging.
    Echeverria-Chasco R; Vidorreta M; Aramendía-Vidaurreta V; Cano D; Escalada J; Garcia-Fernandez N; Bastarrika G; Fernández-Seara MA
    Magn Reson Med; 2021 Mar; 85(3):1507-1521. PubMed ID: 33017483
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Renal plasma flow (RPF) measured with multiple-inversion-time arterial spin labeling (ASL) and tracer kinetic analysis: Validation against a dynamic contrast-enhancement method.
    Conlin CC; Oesingmann N; Bolster B; Huang Y; Lee VS; Zhang JL
    Magn Reson Imaging; 2017 Apr; 37():51-55. PubMed ID: 27864008
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Equilibrium signal intensity mapping, an MRI method for fast mapping of longitudinal relaxation rates and for image enhancement.
    Surányi P; Kiss P; Ruzsics B; Brott BC; Simor T; Elgavish GA
    Magn Reson Imaging; 2007 Jun; 25(5):641-51. PubMed ID: 17540275
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A clinical study of using ROC to compare the efficiency of ASL and BOLD in diagnosis of renal allograft function.
    Peng J; Hong Y; Zhu F; Li Y; Luo S; Lu G
    Transl Androl Urol; 2023 Apr; 12(4):612-621. PubMed ID: 37181240
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Volumetric Arterial Spin-labeled Perfusion Imaging of the Kidneys with a Three-dimensional Fast Spin Echo Acquisition.
    Robson PM; Madhuranthakam AJ; Smith MP; Sun MR; Dai W; Rofsky NM; Pedrosa I; Alsop DC
    Acad Radiol; 2016 Feb; 23(2):144-54. PubMed ID: 26521186
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.