These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 38935120)

  • 1. Induction of fast ventricular tachycardia by a CRT-D device: what is the mechanism?
    Barold SS; Kucher A
    Herzschrittmacherther Elektrophysiol; 2024 Sep; 35(3):219-221. PubMed ID: 38935120
    [No Abstract]   [Full Text] [Related]  

  • 2. Electrical storm of monomorphic ventricular tachycardia after a cardiac-resynchronization-therapy-defibrillator upgrade.
    Kantharia BK; Patel JA; Nagra BS; Ledley GS
    Europace; 2006 Aug; 8(8):625-8. PubMed ID: 16772367
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Inappropriate therapy delivered by a CRT-D for tachycardia with simultaneous atrial and ventricular activation: what is the tachycardia?
    Kaneko Y; Nakajima T; Irie T; Ota M; Kato T; Iijima T; Iizuka T; Kurabayashi M
    Pacing Clin Electrophysiol; 2012 Apr; 35(4):496-8. PubMed ID: 21883313
    [No Abstract]   [Full Text] [Related]  

  • 4. Reduction of inappropriate anti-tachycardia pacing therapies and shocks by a novel suite of detection algorithms in heart failure patients with cardiac resynchronization therapy defibrillators: a historical comparison of a prospective database.
    Lunati M; Proclemer A; Boriani G; Landolina M; Locati E; Rordorf R; Daleffe E; Ricci RP; Catanzariti D; Tomasi L; Gulizia M; Baccillieri MS; Molon G; Gasparini M;
    Europace; 2016 Sep; 18(9):1391-8. PubMed ID: 26826135
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multiple shocks after upgrade of an implantable cardioverter-defibrillator to a cardiac resynchronization therapy-defibrillator device.
    Francisco GM; Sharma S; Dougherty AH; Kantharia BK
    Cardiol J; 2009; 16(5):473-6. PubMed ID: 19753529
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Wide QRS complex tachycardia in a patient with a biventricular implantable cardioverter defibrillator: what is the mechanism?
    Arias MA; Puchol A; Pachón M; Briz C
    J Cardiovasc Electrophysiol; 2014 Mar; 25(3):334-7. PubMed ID: 24237963
    [No Abstract]   [Full Text] [Related]  

  • 7. Response of right ventricular size to treatment with cardiac resynchronization therapy and the risk of ventricular tachyarrhythmias in MADIT-CRT.
    Doyle CL; Huang DT; Moss AJ; Solomon SD; Campbell P; McNitt S; Polonsky S; Barsheshet A; Aktas M; Tompkins C; Zareba W; Goldenberg I
    Heart Rhythm; 2013 Oct; 10(10):1471-7. PubMed ID: 23872690
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Incremental benefit of cardiac resynchronisation therapy with versus without a defibrillator.
    Martens P; Verbrugge FH; Nijst P; Dupont M; Nuyens D; Herendael HV; Rivero-Ayerza M; Tang WH; Mullens W
    Heart; 2017 Dec; 103(24):1977-1984. PubMed ID: 28716973
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ventricular pacing induced ventricular tachycardia in patients with implantable cardioverter defibrillators.
    Roelke M; O'Nunain S; Osswald S; Trouton TG; Harthorne JW; Garan H; Ruskin JN
    Pacing Clin Electrophysiol; 1995 Mar; 18(3 Pt 1):486-91. PubMed ID: 7770372
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A devices' game of thrones: cardiac resynchronization therapy vs. pacemaker.
    Moura-Ferreira S; Gonçalves H; Oliveira M; Primo J; Fonseca P; Ribeiro J; Santos E; Pelicano N; Martins D; Gama V
    Europace; 2017 Dec; 19(12):2042-2046. PubMed ID: 28430911
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Association left ventricular lead and ventricular arrhythmias after upgrade to cardiac resynchronization therapy in patients with implantable cardioverter defibrillators.
    Kawamura M; Arai S; Yoshikawa K; Gokan T; Ogawa K; Ochi A; Onishi Y; Munetsugu Y; Ito H; Onuki T; Kobayashi Y; Shinke T
    Clin Cardiol; 2019 Jul; 42(7):670-677. PubMed ID: 31056759
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effectiveness of Cardiac Resynchronization Therapy by QRS Morphology in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT).
    Zareba W; Klein H; Cygankiewicz I; Hall WJ; McNitt S; Brown M; Cannom D; Daubert JP; Eldar M; Gold MR; Goldberger JJ; Goldenberg I; Lichstein E; Pitschner H; Rashtian M; Solomon S; Viskin S; Wang P; Moss AJ;
    Circulation; 2011 Mar; 123(10):1061-72. PubMed ID: 21357819
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of the right ventricular lead position on clinical outcome and on the incidence of ventricular tachyarrhythmias in patients with CRT-D.
    Kutyifa V; Bloch Thomsen PE; Huang DT; Rosero S; Tompkins C; Jons C; McNitt S; Polonsky B; Shah A; Merkely B; Solomon SD; Moss AJ; Zareba W; Klein HU
    Heart Rhythm; 2013 Dec; 10(12):1770-7. PubMed ID: 23973954
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reverse remodeling and the risk of ventricular tachyarrhythmias in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy).
    Barsheshet A; Wang PJ; Moss AJ; Solomon SD; Al-Ahmad A; McNitt S; Foster E; Huang DT; Klein HU; Zareba W; Eldar M; Goldenberg I
    J Am Coll Cardiol; 2011 Jun; 57(24):2416-23. PubMed ID: 21658562
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Case report: Delayed detection of ventricular tachycardia due to intradevice interactions by implantable atrio-ventricular pacer/cardioverter defibrillator.
    Kantharia BK; Padder FA
    J Interv Card Electrophysiol; 2006 Aug; 16(2):135-8. PubMed ID: 17016683
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy and safety of different antitachycardia pacing sites in the termination of ventricular tachycardia in patients with biventricular implantable cardioverter-defibrillator.
    Haghjoo M; Hajahmadi M; Fazelifar AF; Sadr-Ameli MA
    Europace; 2011 Apr; 13(4):509-13. PubMed ID: 21296776
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Association between frequency of atrial and ventricular ectopic beats and biventricular pacing percentage and outcomes in patients with cardiac resynchronization therapy.
    Ruwald MH; Mittal S; Ruwald AC; Aktas MK; Daubert JP; McNitt S; Al-Ahmad A; Jons C; Kutyifa V; Steinberg JS; Wang P; Moss AJ; Zareba W
    J Am Coll Cardiol; 2014 Sep; 64(10):971-81. PubMed ID: 25190230
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prospective Randomized Evaluation of Implantable Cardioverter-Defibrillator Programming in Patients With a Left Ventricular Assist Device.
    Richardson TD; Hale L; Arteaga C; Xu M; Keebler M; Schlendorf K; Danter M; Shah A; Lindenfeld J; Ellis CR
    J Am Heart Assoc; 2018 Feb; 7(5):. PubMed ID: 29475875
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cardiac resynchronization therapy reduces T-wave alternans in patients with heart failure.
    Hua W; Chen K; Zhou X; Dai Y; Chen R; Wang J; Ding L; Liu Z; Feng T; Yu J; Cheng J; Liu C; Zhang S
    Europace; 2015 Feb; 17(2):281-8. PubMed ID: 25398405
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Atrioventricular sequential pacing by an implantable cardioverter defibrillator during sustained ventricular tachycardia: what is the mechanism?
    Wood MA; Ellenbogen KA; Shepard RK; Clemo HS
    J Cardiovasc Electrophysiol; 2002 Dec; 13(12):1309-10. PubMed ID: 12521353
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.