These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
144 related articles for article (PubMed ID: 38942910)
1. The VRF-L and VRF-GL IOL power calculation methods after radial keratotomy. Voytsekhivskyy OV Eye (Lond); 2024 Oct; 38(15):2947-2954. PubMed ID: 38942910 [TBL] [Abstract][Full Text] [Related]
2. Methods for Intraocular Lens Power Calculation in Cataract Surgery after Radial Keratotomy. Turnbull AMJ; Crawford GJ; Barrett GD Ophthalmology; 2020 Jan; 127(1):45-51. PubMed ID: 31561878 [TBL] [Abstract][Full Text] [Related]
3. Accuracy of Modern Intraocular Lens Formulas in Highly Myopic Eyes Implanted With Plate-Haptic Intraocular Lenses. Mo ER; Chen Z; Feng KE; Zhu Z; Xu J; Zhu C; Chang P; Li J; Zhao YE Am J Ophthalmol; 2024 Sep; 265():105-116. PubMed ID: 38703800 [TBL] [Abstract][Full Text] [Related]
4. Refractive Predictability Using the IOLMaster 700 and Artificial Intelligence-Based IOL Power Formulas Compared to Standard Formulas. Cheng H; Kane JX; Liu L; Li J; Cheng B; Wu M J Refract Surg; 2020 Jul; 36(7):466-472. PubMed ID: 32644169 [TBL] [Abstract][Full Text] [Related]
5. Comparison of the prediction accuracy of 13 formulas in long eyes. Voytsekhivskyy O; Tutchenko L Graefes Arch Clin Exp Ophthalmol; 2023 Sep; 261(9):2575-2583. PubMed ID: 37074410 [TBL] [Abstract][Full Text] [Related]
6. Clinical Accuracy of 18 IOL Power Formulas in 241 Short Eyes. Voytsekhivskyy OV; Hoffer KJ; Savini G; Tutchenko LP; Hipólito-Fernandes D Curr Eye Res; 2021 Dec; 46(12):1832-1843. PubMed ID: 34013799 [TBL] [Abstract][Full Text] [Related]
7. Comparison of formula accuracy for intraocular lens power calculation based on measurements by a swept-source optical coherence tomography optical biometer. Savini G; Hoffer KJ; Balducci N; Barboni P; Schiano-Lomoriello D J Cataract Refract Surg; 2020 Jan; 46(1):27-33. PubMed ID: 32050229 [TBL] [Abstract][Full Text] [Related]
8. Comparison of Newer IOL Power Calculation Methods for Eyes With Previous Radial Keratotomy. Ma JX; Tang M; Wang L; Weikert MP; Huang D; Koch DD Invest Ophthalmol Vis Sci; 2016 Jul; 57(9):OCT162-8. PubMed ID: 27409468 [TBL] [Abstract][Full Text] [Related]
9. Comparison of Intraoperative Aberrometry, OCT-Based IOL Formula, Haigis-L, and Masket Formulae for IOL Power Calculation after Laser Vision Correction. Fram NR; Masket S; Wang L Ophthalmology; 2015 Jun; 122(6):1096-101. PubMed ID: 25766733 [TBL] [Abstract][Full Text] [Related]
10. The effect of ocular biometric factors on the accuracy of various IOL power calculation formulas. Jeong J; Song H; Lee JK; Chuck RS; Kwon JW BMC Ophthalmol; 2017 May; 17(1):62. PubMed ID: 28464806 [TBL] [Abstract][Full Text] [Related]
11. Accuracy of the VRF and VRF-G Intraocular Lens Power Calculation Formulas Using Swept-Source Optical Coherence Tomography Biometry. Voytsekhivskyy OV Clin Ophthalmol; 2023; 17():3663-3672. PubMed ID: 38050557 [TBL] [Abstract][Full Text] [Related]
12. Comparison of the Barrett Universal II, Kane and VRF-G formulas with existing intraocular lens calculation formulas in eyes with short axial lengths. Voytsekhivskyy OV; Tutchenko L; Hipólito-Fernandes D Eye (Lond); 2023 Jan; 37(1):120-126. PubMed ID: 35031707 [TBL] [Abstract][Full Text] [Related]
13. Intraocular lens power calculation in eyes with keratoconus. Savini G; Abbate R; Hoffer KJ; Mularoni A; Imburgia A; Avoni L; D'Eliseo D; Schiano-Lomoriello D J Cataract Refract Surg; 2019 May; 45(5):576-581. PubMed ID: 30799180 [TBL] [Abstract][Full Text] [Related]
14. Accuracy of Traditional and Modern Formulas for Intraocular Lens Power Calculation After Radial Keratotomy Using Standard Keratometry. Helaly HA; Elhady AM; Elnaggar OR Clin Ophthalmol; 2023; 17():2589-2597. PubMed ID: 37671334 [TBL] [Abstract][Full Text] [Related]
15. Intraoperative Aberrometry Versus Preoperative Biometry for IOL Power Selection After Radial Keratotomy: A Prospective Study. Curado SX; Hida WT; Vilar CMC; Ordones VL; Chaves MAP; Tzelikis PF J Refract Surg; 2019 Oct; 35(10):656-661. PubMed ID: 31610007 [TBL] [Abstract][Full Text] [Related]
16. Intraocular Lens Power Selection after Radial Keratotomy: Topography, Manual, and IOLMaster Keratometry Results Using Haigis Formulas. Geggel HS Ophthalmology; 2015 May; 122(5):897-902. PubMed ID: 25601534 [TBL] [Abstract][Full Text] [Related]
17. Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery. Wang L; Spektor T; de Souza RG; Koch DD J Cataract Refract Surg; 2019 Oct; 45(10):1416-1421. PubMed ID: 31399324 [TBL] [Abstract][Full Text] [Related]
18. [Comparison of the accuracy of intraocular lens power calculation formulas based on the new swept-source optical coherence tomography biometry]. Deng XH; Chang PJ; Huang JH; Wang DD; Zhao YY; Ding XX; Zhao YE Zhonghua Yan Ke Za Zhi; 2021 Jul; 57(7):502-511. PubMed ID: 34256470 [No Abstract] [Full Text] [Related]
19. IOL Power Calculation After Radial Keratotomy Using the Haigis and Barrett True-K Formulas. Leite de Pinho Tavares R; de Almeida Ferreira G; Ghanem VC; Ghanem RC J Refract Surg; 2020 Dec; 36(12):832-837. PubMed ID: 33295996 [TBL] [Abstract][Full Text] [Related]
20. Accuracy of intraocular lens calculation formulas based on swept-source OCT biometer in cataract patients with phakic intraocular lens. Zeng Z; Zhu M; Zhang G BMC Ophthalmol; 2024 Aug; 24(1):326. PubMed ID: 39103785 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]