104 related articles for article (PubMed ID: 38954917)
1. Suppressing the HIFU interference in ultrasound guiding images with a diffusion-based deep learning model.
Cai D; Yang K; Liu X; Xu J; Ran Y; Xu Y; Zhou X
Comput Methods Programs Biomed; 2024 Jun; 254():108304. PubMed ID: 38954917
[TBL] [Abstract][Full Text] [Related]
2. Suppressing HIFU interference in ultrasound images using 1D U-Net-based neural networks.
Yang K; Li Q; Liu H; Zeng Q; Cai D; Xu J; Zhou Y; Tsui PH; Zhou X
Phys Med Biol; 2024 Mar; 69(7):. PubMed ID: 38382109
[No Abstract] [Full Text] [Related]
3. Frequency-Domain Robust PCA for Real-Time Monitoring of HIFU Treatment.
Yang K; Li Q; Xu J; Tang MX; Wang Z; Tsui PH; Zhou X
IEEE Trans Med Imaging; 2024 Apr; PP():. PubMed ID: 38578852
[TBL] [Abstract][Full Text] [Related]
4. Adaptive HIFU noise cancellation for simultaneous therapy and imaging using an integrated HIFU/imaging transducer.
Jeong JS; Cannata JM; Shung KK
Phys Med Biol; 2010 Apr; 55(7):1889-902. PubMed ID: 20224162
[TBL] [Abstract][Full Text] [Related]
5. Ultrasound Monitoring of Simultaneous high-intensity focused ultrasound (HIFU) therapy using minimum-peak-sidelobe coded excitation.
Shen CC; Wu NH
Ultrasonics; 2024 Mar; 138():107224. PubMed ID: 38134515
[TBL] [Abstract][Full Text] [Related]
6. Adaptive singular value decomposition filtering of high-intensity focused ultrasound interference enables real-time ultrasound-guided therapy.
Lee H; Chung E; Yoon H; Song TK
Ultrasonography; 2023 Apr; 42(2):343-353. PubMed ID: 36935600
[TBL] [Abstract][Full Text] [Related]
7. Pulse compression technique for simultaneous HIFU surgery and ultrasonic imaging: a preliminary study.
Jeong JS; Chang JH; Shung KK
Ultrasonics; 2012 Aug; 52(6):730-9. PubMed ID: 22356771
[TBL] [Abstract][Full Text] [Related]
8. Harmonic Motion Imaging-Guided Focused Ultrasound Ablation: Comparison of Three Focused Ultrasound Interference Filtering Methods.
Li XJ; Hossain MM; Lee SA; Saharkhiz N; Konofagou E
Ultrasound Med Biol; 2024 Jan; 50(1):119-127. PubMed ID: 37872031
[TBL] [Abstract][Full Text] [Related]
9. Dynamic changes of integrated backscatter, attenuation coefficient and bubble activities during high-intensity focused ultrasound (HIFU) treatment.
Zhang S; Wan M; Zhong H; Xu C; Liao Z; Liu H; Wang S
Ultrasound Med Biol; 2009 Nov; 35(11):1828-44. PubMed ID: 19716225
[TBL] [Abstract][Full Text] [Related]
10. A region-based segmentation method for ultrasound images in HIFU therapy.
Zhang D; Liu Y; Yang Y; Xu M; Yan Y; Qin Q
Med Phys; 2016 Jun; 43(6):2975-2989. PubMed ID: 27277046
[TBL] [Abstract][Full Text] [Related]
11. Diffusion-weighted MRI with deep learning for visualizing treatment results of MR-guided HIFU ablation of uterine fibroids.
Slotman DJ; Bartels LW; Zijlstra A; Verpalen IM; van Osch JAC; Nijholt IM; Heijman E; van 't Veer-Ten Kate M; de Boer E; van den Hoed RD; Froeling M; Boomsma MF
Eur Radiol; 2023 Jun; 33(6):4178-4188. PubMed ID: 36472702
[TBL] [Abstract][Full Text] [Related]
12. Real-time monitoring of HIFU treatment using pulse inversion.
Song JH; Yoo Y; Song TK; Chang JH
Phys Med Biol; 2013 Aug; 58(15):5333-50. PubMed ID: 23863761
[TBL] [Abstract][Full Text] [Related]
13. Non-Invasive Targeted Peripheral Nerve Ablation Using 3D MR Neurography and MRI-Guided High-Intensity Focused Ultrasound (MR-HIFU): Pilot Study in a Swine Model.
Huisman M; Staruch RM; Ladouceur-Wodzak M; van den Bosch MA; Burns DK; Chhabra A; Chopra R
PLoS One; 2015; 10(12):e0144742. PubMed ID: 26659073
[TBL] [Abstract][Full Text] [Related]
14. Design and evaluation of a transesophageal HIFU probe for ultrasound-guided cardiac ablation: simulation of a HIFU mini-maze procedure and preliminary ex vivo trials.
Constanciel E; N'Djin WA; Bessière F; Chavrier F; Grinberg D; Vignot A; Chevalier P; Chapelon JY; Lafon C
IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Sep; 60(9):1868-83. PubMed ID: 24658718
[TBL] [Abstract][Full Text] [Related]
15. Quantitative measurement and real-time tracking of high intensity focused ultrasound using phase-sensitive optical coherence tomography: Feasibility study.
Le N; Song S; Nabi G; Wang R; Huang Z
Int J Hyperthermia; 2016 Sep; 32(6):713-22. PubMed ID: 27380284
[TBL] [Abstract][Full Text] [Related]
16. High-Intensity Focused Ultrasound Lesion Detection Using Adaptive Compressive Sensing Based on Empirical Mode Decomposition.
Ghasemifard H; Behnam H; Tavakkoli J
J Med Signals Sens; 2019; 9(1):24-32. PubMed ID: 30967987
[TBL] [Abstract][Full Text] [Related]
17. Using the acoustic interference pattern to locate the focus of a high-intensity focused ultrasound (HIFU) transducer.
Wu CC; Chen CN; Ho MC; Chen WS; Lee PH
Ultrasound Med Biol; 2008 Jan; 34(1):137-46. PubMed ID: 17720300
[TBL] [Abstract][Full Text] [Related]
18. Real-time monitoring of high-intensity focused ultrasound thermal therapy using the manifold learning method.
Rangraz P; Behnam H; Sobhebidari P; Tavakkoli J
Ultrasound Med Biol; 2014 Dec; 40(12):2841-50. PubMed ID: 25438863
[TBL] [Abstract][Full Text] [Related]
19. Technical note: Evaluation of the acoustic radiation force imaging for predicting HIFU focus with in vitro and ex vivo experiments.
Feng L; Shi X; Zhou F; Chen Y; Zhou X
Med Phys; 2023 Sep; 50(9):5449-5459. PubMed ID: 37345709
[TBL] [Abstract][Full Text] [Related]
20. Multi-parametric monitoring and assessment of high-intensity focused ultrasound (HIFU) boiling by harmonic motion imaging for focused ultrasound (HMIFU): an ex vivo feasibility study.
Hou GY; Marquet F; Wang S; Konofagou EE
Phys Med Biol; 2014 Mar; 59(5):1121-45. PubMed ID: 24556974
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]