These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 38969693)

  • 1. Evaluating three internal fixation techniques for Pauwels III femoral neck fractures via finite element analysis.
    Li N; Cheng KY; Fan J; Li Y; Yang M; Zhu S; Jiang X
    Sci Rep; 2024 Jul; 14(1):15519. PubMed ID: 38969693
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical effects of internal fixation with self-lock compression anti-rotation blade for Pauwels type III femoral neck fractures: a comparative finite element analysis.
    Huang BX; Zhan SZ; Yang M; Zhang DY
    BMC Musculoskelet Disord; 2023 Apr; 24(1):292. PubMed ID: 37059976
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bio-mechanical effects of femoral neck system versus cannulated screws on treating young patients with Pauwels type III femoral neck fractures: a finite element analysis.
    Fan X; Zhou Y; Dai S; Lao K; Zhang Q; Yu T
    BMC Musculoskelet Disord; 2024 Jan; 25(1):83. PubMed ID: 38245678
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Finite element analysis of femoral neck system in the treatment of Pauwels type III femoral neck fracture.
    Teng Y; Zhang Y; Guo C
    Medicine (Baltimore); 2022 Jul; 101(28):e29450. PubMed ID: 35839002
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Finite Element Analysis of Six Internal Fixations in the Treatment of Pauwels Type III Femoral Neck Fracture.
    Sun X; Han Z; Cao D; Han C; Xie M; Zeng X; Dong Q
    Orthop Surg; 2024 Jul; 16(7):1695-1709. PubMed ID: 38747083
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pre-sliding of femoral neck system improves fixation stability in pauwels type III femoral neck fracture: a finite element analysis.
    Cha Y; Chung JY; Jung CH; Kim JW; Lee J; Yoo JI; Kim JT; Jeon Y
    BMC Musculoskelet Disord; 2023 Jun; 24(1):506. PubMed ID: 37344858
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical study on parallel cannulated compression screw combined with medial buttress plate fixation and F-type cannulated compression screw fixation in Pauwels III femoral neck fracture:A finite element analysis.
    Wang J; Gao Y; Song D; Ni J
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2022 Aug; 47(8):1143-1153. PubMed ID: 36097783
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures.
    Ma J; Zhao Z; Zhi X; Wang H; Wang W
    BMC Musculoskelet Disord; 2022 Nov; 23(1):1030. PubMed ID: 36447275
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture.
    Tianye L; Peng Y; Jingli X; QiuShi W; GuangQuan Z; Wei H; Qingwen Z
    Biomed Pharmacother; 2019 Apr; 112():108658. PubMed ID: 30970508
    [TBL] [Abstract][Full Text] [Related]  

  • 10. How to choose the suitable FNS specification in young patients with femoral neck fracture: A finite element analysis.
    Fan Z; Huang Y; Su H; Jiang T
    Injury; 2021 Aug; 52(8):2116-2125. PubMed ID: 34154816
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical comparison of femoral neck system and cannulated screws coupled with medial plate for treating Pauwels III femoral neck fractures.
    Nan C; Li Y; Liu Y; Ma L; Ma Z
    Technol Health Care; 2023; 31(4):1161-1170. PubMed ID: 36872803
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Finite Element Analysis of Femoral Neck Fracture Treated with Bidirectional Compression-Limited Sliding Screw.
    Huang H; Feng Z; Wang W; Yang C; Liao J; Ouyang J
    Med Sci Monit; 2021 Mar; 27():e929163. PubMed ID: 33782376
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical study of femoral neck system for young patients with nonanatomically reduced femoral neck fractures: a finite element.
    Fan Z; Chen P; Yu X; Li X; Su H; Chen H; Yang B; Qi J; Wang H
    BMC Musculoskelet Disord; 2023 Jan; 24(1):54. PubMed ID: 36681804
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical evaluation of the reconstruction of the calcar femorale in femoral neck fractures: a comparative finite element analysis.
    Gao Z; Ma J; Wang Y; Lu B; Bai H; Sun L; Jin H; Zhang Z; Ma X
    J Int Med Res; 2022 Jul; 50(7):3000605221112043. PubMed ID: 35899621
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical changes in the proximal femur before and after removal of femoral neck system.
    Nan C; Liu Y; Zhang D; Qin Y; Yu H; Ma Z
    J Orthop Surg Res; 2024 May; 19(1):290. PubMed ID: 38735949
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical study of two alternative methods for the treatment of vertical femoral neck fractures - A finite element analysis.
    Xia Y; Zhang W; Hu H; Yan L; Zhan S; Wang J
    Comput Methods Programs Biomed; 2021 Nov; 211():106409. PubMed ID: 34560605
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Femoral neck system and cannulated compression screws in the treatment of non-anatomical reduction Pauwels type-III femoral neck fractures: A finite element analysis.
    Zhong Z; Lan X; Xiang Z; Duan X
    Clin Biomech (Bristol, Avon); 2023 Aug; 108():106060. PubMed ID: 37536196
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Biomechanical analysis of four internal fixations for Pauwels Ⅲ femoral neck fractures with defects].
    Su ZH; Tan HL; Xu ZH; Li PF; Wang YQ; Li S; Ni M
    Zhongguo Gu Shang; 2023 Mar; 36(3):255-61. PubMed ID: 36946019
    [TBL] [Abstract][Full Text] [Related]  

  • 19. New fixation method for Pauwels type III femoral neck fracture: a finite element analysis of sliding hip screw, L-shaped, and L-shaped with medial plate.
    Freitas A; Bontempo RL; Azevedo FAR; Battaglion LR; Giordano MN; Barin FR; Giordano V
    Eur J Orthop Surg Traumatol; 2021 Aug; 31(6):1069-1075. PubMed ID: 33389052
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The significance of reduction of valgus-intercalated femoral neck fracture with valgus angle > 15°and the selection of internal fixation by finite element analysis.
    Yusufu A; Yusupu T; Haibier A; Abulaiti A; Ran J
    BMC Musculoskelet Disord; 2024 Jan; 25(1):79. PubMed ID: 38245700
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.