These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 38971336)

  • 1. A rapid quantitative UPLC-MS/MS method for analysis of key regulatory oxysterols in biological samples for liver cancer.
    Lu L; Li J; Zhang L; Zhang Y; Li Z; Lan J; Zeng R; Fang S; Zhang T; Ding Y
    J Steroid Biochem Mol Biol; 2024 Oct; 243():106577. PubMed ID: 38971336
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A quantitative LC-MS/MS method for analysis of mitochondrial -specific oxysterol metabolism.
    Borah K; Rickman OJ; Voutsina N; Ampong I; Gao D; Baple EL; Dias IH; Crosby AH; Griffiths HR
    Redox Biol; 2020 Sep; 36():101595. PubMed ID: 32574926
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reproducibility of serum oxysterols and lanosterol among postmenopausal women: Results from EPIC-Heidelberg.
    Lu DL; Sookthai D; Le Cornet C; Katzke VA; Johnson TS; Kaaks R; Fortner RT
    Clin Biochem; 2018 Feb; 52():117-122. PubMed ID: 29108727
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fast LC-MS/MS analysis of free oxysterols derived from reactive oxygen species in human plasma and carotid plaque.
    Helmschrodt C; Becker S; Schröter J; Hecht M; Aust G; Thiery J; Ceglarek U
    Clin Chim Acta; 2013 Oct; 425():3-8. PubMed ID: 23827692
    [TBL] [Abstract][Full Text] [Related]  

  • 5. LC-ESI-MS/MS quantification of 4β-hydroxycholesterol and cholesterol in plasma samples of limited volume.
    Xu Y; Yuan Y; Smith L; Edom R; Weng N; Mamidi R; Silva J; Evans DC; Lim HK
    J Pharm Biomed Anal; 2013 Nov; 85():145-54. PubMed ID: 23948760
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Elevated oxysterol levels in human and mouse livers reflect nonalcoholic steatohepatitis.
    Raselli T; Hearn T; Wyss A; Atrott K; Peter A; Frey-Wagner I; Spalinger MR; Maggio EM; Sailer AW; Schmitt J; Schreiner P; Moncsek A; Mertens J; Scharl M; Griffiths WJ; Bueter M; Geier A; Rogler G; Wang Y; Misselwitz B
    J Lipid Res; 2019 Jul; 60(7):1270-1283. PubMed ID: 31113816
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Highly sensitive quantification of key regulatory oxysterols in biological samples by LC-ESI-MS/MS.
    Honda A; Yamashita K; Hara T; Ikegami T; Miyazaki T; Shirai M; Xu G; Numazawa M; Matsuzaki Y
    J Lipid Res; 2009 Feb; 50(2):350-7. PubMed ID: 18815436
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quantification of oxysterols in human plasma and red blood cells by liquid chromatography high-resolution tandem mass spectrometry.
    Pataj Z; Liebisch G; Schmitz G; Matysik S
    J Chromatogr A; 2016 Mar; 1439():82-88. PubMed ID: 26607314
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simultaneous determination of oxysterols, cholesterol and 25-hydroxy-vitamin D3 in human plasma by LC-UV-MS.
    Narayanaswamy R; Iyer V; Khare P; Bodziak ML; Badgett D; Zivadinov R; Weinstock-Guttman B; Rideout TC; Ramanathan M; Browne RW
    PLoS One; 2015; 10(4):e0123771. PubMed ID: 25875771
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A pilot study of the association between maternal mid-pregnancy cholesterol and oxysterol concentrations and labor duration.
    Rideout TC; Wallace J; Wen X; Barnabei VM; Kong KL; Browne RW
    Lipids Health Dis; 2023 Mar; 22(1):37. PubMed ID: 36906556
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Method development for the determination of 24S-hydroxycholesterol in human plasma without derivatization by high-performance liquid chromatography with tandem mass spectrometry in atmospheric pressure chemical ionization mode.
    Sugimoto H; Kakehi M; Satomi Y; Kamiguchi H; Jinno F
    J Sep Sci; 2015 Oct; 38(20):3516-24. PubMed ID: 26249017
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rapid LC-MS/MS method for the determination of 4-hydroxycholesterol/cholesterol ratio in serum as endogenous biomarker for CYP3A activity in human and foals.
    Hasan M; Siegmund W; Oswald S
    J Chromatogr B Analyt Technol Biomed Life Sci; 2016 Oct; 1033-1034():193-199. PubMed ID: 27565568
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Discovering oxysterols in plasma: a window on the metabolome.
    Griffiths WJ; Hornshaw M; Woffendin G; Baker SF; Lockhart A; Heidelberger S; Gustafsson M; Sjövall J; Wang Y
    J Proteome Res; 2008 Aug; 7(8):3602-12. PubMed ID: 18605750
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fast liquid chromatography-mass spectrometry reveals side chain oxysterol heterogeneity in breast cancer tumour samples.
    Solheim S; Hutchinson SA; Lundanes E; Wilson SR; Thorne JL; Roberg-Larsen H
    J Steroid Biochem Mol Biol; 2019 Sep; 192():105309. PubMed ID: 30779932
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Esterification of 4β-hydroxycholesterol and other oxysterols in human plasma occurs independently of LCAT.
    Yamamuro D; Yamazaki H; Osuga JI; Okada K; Wakabayashi T; Takei A; Takei S; Takahashi M; Nagashima S; Holleboom AG; Kuroda M; Bujo H; Ishibashi S
    J Lipid Res; 2020 Sep; 61(9):1287-1299. PubMed ID: 32561542
    [TBL] [Abstract][Full Text] [Related]  

  • 16. LC-MS/MS profiling of colon oxysterols and cholesterol precursors in mouse model of ulcerative colitis.
    Lin J; Yang X; Wang A; Yang J; Zheng Y; Dong H; Tian Y; Zhang Z; Wang M; Song R
    J Chromatogr A; 2024 May; 1722():464865. PubMed ID: 38598891
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection of dihydroxycholesterols in human plasma using HPLC-ESI-MS/MS.
    Karuna R; Christen I; Sailer AW; Bitsch F; Zhang J
    Steroids; 2015 Jul; 99(Pt B):131-8. PubMed ID: 25683891
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of 24S- and 27-hydroxycholesterol in plasma by high-performance liquid chromatography-mass spectrometry.
    Burkard I; Rentsch KM; von Eckardstein A
    J Lipid Res; 2004 Apr; 45(4):776-81. PubMed ID: 14729854
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quantification of Oxysterol Nuclear Receptor Ligands by LC/MS/MS.
    Magomedova L; Cummins CL
    Methods Mol Biol; 2019; 1951():1-14. PubMed ID: 30825140
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Involvement of 27-Hydroxycholesterol in Mitotane Action on Adrenocortical Carcinoma.
    Germano A; Rossin D; Leoni V; Iaia N; Saba L; Basile V; Puglisi S; Caccia C; Poli G; Biasi F; Terzolo M
    Cells; 2020 Apr; 9(4):. PubMed ID: 32260362
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.