These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 38986246)

  • 1. Mode conversion of fundamental guided ultrasonic wave modes at part-thickness crack-like defects.
    Li L; Fromme P
    Ultrasonics; 2024 Aug; 142():107399. PubMed ID: 38986246
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analysis of high frequency guided wave scattering at a fastener hole with a view to fatigue crack detection.
    Masserey B; Fromme P
    Ultrasonics; 2017 Apr; 76():78-86. PubMed ID: 28086108
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Air coupled ultrasonic inspection with Lamb waves in plates showing mode conversion.
    Römmeler A; Zolliker P; Neuenschwander J; van Gemmeren V; Weder M; Dual J
    Ultrasonics; 2020 Jan; 100():105984. PubMed ID: 31479964
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Meta-structure enhanced second harmonic S
    Liu Z; Shan S; Cheng L
    Ultrasonics; 2024 Apr; 139():107295. PubMed ID: 38489848
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 2D Analytical Model for the Directivity Prediction of Ultrasonic Contact Type Transducers in the Generation of Guided Waves.
    Tiwari KA; Raisutis R; Mazeika L; Samaitis V
    Sensors (Basel); 2018 Mar; 18(4):. PubMed ID: 29587472
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Damage localization method for plates based on the time reversal of the mode-converted Lamb waves.
    Mori N; Biwa S; Kusaka T
    Ultrasonics; 2019 Jan; 91():19-29. PubMed ID: 30031966
    [TBL] [Abstract][Full Text] [Related]  

  • 7. S0 Lamb Mode Scattering Studies in Laminated Composite Plate Structures with Surface Breaking Cracks: Insights into Crack Opening Behavior.
    Gupta S; Rajagopal P
    Ultrasonics; 2023 Mar; 129():106901. PubMed ID: 36473285
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Wave mode extraction from multimodal wave signals in an orthotropic composite plate.
    Ratassepp M; Fan Z; Lasn K
    Ultrasonics; 2016 Sep; 71():223-230. PubMed ID: 27403641
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Lamb wave propagation in monocrystalline silicon wafers.
    Fromme P; Pizzolato M; Robyr JL; Masserey B
    J Acoust Soc Am; 2018 Jan; 143(1):287. PubMed ID: 29390792
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multi-Mode Electromagnetic Ultrasonic Lamb Wave Tomography Imaging for Variable-Depth Defects in Metal Plates.
    Huang S; Zhang Y; Wang S; Zhao W
    Sensors (Basel); 2016 May; 16(5):. PubMed ID: 27144571
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of Welded Lap Joints Using Ultrasonic Guided Waves.
    Altammar H; Faseeulla Khan M
    Sensors (Basel); 2024 Feb; 24(5):. PubMed ID: 38474922
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultrasonic guided wave scattering in a plate overlap.
    Song WJ; Rose JL; Galán JM; Abascal R
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 May; 52(5):892-903. PubMed ID: 16048190
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interaction of ultrasonic guided waves with interfacial debonding in a stiffened composite plate under variable temperature and operational conditions.
    Prakash Kalgutkar A; Banerjee S
    Ultrasonics; 2024 Aug; 142():107378. PubMed ID: 38865788
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mode Conversion Behavior of Guided Wave in a Pipe Inspection System Based on a Long Waveguide.
    Sun F; Sun Z; Chen Q; Murayama R; Nishino H
    Sensors (Basel); 2016 Oct; 16(10):. PubMed ID: 27775580
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mode selection for corrosion detection in pipes and vessels via guided wave tomography.
    Huthwaite P; Ribichini R; Cawley P; Lowe MJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Jun; 60(6):1165-77. PubMed ID: 25004479
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transmission analysis of ultrasonic Lamb mode conversion in a plate with partial-thickness notch.
    Xu K; Ta D; Su Z; Wang W
    Ultrasonics; 2014 Jan; 54(1):395-401. PubMed ID: 23916666
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection of a Submillimeter Notch-Type Defect at Multiple Orientations by a Lamb Wave A
    Capineri L; Taddei L; Marino Merlo E
    Sensors (Basel); 2024 Mar; 24(6):. PubMed ID: 38544191
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Propagation characteristics of ultrasonic weld-guided waves in Friction stir welding joint of same material.
    Wang Y; Gao T; Liu D; Sun H; Miao B; Qing X
    Ultrasonics; 2020 Mar; 102():106058. PubMed ID: 31948805
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Symmetric low-frequency feature-guided ultrasonic waves in thin plates with transverse bends.
    Ramdhas A; Pattanayak RK; Balasubramaniam K; Rajagopal P
    Ultrasonics; 2015 Feb; 56():232-42. PubMed ID: 25220805
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-Precision Corrosion Detection via SH1 Guided Wave Based on Full Waveform Inversion.
    Wen J; Jiang C; Chen H
    Sensors (Basel); 2023 Dec; 23(24):. PubMed ID: 38139749
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.