These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 3898927)

  • 21. Analysis of the Weinbaum-Jiji model of blood flow in the canine kidney cortex for self-heated thermistors.
    Valvano JW; Nho S; Anderson GT
    J Biomech Eng; 1994 May; 116(2):201-7. PubMed ID: 8078327
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Measurement of thermal properties of living tissue in vivo].
    Che C; He J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 1997 Jun; 14(2):188-92. PubMed ID: 9817652
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A technique for measuring the thermal conductivity and evaluating the "apparent conductivity" concept in biomaterials.
    Arkin H; Holmes KR; Chen MM
    J Biomech Eng; 1989 Nov; 111(4):276-82. PubMed ID: 2486365
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Investigation of the thermal and tissue injury behaviour in microwave thermal therapy using a porcine kidney model.
    He X; McGee S; Coad JE; Schmidlin F; Iaizzo PA; Swanlund DJ; Kluge S; Rudie E; Bischof JC
    Int J Hyperthermia; 2004 Sep; 20(6):567-93. PubMed ID: 15370815
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Computer-based system for continuous on-line measurements of tissue blood perfusion.
    Arkin H; Holmes KR; Chen MM
    J Biomed Eng; 1987 Jan; 9(1):38-45. PubMed ID: 3795903
    [TBL] [Abstract][Full Text] [Related]  

  • 26. An advanced computational bioheat transfer model for a human body with an embedded systemic circulation.
    Coccarelli A; Boileau E; Parthimos D; Nithiarasu P
    Biomech Model Mechanobiol; 2016 Oct; 15(5):1173-90. PubMed ID: 26707859
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A thermal method for the determination of tissue blood flow.
    McCaffrey TV; McCook RD
    J Appl Physiol; 1975 Jul; 39(1):170-3. PubMed ID: 125256
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Blood flow and heat transfer in Walker 256 mammary carcinoma.
    Jain RK; Grantham FH; Gullino PM
    J Natl Cancer Inst; 1979 Apr; 62(4):927-33. PubMed ID: 285296
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Evaluation of local tissue blood flow by continuous direct measurement of thermal conductivity.
    Levy L; Graichen H; Stolwijk JA; Calabresi M
    J Appl Physiol; 1967 May; 22(5):1026-9. PubMed ID: 6025742
    [No Abstract]   [Full Text] [Related]  

  • 30. Self-heated thermistor measurements of perfusion.
    Anderson GT; Valvano JW; Santos RR
    IEEE Trans Biomed Eng; 1992 Sep; 39(9):877-85. PubMed ID: 1473816
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Thermal pulse decay method for simultaneous measurement of local thermal conductivity and blood perfusion: a theoretical analysis.
    Arkin H; Holmes KR; Chen MM; Bottje WG
    J Biomech Eng; 1986 Aug; 108(3):208-14. PubMed ID: 3747464
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Effects of probe configuration on the measurement of bio-tissue thermal physical parameters using step-temperature technique].
    Yang K; Liu W; Luo Q
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Oct; 24(5):1001-7. PubMed ID: 18027684
    [TBL] [Abstract][Full Text] [Related]  

  • 33. On the relationship between blood perfusion, metabolism and temperature in biological tissue heat balance.
    Shitzer A; Kleiner MK
    J Biomech Eng; 1980 May; 102(2):162-9. PubMed ID: 7412240
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Finite volume analysis of temperature effects induced by active MRI implants: 2. Defects on active MRI implants causing hot spots.
    Busch MH; Vollmann W; Grönemeyer DH
    Biomed Eng Online; 2006 May; 5():35. PubMed ID: 16729878
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Use of a thermal pulse decay system to assess avian renal blood flow during reduced renal arterial perfusion pressure.
    Wideman RF; Glahn RP; Bottje WG; Holmes KR
    Am J Physiol; 1992 Jan; 262(1 Pt 2):R90-8. PubMed ID: 1733344
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The simultaneous measurement of thermal conductivity, thermal diffusivity, and perfusion in small volumes of tissue.
    Valvano JW; Allen JT; Bowman HF
    J Biomech Eng; 1984 Aug; 106(3):192-7. PubMed ID: 6492763
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effects of atrial natriuretic peptide on regional renal blood flow measured by a thermal diffusion technique.
    Tsuchiya K; Sanaka T; Nitta K; Ando A; Sugino N
    Jpn J Exp Med; 1989 Feb; 59(1):27-35. PubMed ID: 2525630
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The transient thermal clearance method for regional blood flow measurement--the influence of tissue heat conduction.
    Nitzan M; Mahler Y; Roberts VC
    Clin Phys Physiol Meas; 1988 Nov; 9(4):339-46. PubMed ID: 3233888
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Microwave method of determining cerebral blood flow].
    Gabrielian ES; Khachatrian LA; Nalbandian SG; Grigorian FA
    Biull Eksp Biol Med; 1987 May; 103(5):625-7. PubMed ID: 3593940
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A sensitivity analysis of the Thermal Pulse Decay method for measurement of local tissue conductivity and blood perfusion.
    Arkin H; Holmes KR; Chen MM
    J Biomech Eng; 1986 Feb; 108(1):54-8. PubMed ID: 3959553
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.