These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 38994799)

  • 1. A Modular Variable Temperature FT-IMS Instrument Optimized for Gas-Phase Ion Chemistry Applications.
    Schramm HM; Cabrera ER; Greer C; Clowers BH
    J Am Soc Mass Spectrom; 2024 Aug; 35(8):1883-1890. PubMed ID: 38994799
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of Gas-Phase Ion Mobility Coefficients Using Voltage Sweep Multiplexing.
    Reinecke T; Davis AL; Clowers BH
    J Am Soc Mass Spectrom; 2019 Jun; 30(6):977-986. PubMed ID: 30989619
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Buffer gas additives (modifiers/shift reagents) in ion mobility spectrometry: Applications, predictions of mobility shifts, and influence of interaction energy and structure.
    Fernandez-Maestre R
    J Mass Spectrom; 2018 Jul; 53(7):598-613. PubMed ID: 29689602
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Note: Buffer gas temperature inhomogeneities and design of drift-tube ion mobility spectrometers: Warnings for real-world applications by non-specialists.
    Fernandez-Maestre R
    Rev Sci Instrum; 2017 Sep; 88(9):096104. PubMed ID: 28964182
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Characterization of TATP gas phase product ion chemistry via isotope labeling experiments using ion mobility spectrometry interfaced with a triple quadrupole mass spectrometer.
    Tomlinson-Phillips J; Wooten A; Kozole J; Deline J; Beresford P; Stairs J
    Talanta; 2014 Sep; 127():152-62. PubMed ID: 24913870
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Planning Implications Related to Sterilization-Sensitive Science Investigations Associated with Mars Sample Return (MSR).
    Velbel MA; Cockell CS; Glavin DP; Marty B; Regberg AB; Smith AL; Tosca NJ; Wadhwa M; Kminek G; Meyer MA; Beaty DW; Carrier BL; Haltigin T; Hays LE; Agee CB; Busemann H; Cavalazzi B; Debaille V; Grady MM; Hauber E; Hutzler A; McCubbin FM; Pratt LM; Smith CL; Summons RE; Swindle TD; Tait KT; Udry A; Usui T; Westall F; Zorzano MP
    Astrobiology; 2022 Jun; 22(S1):S112-S164. PubMed ID: 34904892
    [TBL] [Abstract][Full Text] [Related]  

  • 7. New High Resolution Ion Mobility Mass Spectrometer Capable of Measurements of Collision Cross Sections from 150 to 520 K.
    Ujma J; Giles K; Morris M; Barran PE
    Anal Chem; 2016 Oct; 88(19):9469-9478. PubMed ID: 27573618
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of an ion mobility spectrometer for use in an atmospheric pressure ionization ion mobility spectrometer/mass spectrometer instrument for fast screening analysis.
    Sysoev A; Adamov A; Viidanoja J; Ketola RA; Kostiainen R; Kotiaho T
    Rapid Commun Mass Spectrom; 2004; 18(24):3131-9. PubMed ID: 15565719
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Field-Dependent Reduced Ion Mobilities of Positive and Negative Ions in Air and Nitrogen in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS).
    Allers M; Kirk AT; Schaefer C; Erdogdu D; Wissdorf W; Benter T; Zimmermann S
    J Am Soc Mass Spectrom; 2020 Oct; 31(10):2191-2201. PubMed ID: 32865400
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Deducing Proton-Bound Heterodimer Association Energies from Shifts in Ion Mobility Arrival Time Distributions.
    Kwantwi-Barima P; Hogan CJ; Clowers BH
    J Phys Chem A; 2019 Apr; 123(13):2957-2965. PubMed ID: 30844278
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of IMS drift tube temperature on the peak shape of high boiling fragrance compounds towards allergen detection in complex cosmetic products and essential oils.
    Capitain CC; Zischka M; Sirkeci C; Weller P
    Talanta; 2023 May; 257():124397. PubMed ID: 36858010
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Coupling of capillary electrophoresis with electrospray ionization multiplexing ion mobility spectrometry.
    Guo J; Li G; Zhang H; Jia X; Meng Q; Liu W
    Electrophoresis; 2019 Jul; 40(12-13):1639-1647. PubMed ID: 30892711
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Implementation of an Open-Source Multiplexing Ion Gate Control for High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS).
    Naylor CN; Clowers BH; Schlottmann F; Solle N; Zimmermann S
    J Am Soc Mass Spectrom; 2023 Jul; 34(7):1283-1294. PubMed ID: 37276587
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Rapid screening of 14 antibacterial drugs in anti-acne cosmetics using ion mobility spectrometry coupled with solid-phase extraction].
    Xue G; Wang Q; Cao L; Sun J; Yang G; Feng Y; Fang F
    Se Pu; 2022 Dec; 40(12):1119-1127. PubMed ID: 36450352
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ion mobility spectrometry-mass spectrometry performance using electrodynamic ion funnels and elevated drift gas pressures.
    Baker ES; Clowers BH; Li F; Tang K; Tolmachev AV; Prior DC; Belov ME; Smith RD
    J Am Soc Mass Spectrom; 2007 Jul; 18(7):1176-87. PubMed ID: 17512752
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ion mobility spectrometry experiments should be carried out at high temperatures to reduce uncertainties in the measurement of reduced mobilities.
    Fernandez-Maestre R; Daza MC
    Anal Methods; 2021 Jul; 13(25):2878-2887. PubMed ID: 34100038
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ion Mobility Shift of Isotopologues in a High Kinetic Energy Ion Mobility Spectrometer (HiKE-IMS) at Elevated Effective Temperatures.
    Schaefer C; Kirk AT; Allers M; Zimmermann S
    J Am Soc Mass Spectrom; 2020 Oct; 31(10):2093-2101. PubMed ID: 32875796
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effective temperature of ions in traveling wave ion mobility spectrometry.
    Morsa D; Gabelica V; De Pauw E
    Anal Chem; 2011 Jul; 83(14):5775-82. PubMed ID: 21682304
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Studies of negative ions by collision-induced decomposition and hydrogen-deuterium exchange techniques.
    Hunt DF; Sethi SK; Shabanowitz J
    Environ Health Perspect; 1980 Jun; 36():33-8. PubMed ID: 7428745
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ion Mobility, Hydrogen/Deuterium Exchange, and Isotope Scrambling: Tools to Aid Compound Identification in 'Omics Mixtures.
    Maleki H; Maurer MM; Ronaghi N; Valentine SJ
    Anal Chem; 2017 Jun; 89(12):6399-6407. PubMed ID: 28505408
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.