  • 1. Development and Evaluation of a Reusable, Force Measuring Tool for the Robot-Assisted Insertion of Cochlear Implant Electrode Arrays.
    Aebischer P; Sarbach B; Weder S; Mantokoudis G; Caversaccio M; Anschuetz L
    IEEE Trans Biomed Eng; 2024 Jul; PP():. PubMed ID: 38995714
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative in-vitro assessment of a novel robot-assisted system for cochlear implant electrode insertion.
    Aebischer P; Anschuetz L; Caversaccio M; Mantokoudis G; Weder S
    Int J Comput Assist Radiol Surg; 2024 Oct; ():. PubMed ID: 39352456
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Sleeve-Based, Micromotion Avoiding, Retractable and Tear-Opening (SMART) Insertion Tool for Cochlear Implantation.
    Aebischer P; Weder S; Mantokoudis G; Vischer M; Caversaccio M; Wimmer W
    IEEE Trans Biomed Eng; 2023 Mar; 70(3):860-866. PubMed ID: 36063524
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of Insertion Forces and Cochlea Trauma Following Robotics-Assisted Cochlear Implant Electrode Array Insertion.
    Kaufmann CR; Henslee AM; Claussen A; Hansen MR
    Otol Neurotol; 2020 Jun; 41(5):631-638. PubMed ID: 32604327
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Robotics, automation, active electrode arrays, and new devices for cochlear implantation: A contemporary review.
    De Seta D; Daoudi H; Torres R; Ferrary E; Sterkers O; Nguyen Y
    Hear Res; 2022 Feb; 414():108425. PubMed ID: 34979455
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement and Mitigation of Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion.
    Banakis Hartl RM; Greene NT
    Otol Neurotol; 2022 Feb; 43(2):174-182. PubMed ID: 34753876
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Tool to Enable Intraoperative Insertion Force Measurements for Cochlear Implant Surgery.
    Bottcher-Rebmann G; Schell V; Budde L; Zuniga MG; Baier C; Lenarz T; Rau TS
    IEEE Trans Biomed Eng; 2023 May; 70(5):1643-1650. PubMed ID: 36423317
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development and evaluation of the modiolar research array--multi-centre collaborative study in human temporal bones.
    Briggs RJ; Tykocinski M; Lazsig R; Aschendorff A; Lenarz T; Stöver T; Fraysse B; Marx M; Roland JT; Roland PS; Wright CG; Gantz BJ; Patrick JF; Risi F
    Cochlear Implants Int; 2011 Aug; 12(3):129-39. PubMed ID: 21917200
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Preliminary application of robot-assisted electrode insertion in cochlear implantation].
    Jia H; Pan JX; Li Y; Zhang ZH; Tan HY; Wang ZY; Wu H
    Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2020 Oct; 55(10):952-956. PubMed ID: 33036510
    [No Abstract]   [Full Text] [Related]  

  • 10. A Steadier Hand: The First Human Clinical Trial of a Single-Use Robotic-Assisted Surgical Device for Cochlear Implant Electrode Array Insertion.
    Gantz JA; Gantz BJ; Kaufmann CR; Henslee AM; Dunn CC; Hua X; Hansen MR
    Otol Neurotol; 2023 Jan; 44(1):34-39. PubMed ID: 36509435
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Insertion forces and intracochlear trauma in temporal bone specimens implanted with a straight atraumatic electrode array.
    Mirsalehi M; Rau TS; Harbach L; Hügl S; Mohebbi S; Lenarz T; Majdani O
    Eur Arch Otorhinolaryngol; 2017 May; 274(5):2131-2140. PubMed ID: 28238160
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Damage to inner ear structure during cochlear implantation: Correlation between insertion force and radio-histological findings in temporal bone specimens.
    De Seta D; Torres R; Russo FY; Ferrary E; Kazmitcheff G; Heymann D; Amiaud J; Sterkers O; Bernardeschi D; Nguyen Y
    Hear Res; 2017 Feb; 344():90-97. PubMed ID: 27825860
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Force of cochlear implant electrode insertion performed by a robotic insertion tool: comparison of traditional versus Advance Off-Stylet techniques.
    Schurzig D; Webster RJ; Dietrich MS; Labadie RF
    Otol Neurotol; 2010 Oct; 31(8):1207-10. PubMed ID: 20814345
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Preclinical evaluation of a tool for insertion force measurements in cochlear implant surgery.
    Böttcher-Rebmann G; Schell V; Zuniga MG; Salcher R; Lenarz T; Rau TS
    Int J Comput Assist Radiol Surg; 2023 Nov; 18(11):2117-2124. PubMed ID: 37310560
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Atraumatic Insertion of a Cochlear Implant Pre-Curved Electrode Array by a Robot-Automated Alignment with the Coiling Direction of the Scala Tympani.
    Torres R; Hochet B; Daoudi H; Carré F; Mosnier I; Sterkers O; Ferrary E; Nguyen Y
    Audiol Neurootol; 2022; 27(2):148-155. PubMed ID: 34284383
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Uncovering Vulnerable Phases in Cochlear Implant Electrode Array Insertion: Insights from an In Vitro Model.
    Aebischer P; Weder S; Vischer M; Mantokoudis G; Caversaccio M; Wimmer W
    Otol Neurotol; 2024 Apr; 45(4):e271-e280. PubMed ID: 38346807
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hydraulic insertions of cochlear implant electrode arrays into the human cadaver cochlea: preliminary findings.
    Geraldine Zuniga M; Lenarz T; Rau TS
    Eur Arch Otorhinolaryngol; 2022 Jun; 279(6):2827-2835. PubMed ID: 34390390
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of an electrode prototype for atraumatic cochlear implantation in hearing preservation candidates: preliminary results from a temporal bone study.
    Helbig S; Settevendemie C; Mack M; Baumann U; Helbig M; Stöver T
    Otol Neurotol; 2011 Apr; 32(3):419-23. PubMed ID: 21307807
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An In-Vitro Insertion-Force Study of Magnetically Guided Lateral-Wall Cochlear-Implant Electrode Arrays.
    Leon L; Warren FM; Abbott JJ
    Otol Neurotol; 2018 Feb; 39(2):e63-e73. PubMed ID: 29315180
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Factors associated with incomplete insertion of electrodes in cochlear implant surgery: a histopathologic study.
    Lee J; Nadol JB; Eddington DK
    Audiol Neurootol; 2011; 16(2):69-81. PubMed ID: 20571258
    [TBL] [Abstract][Full Text] [Related]  