These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 38996861)

  • 21. Emergency Transcatheter Aortic Valve Implantation for Acute and Early Failure of Sutureless Perceval Aortic Valve.
    Durand E; Tron C; Eltchaninoff H
    Can J Cardiol; 2015 Sep; 31(9):1204.e13-5. PubMed ID: 26095935
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Pure Cusp Tear of Trifecta Bioprosthesis 2 Years after Aortic Valve Replacement.
    Hamamoto M; Kobayashi T; Ozawa M; Yoshimura K
    Ann Thorac Cardiovasc Surg; 2017 Jun; 23(3):157-160. PubMed ID: 27980283
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Determinants of Bioprosthetic Aortic Valve Degeneration.
    Nitsche C; Kammerlander AA; Knechtelsdorfer K; Kraiger JA; Goliasch G; Dona C; Schachner L; Öztürk B; Binder C; Duca F; Aschauer S; Zimpfer D; Bonderman D; Hengstenberg C; Mascherbauer J
    JACC Cardiovasc Imaging; 2020 Feb; 13(2 Pt 1):345-353. PubMed ID: 30878425
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Management of aortic insufficiency with continuous flow left ventricular assist devices: bioprosthetic valve replacement.
    Feldman CM; Silver MA; Sobieski MA; Slaughter MS
    J Heart Lung Transplant; 2006 Dec; 25(12):1410-2. PubMed ID: 17178333
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: technical considerations and results.
    Bapat V; Attia R; Redwood S; Hancock J; Wilson K; Young C; Thomas M
    J Thorac Cardiovasc Surg; 2012 Dec; 144(6):1372-9; discussion 1379-80. PubMed ID: 23140962
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Early Structural Valve Deterioration of Trifecta Aortic Bioprosthesis:Report of a Case].
    Tanaka K; Suzuki T; Kobayashi J; Yasukawa T
    Kyobu Geka; 2023 Oct; 76(11):949-952. PubMed ID: 38056954
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A comparison of valve-in-valve transcatheter aortic valve replacement in failed stentless versus stented surgical bioprosthetic aortic valves.
    Choi CH; Cheng V; Malaver D; Kon N; Kincaid EH; Gandhi SK; Applegate RJ; Zhao DXM
    Catheter Cardiovasc Interv; 2019 May; 93(6):1106-1115. PubMed ID: 30588736
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.
    Dvir D; Webb JG; Bleiziffer S; Pasic M; Waksman R; Kodali S; Barbanti M; Latib A; Schaefer U; Rodés-Cabau J; Treede H; Piazza N; Hildick-Smith D; Himbert D; Walther T; Hengstenberg C; Nissen H; Bekeredjian R; Presbitero P; Ferrari E; Segev A; de Weger A; Windecker S; Moat NE; Napodano M; Wilbring M; Cerillo AG; Brecker S; Tchetche D; Lefèvre T; De Marco F; Fiorina C; Petronio AS; Teles RC; Testa L; Laborde JC; Leon MB; Kornowski R;
    JAMA; 2014 Jul; 312(2):162-70. PubMed ID: 25005653
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Reoperation for early failure of a freestyle bioprosthesis using a full root technique.
    Kitamura A; Handa N; Shomura Y; Wakiyama H; Shinka M; Fujiwara H; Nasu M; Tanabe K; Tani T; Morioka S; Okada Y
    J Heart Valve Dis; 2007 May; 16(3):275-7. PubMed ID: 17578047
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Durability of bioprosthetic aortic valves in patients under the age of 60 years - rationale and design of the international INDURE registry.
    Meuris B; Borger MA; Bourguignon T; Siepe M; Grabenwöger M; Laufer G; Binder K; Polvani G; Stefano P; Coscioni E; van Leeuwen W; Demers P; Dagenais F; Canovas S; Theron A; Langanay T; Roussel JC; Wendler O; Mariscalco G; Pessotto R; Botta B; Bramlage P; de Paulis R
    J Cardiothorac Surg; 2020 May; 15(1):119. PubMed ID: 32460798
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Valve-in-valve transcatheter aortic valve implantation overcoming hostile anatomy: Evolut R for the treatment of Mitroflow bioprosthesis dysfunction.
    Ruparelia N; Colombo A; Latib A
    Cardiovasc Interv Ther; 2016 Oct; 31(4):292-5. PubMed ID: 26371364
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Successful transfemoral Edwards SAPIEN 3 valve in valve implantation in a patient with a degenerated aortic bioprosthesis associated with severe paravalvular aortic regurgitation.
    Bijuklic K; Hansen L; Witt J; Schofer J
    Clin Res Cardiol; 2015 Jan; 104(1):92-3. PubMed ID: 25227426
    [No Abstract]   [Full Text] [Related]  

  • 33. Transcatheter aortic valve implantation for severe regurgitation in native and degenerated bioprosthetic aortic valves.
    Sarkar K; Sardella G; Romeo F; De Benedictis M; Tarsia G; Iadanza A; Sharma SK; Barbanti M; Tamburino C; Ussia GP
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):864-70. PubMed ID: 22997004
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Transcatheter aortic valve implantation in degenerative sutureless perceval aortic bioprosthesis.
    Landes U; Sagie A; Kornowski R
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):1000-1004. PubMed ID: 27696650
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Role of Diastology in Transcatheter Aortic Valve Implantation.
    Sivasubramonian S; Gopalakrishnan A; Sasidharan B; Valaparambil A
    J Invasive Cardiol; 2018 Mar; 30(3):E23-E24. PubMed ID: 29493515
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Outcomes of bovine versus porcine surgical aortic valve replacement.
    Yousef S; Dai Y; Aranda-Michel E; Brown JA; Serna-Gallegos D; Kaczorowski D; Bonatti J; Yoon P; Chu D; Sultan I
    J Card Surg; 2022 Dec; 37(12):4555-4561. PubMed ID: 36335592
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Novel use of a percutaneous aortic valve in stentless bioprosthetic CryoLife-O'Brien valve dysfunction.
    Layland J; Bell B; Latona J; Mullany D; Manaharan G; Thompson B; Aroney C; Walters D
    J Heart Valve Dis; 2010 Mar; 19(2):263-4. PubMed ID: 20369516
    [No Abstract]   [Full Text] [Related]  

  • 38. Successful percutaneous paravalvular leak closure followed by transfemoral aortic lotus valve-in-valve implantation in a degenerated surgical bioprosthesis.
    Nerla R; Cremonesi A; Castriota F
    Catheter Cardiovasc Interv; 2018 Jan; 91(1):169-174. PubMed ID: 27143596
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Unusual cause of severe transvalvular eccentric jet AR: early structure valve deterioration of Trifecta valves by flail leaflet undergoing valve-in-valve transcatheter aortic valve replacement.
    Chatlaong T; Kosum P; Tumkosit M; Limjareon T
    BMJ Case Rep; 2024 Feb; 17(2):. PubMed ID: 38395470
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Intracardiac echo imaging of a transfemoral aortic Edwards SAPIEN valve implantation in a degenerated bioprosthesis (valve-in-valve).
    Kefer J; Astarci P; Renkin J
    J Invasive Cardiol; 2010 Jul; 22(7):341-2. PubMed ID: 20603509
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.