These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 39001136)

  • 1. A 3 MHz Low-Error Adaptive Howland Current Source for High-Frequency Bioimpedance Applications.
    Nwokoye II; Triantis IF
    Sensors (Basel); 2024 Jul; 24(13):. PubMed ID: 39001136
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The differential Howland current source with high signal to noise ratio for bioimpedance measurement system.
    Liu J; Qiao X; Wang M; Zhang W; Li G; Lin L
    Rev Sci Instrum; 2014 May; 85(5):055111. PubMed ID: 24880419
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bandwidth and Common Mode Optimization for Current and Voltage Sources in Bioimpedance Spectroscopy.
    Menden T; Matuszczyk J; Leonhardt S; Walter M
    J Electr Bioimpedance; 2021 Jan; 12(1):135-146. PubMed ID: 35069949
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biocompatible, high precision, wideband, improved Howland current source with lead-lag compensation.
    Tucker AS; Fox RM; Sadleir RJ
    IEEE Trans Biomed Circuits Syst; 2013 Feb; 7(1):63-70. PubMed ID: 23853280
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of a new integrated current source with the modified Howland circuit for EIT applications.
    Hong H; Rahal M; Demosthenous A; Bayford RH
    Physiol Meas; 2009 Oct; 30(10):999-1007. PubMed ID: 19706961
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design of Howland Current Sources Using Differential Evolution Optimization.
    Morcelles KF; Negri LH; Bertemes-Filho P
    J Electr Bioimpedance; 2020 Jan; 11(1):96-100. PubMed ID: 33584909
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Howland current source for high impedance load applications.
    Morcelles KF; Sirtoli VG; Bertemes-Filho P; Vincence VC
    Rev Sci Instrum; 2017 Nov; 88(11):114705. PubMed ID: 29195397
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Research on Constant-current Characteristics of Howland Current Source Used in Bioelectrical Impedance Detection].
    Lin X; Zhao W; Liu X; Li L
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2015 Apr; 32(2):290-4. PubMed ID: 26211242
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mirrored enhanced Howland current source with feedback control.
    Grando Sirtoli V; Coelho Vincence V; Bertemes-Filho P
    Rev Sci Instrum; 2019 Feb; 90(2):024702. PubMed ID: 30831761
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Balanced Adjustable Mirrored Current Source with Common Mode Feedback and Output Measurement for Bioimpedance Applications.
    Klum M; Schmidt M; Klaproth J; Pielmus AG; Tigges T; Orglmeister R
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():1278-1281. PubMed ID: 31946125
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of modified Howland circuits as current generators with current mirror type circuits.
    Bertemes-Filho P; Brown BH; Wilson AJ
    Physiol Meas; 2000 Feb; 21(1):1-6. PubMed ID: 10719993
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Adaptive frequency distribution for electrical bioimpedance spectroscopy measurements.
    Seoane F; Ferreira J; Buendia R; Lindecrantz K
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():562-5. PubMed ID: 23365954
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design of current source for multi-frequency simultaneous electrical impedance tomography.
    Han B; Xu Y; Dong F
    Rev Sci Instrum; 2017 Sep; 88(9):094709. PubMed ID: 28964244
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A Sinusoidal Current Driver With an Extended Frequency Range and Multifrequency Operation for Bioimpedance Applications.
    Langlois PJ; Neshatvar N; Demosthenous A
    IEEE Trans Biomed Circuits Syst; 2015 Jun; 9(3):401-11. PubMed ID: 25148669
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A high accuracy broadband measurement system for time resolved complex bioimpedance measurements.
    Kaufmann S; Malhotra A; Ardelt G; Ryschka M
    Physiol Meas; 2014 Jun; 35(6):1163-80. PubMed ID: 24845882
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analog Integrated Current Drivers for Bioimpedance Applications: A Review.
    Neshatvar N; Langlois P; Bayford R; Demosthenous A
    Sensors (Basel); 2019 Feb; 19(4):. PubMed ID: 30781772
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bioimpedance analysis: a guide to simple design and implementation.
    Aroom KR; Harting MT; Cox CS; Radharkrishnan RS; Smith C; Gill BS
    J Surg Res; 2009 May; 153(1):23-30. PubMed ID: 18805550
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bioimpedance Assessment of Oral Squamous Cell Carcinoma with Clinicopathological Correlation.
    Sarode GS; Sarode SC; Kulkarni M; Karmarkar S; Patll S; Auciustine D
    J Contemp Dent Pract; 2015 Sep; 16(9):715-22. PubMed ID: 26522596
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Note: Temperature effects in the modified Howland current source for electrical bioimpedance spectroscopy.
    Fernandez Santos S; Bertemes-Filho P
    Rev Sci Instrum; 2017 Jul; 88(7):076103. PubMed ID: 28764509
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Current source design for electrical impedance tomography.
    Ross AS; Saulnier GJ; Newell JC; Isaacson D
    Physiol Meas; 2003 May; 24(2):509-16. PubMed ID: 12812434
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.