These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 39002745)

  • 1. Portable loop-mediated isothermal amplification device with spectrometric detection for rapid pathogen identification.
    Pan CY; Kijamnajsuk P; Chen JJ
    Anal Biochem; 2024 Nov; 694():115615. PubMed ID: 39002745
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Loop-mediated isothermal amplification (LAMP) for the rapid and sensitive detection of Salmonella Typhimurium from pork.
    Techathuvanan C; Draughon FA; D'Souza DH
    J Food Sci; 2010 Apr; 75(3):M165-72. PubMed ID: 20492306
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An integrated rotary microfluidic system with DNA extraction, loop-mediated isothermal amplification, and lateral flow strip based detection for point-of-care pathogen diagnostics.
    Park BH; Oh SJ; Jung JH; Choi G; Seo JH; Kim DH; Lee EY; Seo TS
    Biosens Bioelectron; 2017 May; 91():334-340. PubMed ID: 28043075
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a quantitative fluorescence single primer isothermal amplification-based method for the detection of Salmonella.
    Wang J; Li R; Hu L; Sun X; Wang J; Li J
    Int J Food Microbiol; 2016 Feb; 219():22-7. PubMed ID: 26704066
    [TBL] [Abstract][Full Text] [Related]  

  • 5. One-tube detection of
    Gong J; Jiang Y; Zhang D; Li T; Fu L; Dou X
    Microbiol Spectr; 2024 Oct; 12(10):e0127124. PubMed ID: 39189759
    [TBL] [Abstract][Full Text] [Related]  

  • 6. iso-μmGene: an isothermal amplification-based portable microfluidic system for simple, reliable and flexibly multiplexed genetic identification and quantification.
    Zhong R; Liu S; Zhang G; Wang M; Sun Y
    Analyst; 2020 Jul; 145(13):4627-4636. PubMed ID: 32458852
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A lab-on-chip device for the sample-in-result-out detection of viable Salmonella using loop-mediated isothermal amplification and real-time turbidity monitoring.
    Wang S; Liu N; Zheng L; Cai G; Lin J
    Lab Chip; 2020 Jun; 20(13):2296-2305. PubMed ID: 32484172
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Propidium monoazide real-time loop-mediated isothermal amplification for specific visualization of viable Salmonella in food.
    Fang J; Wu Y; Qu D; Ma B; Yu X; Zhang M; Han J
    Lett Appl Microbiol; 2018 Jul; 67(1):79-88. PubMed ID: 29665023
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rapid, sensitive, and quantitative detection of pathogenic DNA at the point of care through microfluidic electrochemical quantitative loop-mediated isothermal amplification.
    Hsieh K; Patterson AS; Ferguson BS; Plaxco KW; Soh HT
    Angew Chem Int Ed Engl; 2012 May; 51(20):4896-900. PubMed ID: 22488842
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of a visual detection method for Salmonella based on loop-mediated isothermal amplification using pyrophosphatase.
    Liu W; Zhang S; Chen C; Jin J; Liu H; Bian Z; Qi W; Xie Y; Zhang H
    FEMS Microbiol Lett; 2023 Jan; 370():. PubMed ID: 37291705
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Salmonella Typhimurium Sensing Strategy Based on the Loop-Mediated Isothermal Amplification Using Retroreflective Janus Particle as a Nonspectroscopic Signaling Probe.
    Chun HJ; Kim S; Han YD; Kim KR; Kim JH; Yoon H; Yoon HC
    ACS Sens; 2018 Nov; 3(11):2261-2268. PubMed ID: 30350587
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rapid detection of Salmonella in food and feed by coupling loop-mediated isothermal amplification with bioluminescent assay in real-time.
    Yang Q; Domesle KJ; Wang F; Ge B
    BMC Microbiol; 2016 Jun; 16(1):112. PubMed ID: 27316515
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A fully disposable and integrated paper-based device for nucleic acid extraction, amplification and detection.
    Tang R; Yang H; Gong Y; You M; Liu Z; Choi JR; Wen T; Qu Z; Mei Q; Xu F
    Lab Chip; 2017 Mar; 17(7):1270-1279. PubMed ID: 28271104
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Semi-quantitative visual detection of loop mediated isothermal amplification (LAMP)-generated DNA by distance-based measurement on a paper device.
    Hongwarittorrn I; Chaichanawongsaroj N; Laiwattanapaisal W
    Talanta; 2017 Dec; 175():135-142. PubMed ID: 28841970
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a multiplex loop-mediated isothermal amplification method for the simultaneous detection of Salmonella spp. and Vibrio parahaemolyticus.
    Liu N; Zou D; Dong D; Yang Z; Ao D; Liu W; Huang L
    Sci Rep; 2017 Mar; 7():45601. PubMed ID: 28349967
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Paper-Based Device for Performing Loop-Mediated Isothermal Amplification with Real-Time Simultaneous Detection of Multiple DNA Targets.
    Seok Y; Joung HA; Byun JY; Jeon HS; Shin SJ; Kim S; Shin YB; Han HS; Kim MG
    Theranostics; 2017; 7(8):2220-2230. PubMed ID: 28740546
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pathogenic Bacteria Detection Using RNA-Based Loop-Mediated Isothermal-Amplification-Assisted Nucleic Acid Amplification via Droplet Microfluidics.
    Azizi M; Zaferani M; Cheong SH; Abbaspourrad A
    ACS Sens; 2019 Apr; 4(4):841-848. PubMed ID: 30908029
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A newly developed paper embedded microchip based on LAMP for rapid multiple detections of foodborne pathogens.
    Zhang M; Liu J; Shen Z; Liu Y; Song Y; Liang Y; Li Z; Nie L; Fang Y; Zhao Y
    BMC Microbiol; 2021 Jun; 21(1):197. PubMed ID: 34182947
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Loop-mediated isothermal amplification for the rapid detection of Salmonella.
    Hara-Kudo Y; Yoshino M; Kojima T; Ikedo M
    FEMS Microbiol Lett; 2005 Dec; 253(1):155-61. PubMed ID: 16242860
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fully automated and colorimetric foodborne pathogen detection on an integrated centrifugal microfluidic device.
    Oh SJ; Park BH; Choi G; Seo JH; Jung JH; Choi JS; Kim do H; Seo TS
    Lab Chip; 2016 May; 16(10):1917-26. PubMed ID: 27112702
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.