These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 39003592)

  • 1. A novel method for highly linear gradient coil design based on stream function.
    Zhou Y; Liu Z; Zhang Q; Du H; Qi F; Wang C; Luo P; Yuan K; Liu Q; Huang X; Qiu B
    Med Phys; 2024 Oct; 51(10):7180-7190. PubMed ID: 39003592
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multi-target field control for matrix gradient coils.
    He H; Wei S; Wang H; Yang W
    MAGMA; 2024 Apr; 37(2):185-198. PubMed ID: 38386153
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Spiral Gradient Coil Design for Use in Cylindrical MRI Systems.
    Wang Y; Xin X; Liu F; Crozier S
    IEEE Trans Biomed Eng; 2018 Apr; 65(4):911-920. PubMed ID: 28715323
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A spiral, bi-planar gradient coil design for open magnetic resonance imaging.
    Zhang P; Shi Y; Wang W; Wang Y
    Technol Health Care; 2018; 26(1):119-132. PubMed ID: 29254119
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Stream function optimization for gradient coil design.
    Tomasi D
    Magn Reson Med; 2001 Mar; 45(3):505-12. PubMed ID: 11241710
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Minimizing electric fields and increasing peripheral nerve stimulation thresholds using a body gradient array coil.
    Babaloo R; Atalar E
    Magn Reson Med; 2024 Sep; 92(3):1290-1305. PubMed ID: 38624032
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 3-D gradient coil design--initial theoretical framework.
    While PT; Forbes LK; Crozier S
    IEEE Trans Biomed Eng; 2009 Apr; 56(4):1169-83. PubMed ID: 19174330
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A finite difference method for the design of gradient coils in MRI--an initial framework.
    Zhu M; Xia L; Liu F; Zhu J; Kang L; Crozier S
    IEEE Trans Biomed Eng; 2012 Sep; 59(9):2412-21. PubMed ID: 22353392
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Homogeneous B0 coil design method for open-access ultra-low field magnetic resonance imaging: A simulation study.
    Karasawa T; Saikawa J; Munaka T; Kobayashi T
    Magn Reson Imaging; 2024 Oct; 112():128-135. PubMed ID: 38986889
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The coil array method for creating a dynamic imaging volume.
    Smith E; Freschi F; Repetto M; Crozier S
    Magn Reson Med; 2017 Aug; 78(2):784-793. PubMed ID: 27605037
    [TBL] [Abstract][Full Text] [Related]  

  • 11. True energy-minimal and finite-size biplanar gradient coil design for MRI.
    Liu H; Truwit CL
    IEEE Trans Med Imaging; 1998 Oct; 17(5):826-30. PubMed ID: 9874308
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Numerical Design of High-Efficiency Whole-Body Gradient Coils With a Hybrid Cylindrical-Planar Structure.
    Chaoqun Niu ; Qiuliang Wang ; Yang Hu ; Yaohui Wang ; Fangfang Tang ; Feng Liu ; Crozier S
    IEEE Trans Biomed Eng; 2019 Jun; 66(6):1628-1636. PubMed ID: 30346278
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance evaluation of matrix gradient coils.
    Jia F; Schultz G; Testud F; Welz AM; Weber H; Littin S; Yu H; Hennig J; Zaitsev M
    MAGMA; 2016 Feb; 29(1):59-73. PubMed ID: 26667966
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A theoretical framework of gradient coil designed to mitigate eddy currents for a permanent magnet MRI system.
    Zhang P; Wang W; Shi Y
    Technol Health Care; 2022; 30(S1):315-328. PubMed ID: 35124608
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Studies on the performance of circular and elliptical Z-gradient coils using a simulated annealing algorithm.
    Du YP; Parker DL
    Magn Reson Imaging; 1997; 15(2):255-62. PubMed ID: 9106154
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Planar gradient coil design by scaling the spatial frequencies of minimum-inductance current density.
    Lee SY; Park BS; Yi JH; Yi W
    Magn Reson Med; 1997 Nov; 38(5):858-61. PubMed ID: 9358463
    [TBL] [Abstract][Full Text] [Related]  

  • 17. 3D-gradient coil structures for MRI designed using fuzzy membership functions.
    Sánchez H; Liu F; Trakic A; Weber E; Crozier S
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():2042-5. PubMed ID: 18002387
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A volumetric finite-difference method for the design of three-dimensional, arbitrary-structured MRI gradient coil.
    Kang L; Xia L; Wang Q; Wang Y; Tang F; Liu F
    Rev Sci Instrum; 2021 Mar; 92(3):034712. PubMed ID: 33820029
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A bi-planar coil system for nulling background magnetic fields in scalp mounted magnetoencephalography.
    Holmes N; Leggett J; Boto E; Roberts G; Hill RM; Tierney TM; Shah V; Barnes GR; Brookes MJ; Bowtell R
    Neuroimage; 2018 Nov; 181():760-774. PubMed ID: 30031934
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Designing gradient coils with reduced hot spot temperatures.
    While PT; Forbes LK; Crozier S
    J Magn Reson; 2010 Mar; 203(1):91-9. PubMed ID: 20036170
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.