BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 3900670)

  • 1. The influence of phantom size on output, peak scatter factor, and percentage depth dose in large-field photon irradiation.
    Podgorsak EB; Pla C; Evans MD; Pla M
    Med Phys; 1985; 12(5):639-45. PubMed ID: 3900670
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wedge factor constituents of high-energy photon beams: head and phantom scatter dose components.
    Heukelom S; Lanson JH; Mijnheer BJ
    Radiother Oncol; 1994 Jul; 32(1):73-83. PubMed ID: 7938681
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Calculation of dose in homogeneous phantoms for partially attenuated photon beams.
    el-Khatib E; Podgorsak EB; Pla C
    Med Phys; 1988; 15(2):145-50. PubMed ID: 3386582
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Verification of total body photon irradiation dosimetry techniques.
    Kirby TH; Hanson WF; Cates DA
    Med Phys; 1988; 15(3):364-9. PubMed ID: 3043155
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Is there a need for a revised table of equivalent square fields for the determination of phantom scatter correction factors?
    Venselaar JL; Heukelom S; Jager HN; Mijnheer BJ; van Gasteren JJ; van Kleffens HJ; van der Laarse R; Westermann CF
    Phys Med Biol; 1997 Dec; 42(12):2369-81. PubMed ID: 9434294
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of correction factors for a 2D diode array device in MV photon beams.
    Zhou X; Both S; Zhu TC
    Med Phys; 2009 Feb; 36(2):523-9. PubMed ID: 19291991
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Monte Carlo study on internal wedges using BEAM.
    van der Zee W; Welleweerd J
    Med Phys; 2002 May; 29(5):876-85. PubMed ID: 12033584
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Surface dosimetry for oblique tangential photon beams: a Monte Carlo simulation study.
    Chow JC; Grigorov GN
    Med Phys; 2008 Jan; 35(1):70-6. PubMed ID: 18293563
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Differences in wedge factor determination in air using a PMMA mini-phantom or a brass build-up cap.
    Heukelom S; Lanson JH; Mijnheer BJ
    Med Phys; 1997 Dec; 24(12):1986-91. PubMed ID: 9434981
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dose-rate distribution under partially shielded beams.
    Malicki J; Lobodziec W; Slosarek K
    Strahlenther Onkol; 1990 Nov; 166(11):733-7. PubMed ID: 2260011
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The dosimetry of fixed, single source hemibody and total body irradiators.
    Glasgow GP
    Med Phys; 1982; 9(3):311-23. PubMed ID: 6810077
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis of various beamlet sizes for IMRT with 6 MV photons.
    Sohn JW; Dempsey JF; Suh TS; Low DA
    Med Phys; 2003 Sep; 30(9):2432-9. PubMed ID: 14528965
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of immobilization beds on the dose in the entrance and exit dose region for Co-60, 4, 6 and 15 MV photons.
    Bilge H; Yondem S; Kucucuk H; Cakir A; Meral R
    J BUON; 2008; 13(3):385-90. PubMed ID: 18979554
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Beam configuration and physical parameters of clinical high energy photon beam for total body irradiation (TBI).
    Ravichandran R; Binukumar JP; Davis CA; Sivakumar SS; Krishnamurthy K; Mandhari ZA; Rajan B
    Phys Med; 2011 Jul; 27(3):163-8. PubMed ID: 21074467
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Physical approach to depth dose distributions in a water phantom irradiated by a teleisotope photon beam.
    Ahuja SD; Stroup SL; Bolin MG; Gibbs SJ
    Med Phys; 1980; 7(2):120-6. PubMed ID: 7382915
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The determination of phantom and collimator scatter components of the output of megavoltage photon beams: measurement of the collimator scatter part with a beam-coaxial narrow cylindrical phantom.
    van Gasteren JJ; Heukelom S; van Kleffens HJ; van der Laarse R; Venselaar JL; Westermann CF
    Radiother Oncol; 1991 Apr; 20(4):250-7. PubMed ID: 1906190
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A simple dose calculation method for total body photon irradiation.
    Curran WJ; Galvin JM; D'Angio GJ
    Int J Radiat Oncol Biol Phys; 1989 Jul; 17(1):219-24. PubMed ID: 2663798
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An analytical formalism to calculate phantom scatter factors for flattening filter free (FFF) mode photon beams.
    Chung H; Prado KL; Yi BY
    Phys Med Biol; 2014 Feb; 59(4):951-60. PubMed ID: 24503449
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of optically stimulated luminescence dosimeter for exit dose
    Ponmalar R; Manickam R; Saminathan S; Ganesh KM; Raman A; Godson HF
    J Cancer Res Ther; 2018; 14(6):1341-1349. PubMed ID: 30488854
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
    Ding GX; Duggan DM; Coffey CW
    Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.