These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 39017668)

  • 1. Whole Blood Aggregometry in Mice.
    Branfield S; Somani Y; Washington AV; Manfredi B
    Curr Protoc; 2024 Jul; 4(7):e1095. PubMed ID: 39017668
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of multiple electrode aggregometry with lumi-aggregometry for the diagnosis of patients with mild bleeding disorders.
    Al Ghaithi R; Drake S; Watson SP; Morgan NV; Harrison P
    J Thromb Haemost; 2017 Oct; 15(10):2045-2052. PubMed ID: 28762630
    [TBL] [Abstract][Full Text] [Related]  

  • 3. How to perform aggregometry and lumi-aggregometry in mouse platelets.
    Hughes CE
    Platelets; 2018 Nov; 29(7):638-643. PubMed ID: 29863944
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Current and emerging approaches for evaluating platelet disorders.
    Podda G; Femia EA; Cattaneo M
    Int J Lab Hematol; 2016 May; 38 Suppl 1():50-8. PubMed ID: 27426860
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of aspirin response by Multiplate whole blood aggregometry and light transmission aggregometry.
    Pedersen SB; Grove EL; Nielsen HL; Mortensen J; Kristensen SD; Hvas AM
    Platelets; 2009 Sep; 20(6):415-20. PubMed ID: 19658002
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of Platelet Aggregate Formation in Blood Samples on Light Transmission Aggregometry Results.
    Sugawara E; Shimizu M; Yamamoto M; Kudo Y; Tanaka F; Johkura K
    J Stroke Cerebrovasc Dis; 2019 Apr; 28(4):1001-1006. PubMed ID: 30630755
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Flow-chamber device (T-TAS) to diagnose patients suspected of platelet function defects.
    Lecchi A; La Marca S; Padovan L; Boscarino M; Peyvandi F; Tripodi A
    Blood Transfus; 2024 Jan; 22(1):55-64. PubMed ID: 36795343
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a whole blood remote platelet function test for the diagnosis of mild bleeding disorders.
    Dovlatova N; Lordkipanidzé M; Lowe GC; Dawood B; May J; Heptinstall S; Watson SP; Fox SC;
    J Thromb Haemost; 2014 May; 12(5):660-5. PubMed ID: 24618131
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An assessment of cardiopulmonary bypass-induced changes in platelet function using whole blood and classical light transmission aggregometry: the results of a pilot study.
    Velik-Salchner C; Maier S; Innerhofer P; Kolbitsch C; Streif W; Mittermayr M; Praxmarer M; Fries D
    Anesth Analg; 2009 Jun; 108(6):1747-54. PubMed ID: 19448196
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Platelet Function Analyzed by Light Transmission Aggregometry.
    Hvas AM; Favaloro EJ
    Methods Mol Biol; 2017; 1646():321-331. PubMed ID: 28804839
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of light transmission aggregometry and multiple electrode aggregometry for the evaluation of patients with mucocutaneous bleeding.
    Sun P; McMillan-Ward E; Mian R; Israels SJ
    Int J Lab Hematol; 2019 Feb; 41(1):133-140. PubMed ID: 30358923
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of ADP-induced platelet aggregation with light transmission aggregometry and multiple electrode platelet aggregometry before and after clopidogrel treatment.
    Sibbing D; Braun S; Jawansky S; Vogt W; Mehilli J; Schömig A; Kastrati A; von Beckerath N
    Thromb Haemost; 2008 Jan; 99(1):121-6. PubMed ID: 18217143
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the platelet count drop method for assessment of platelet function in comparison with "gold standard" light transmission aggregometry.
    Lordkipanidzé M; Pharand C; Schampaert E; Palisaitis DA; Diodati JG
    Thromb Res; 2009 Sep; 124(4):418-22. PubMed ID: 19250657
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison between urinary 11-dehydrothromboxane B2 detection and platelet Light Transmission Aggregometry (LTA) assays for evaluating aspirin response in elderly patients with coronary artery disease.
    Liu T; Zhang J; Chen X; Feng X; Fu SW; McCaffrey TA; Liu M
    Gene; 2015 Oct; 571(1):23-7. PubMed ID: 26095809
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The risk of false results in the assessment of platelet function in the absence of antiplatelet medication: comparison of the PFA-100, multiplate electrical impedance aggregometry and verify now assays.
    Can MM; Tanboğa IH; Türkyilmaz E; Karabay CY; Akgun T; Koca F; Tokgoz HC; Keles N; Ozkan A; Bezgin T; Ozveren O; Sonmez K; Sağlam M; Ozdemir N; Kaymaz C
    Thromb Res; 2010 Apr; 125(4):e132-7. PubMed ID: 19954823
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pneumatic tube system transport does not alter platelet function in optical and whole blood aggregometry, prothrombin time, activated partial thromboplastin time, platelet count and fibrinogen in patients on anti-platelet drug therapy.
    Enko D; Mangge H; Münch A; Niedrist T; Mahla E; Metzler H; Prüller F
    Biochem Med (Zagreb); 2017 Feb; 27(1):217-224. PubMed ID: 28392742
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of conventional aggregometry with VASP for monitoring P2Y12-specific platelet inhibition.
    Aradi D; Magyarlaki T; Tokés-Füzesi M; Rideg O; Vorobcsuk A; Komócsi A
    Platelets; 2010; 21(7):563-70. PubMed ID: 20642320
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The study of platelet aggregation using a microtiter plate reader ‒ methodological considerations.
    Boncler M; Golański J
    Pharmacol Rep; 2024 Apr; 76(2):328-337. PubMed ID: 38438661
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Centrifugation speed affects light transmission aggregometry.
    Merolla M; Nardi MA; Berger JS
    Int J Lab Hematol; 2012 Feb; 34(1):81-5. PubMed ID: 21794095
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Platelet Function Tests in Bleeding Disorders.
    Lassila R
    Semin Thromb Hemost; 2016 Apr; 42(3):185-90. PubMed ID: 26886396
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.