These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
143 related articles for article (PubMed ID: 39034856)
21. Microfluidic device (ExoChip) for on-chip isolation, quantification and characterization of circulating exosomes. Kanwar SS; Dunlay CJ; Simeone DM; Nagrath S Lab Chip; 2014 Jun; 14(11):1891-900. PubMed ID: 24722878 [TBL] [Abstract][Full Text] [Related]
22. Nickel-Doped Microfluidic Chip for Rapid and Efficient Immunomagnetic Separation and Detection of Breast Cancer Cell-Derived Exosomes. Fang H; Liu M; Jiang W Appl Biochem Biotechnol; 2023 May; 195(5):3109-3121. PubMed ID: 36542270 [TBL] [Abstract][Full Text] [Related]
23. Field-Free Isolation of Exosomes from Extracellular Vesicles by Microfluidic Viscoelastic Flows. Liu C; Guo J; Tian F; Yang N; Yan F; Ding Y; Wei J; Hu G; Nie G; Sun J ACS Nano; 2017 Jul; 11(7):6968-6976. PubMed ID: 28679045 [TBL] [Abstract][Full Text] [Related]
24. Exosome Isolation by Ultracentrifugation and Precipitation and Techniques for Downstream Analyses. Coughlan C; Bruce KD; Burgy O; Boyd TD; Michel CR; Garcia-Perez JE; Adame V; Anton P; Bettcher BM; Chial HJ; Königshoff M; Hsieh EWY; Graner M; Potter H Curr Protoc Cell Biol; 2020 Sep; 88(1):e110. PubMed ID: 32633898 [TBL] [Abstract][Full Text] [Related]
25. Microfluidic affinity separation chip for selective capture and release of label-free ovarian cancer exosomes. Hisey CL; Dorayappan KDP; Cohn DE; Selvendiran K; Hansford DJ Lab Chip; 2018 Oct; 18(20):3144-3153. PubMed ID: 30191215 [TBL] [Abstract][Full Text] [Related]
26. Isolation of Extracellular Vesicles from Cell Culture and Blood Through Nano-Targeted DLD Microfluidic Device. Gaillard M; Sarrut-Rio N; Pudda C; Boizot F; Roupioz Y; Thuaire A Methods Mol Biol; 2024; 2804():77-89. PubMed ID: 38753141 [TBL] [Abstract][Full Text] [Related]
27. The Yin and Yang of exosome isolation methods: conventional practice, microfluidics, and commercial kits. Shirejini SZ; Inci F Biotechnol Adv; 2022; 54():107814. PubMed ID: 34389465 [TBL] [Abstract][Full Text] [Related]
28. Ultrasensitive microfluidic analysis of circulating exosomes using a nanostructured graphene oxide/polydopamine coating. Zhang P; He M; Zeng Y Lab Chip; 2016 Aug; 16(16):3033-42. PubMed ID: 27045543 [TBL] [Abstract][Full Text] [Related]
29. Label-free ferrohydrodynamic separation of exosome-like nanoparticles. Liu Y; Zhao W; Cheng R; Logun M; Zayas-Viera MDM; Karumbaiah L; Mao L Lab Chip; 2020 Aug; 20(17):3187-3201. PubMed ID: 32844860 [TBL] [Abstract][Full Text] [Related]
30. A microfluidic ExoSearch chip for multiplexed exosome detection towards blood-based ovarian cancer diagnosis. Zhao Z; Yang Y; Zeng Y; He M Lab Chip; 2016 Feb; 16(3):489-96. PubMed ID: 26645590 [TBL] [Abstract][Full Text] [Related]
31. Toward low-voltage dielectrophoresis-based microfluidic systems: A review. Ramirez-Murillo CJ; de Los Santos-Ramirez JM; Perez-Gonzalez VH Electrophoresis; 2021 Mar; 42(5):565-587. PubMed ID: 33166414 [TBL] [Abstract][Full Text] [Related]
32. Design of pressure-driven microfluidic networks using electric circuit analogy. Oh KW; Lee K; Ahn B; Furlani EP Lab Chip; 2012 Feb; 12(3):515-45. PubMed ID: 22179505 [TBL] [Abstract][Full Text] [Related]
33. Deterministic Sorting of Submicrometer Particles and Extracellular Vesicles Using a Combined Electric and Acoustic Field. Tayebi M; Yang D; Collins DJ; Ai Y Nano Lett; 2021 Aug; 21(16):6835-6842. PubMed ID: 34355908 [TBL] [Abstract][Full Text] [Related]
34. Towards Microfluidic-Based Exosome Isolation and Detection for Tumor Therapy. Wang J; Ma P; Kim DH; Liu BF; Demirci U Nano Today; 2021 Apr; 37():. PubMed ID: 33777166 [TBL] [Abstract][Full Text] [Related]
35. Clinical application of a microfluidic chip for immunocapture and quantification of circulating exosomes to assist breast cancer diagnosis and molecular classification. Fang S; Tian H; Li X; Jin D; Li X; Kong J; Yang C; Yang X; Lu Y; Luo Y; Lin B; Niu W; Liu T PLoS One; 2017; 12(4):e0175050. PubMed ID: 28369094 [TBL] [Abstract][Full Text] [Related]
36. An immuno-magnetophoresis-based microfluidic chip to isolate and detect HER2-Positive cancer-derived exosomes via multiple separation. Mun B; Kim R; Jeong H; Kang B; Kim J; Son HY; Lim J; Rho HW; Lim EK; Haam S Biosens Bioelectron; 2023 Nov; 239():115592. PubMed ID: 37603987 [TBL] [Abstract][Full Text] [Related]
39. Dean-Flow-Coupled Elasto-Inertial Focusing Accelerates Exosome Purification to Facilitate Single Vesicle Profiling. Bai JJ; Zhang X; Wei X; Wang Y; Du C; Wang ZJ; Chen ML; Wang JH Anal Chem; 2023 Jan; 95(4):2523-2531. PubMed ID: 36657481 [TBL] [Abstract][Full Text] [Related]
40. Integrated immunoisolation and protein analysis of circulating exosomes using microfluidic technology. He M; Crow J; Roth M; Zeng Y; Godwin AK Lab Chip; 2014 Oct; 14(19):3773-80. PubMed ID: 25099143 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]