These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
114 related articles for article (PubMed ID: 3905628)
1. Sodium hypochlorite as a tissue solubilizing agent compatible with liquid scintillation counting. Puchalski RF; Jasper DK Int J Appl Radiat Isot; 1985 Jul; 36(7):543-6. PubMed ID: 3905628 [TBL] [Abstract][Full Text] [Related]
2. Decoloration and solubilization of plant tissue prior to determination of 3H, 14C, and 35S by liquid scintillation. Smith IK; Lang AL Anal Biochem; 1987 Aug; 164(2):531-6. PubMed ID: 3674398 [TBL] [Abstract][Full Text] [Related]
3. Scintillation counting of 14C-labeled soluble and insoluble compounds in plant tissue. Sun D; Wimmers LE; Turgeon R Anal Biochem; 1988 Mar; 169(2):424-7. PubMed ID: 3382014 [TBL] [Abstract][Full Text] [Related]
4. Development of an automated system for preparation of liquid scintillation counting samples for radiolabeled pharmaceuticals. Marques R; Bernardoni F; Pollack S; Helmy R J Labelled Comp Radiopharm; 2014 Mar; 57(3):121-4. PubMed ID: 24327404 [TBL] [Abstract][Full Text] [Related]
5. [Chemiluminescence in a toluene-fenoxol scintillation system in the radioreceptor method of researching biological membranes]. Belokoneva OS; Kolomiĭtseva GIa Nauchnye Doki Vyss Shkoly Biol Nauki; 1990; (7):157-60. PubMed ID: 2248983 [TBL] [Abstract][Full Text] [Related]
6. Effects of tetrachloroethene on the measurement of radon in water with liquid scintillation counting method. Chen YT; Lu CJ J Environ Radioact; 2014 Jan; 127():26-33. PubMed ID: 24125902 [TBL] [Abstract][Full Text] [Related]
7. [Continuous measurement by liquid scintillation counting of CO2--14C expired by an animal]. Simonnet F; Simonnet G Int J Appl Radiat Isot; 1978 Oct; 29(9-10):589-92. PubMed ID: 748184 [No Abstract] [Full Text] [Related]
9. Adding water to liquid scintillation cocktail for laboratory wipe tests. Sturchio GM; King GR; Dorman MJ; Meechan PJ Health Phys; 1999 Feb; 76(2 Suppl):S32-6. PubMed ID: 9930838 [TBL] [Abstract][Full Text] [Related]
10. [Experimental study on in vivo erythrocyte labeling with 99m Tc using stannous chloride]. Hiraki T; Katayama M; Ando I; Ando A; Hisada K Kaku Igaku; 1982 Apr; 19(3):399-408. PubMed ID: 6290721 [No Abstract] [Full Text] [Related]
11. Chemiluminescence response in normal human phagocytes. I. Automated measurements using a standard liquid scintillation counter. Robinson JP; Penny R J Clin Lab Immunol; 1982 Apr; 7(3):215-7. PubMed ID: 7097747 [TBL] [Abstract][Full Text] [Related]
12. A microplate solid scintillation counter as a radioactivity detector for high performance liquid chromatography in drug metabolism: validation and applications. Bruin GJ; Waldmeier F; Boernsen KO; Pfaar U; Gross G; Zollinger M J Chromatogr A; 2006 Nov; 1133(1-2):184-94. PubMed ID: 16970958 [TBL] [Abstract][Full Text] [Related]
14. Photoactivated zinc silicate in thin layer chromatography plates: a potential cause for error in liquid scintillation counting. Tobias B; Strickler RC Steroids; 1981 Feb; 37(2):213-21. PubMed ID: 7013161 [TBL] [Abstract][Full Text] [Related]
15. Solid scintillation counting: a new technique for measuring radiolabeled compounds. Wunderly SW Int J Rad Appl Instrum A; 1989; 40(7):569-73. PubMed ID: 2551857 [TBL] [Abstract][Full Text] [Related]
16. A quick liquid scintillation counting technique for analysis of ⁹⁰Sr in environmental samples. Wang JJ Appl Radiat Isot; 2013 Nov; 81():169-74. PubMed ID: 23582495 [TBL] [Abstract][Full Text] [Related]
17. [Simultaneous measurement of 32P and a 33P double-labelled sample by liquid scintillation counter and its application to phosphorus compounds isolated by paper chromatography]. Sasaki Y; Arima Y; Kumazawa K Radioisotopes; 1982 Jun; 31(6):279-84. PubMed ID: 7178536 [TBL] [Abstract][Full Text] [Related]
18. The solvent action of sodium hypochlorite on fixed and unfixed necrotic tissue. Thé SD Oral Surg Oral Med Oral Pathol; 1979 Jun; 47(6):558-61. PubMed ID: 286277 [TBL] [Abstract][Full Text] [Related]
19. Reducing the effect of chemiluminescence on the efficiency of extracting 14C-neomycin from fortified kidney tissue as measured by a liquid scintillation system. Gridley JC; Allen EH; Shaikh B Int J Rad Appl Instrum B; 1986; 13(1):57-61. PubMed ID: 3771237 [TBL] [Abstract][Full Text] [Related]
20. Liquid scintillation counting of aqueous suspensions of microbiological specimens in a Triton X-100/toluene scintillant. Zarybnicky V; Reich M Anal Biochem; 1980 Jan; 101(2):476-82. PubMed ID: 6987915 [No Abstract] [Full Text] [Related] [Next] [New Search]