1. Acoustic Sensors for Monitoring and Localizing Partial Discharge Signals in Oil-Immersed Transformers under Array Configuration. Wang Y; Zhao D; Jia Y; Wang S; Du Y; Li H; Zhang B Sensors (Basel); 2024 Jul; 24(14):. PubMed ID: 39066101 [TBL] [Abstract][Full Text] [Related]
2. Localization for Dual Partial Discharge Sources in Transformer Oil Using Pressure-Balanced Fiber-Optic Ultrasonic Sensor Array. Liu F; Shi Y; Zhang S; Wang W Sensors (Basel); 2024 Jul; 24(14):. PubMed ID: 39065847 [TBL] [Abstract][Full Text] [Related]
3. Impact of Power Transformer Oil-Temperature on the Measurement Uncertainty of All-Acoustic Non-Iterative Partial Discharge Location. Polužanski V; Kartalović N; Nikolić B Materials (Basel); 2021 Mar; 14(6):. PubMed ID: 33809223 [TBL] [Abstract][Full Text] [Related]
4. Development of Acoustic Emission Sensor Optimized for Partial Discharge Monitoring in Power Transformers. Sikorski W Sensors (Basel); 2019 Apr; 19(8):. PubMed ID: 31003527 [TBL] [Abstract][Full Text] [Related]
5. Use of ultrasonic array method for positioning multiple partial discharge sources in transformer oil. Xie Q; Tao J; Wang Y; Geng J; Cheng S; Lü F Rev Sci Instrum; 2014 Aug; 85(8):084705. PubMed ID: 25173293 [TBL] [Abstract][Full Text] [Related]
6. Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors. Castro B; Clerice G; Ramos C; Andreoli A; Baptista F; Campos F; Ulson J Sensors (Basel); 2016 Aug; 16(8):. PubMed ID: 27517931 [TBL] [Abstract][Full Text] [Related]
7. An experimental validation of partial discharge localization using electromagnetic time reversal. Karami H; Azadifar M; Rubinstein M; Rachidi F Sci Rep; 2021 Jan; 11(1):220. PubMed ID: 33420279 [TBL] [Abstract][Full Text] [Related]
8. Phased-ultrasonic receiving-planar array transducer for partial discharge location in transformer. Yongfen L; Shengchang J; Yanming L IEEE Trans Ultrason Ferroelectr Freq Control; 2006 Mar; 53(3):614-22. PubMed ID: 16555770 [TBL] [Abstract][Full Text] [Related]
9. Towards Precise Interpretation of Oil Transformers via Novel Combined Techniques Based on DGA and Partial Discharge Sensors. Ward SA; El-Faraskoury A; Badawi M; Ibrahim SA; Mahmoud K; Lehtonen M; Darwish MMF Sensors (Basel); 2021 Mar; 21(6):. PubMed ID: 33810187 [TBL] [Abstract][Full Text] [Related]
10. Study of the Influence of Winding and Sensor Design on Ultra-High Frequency Partial Discharge Signals in Power Transformers. Beura CP; Beltle M; Tenbohlen S Sensors (Basel); 2020 Sep; 20(18):. PubMed ID: 32911783 [TBL] [Abstract][Full Text] [Related]
11. Locating Partial Discharges in Power Transformers with Convolutional Iterative Filtering. Wang J; Wu K; Sim A; Hwangbo S Sensors (Basel); 2023 Feb; 23(4):. PubMed ID: 36850386 [TBL] [Abstract][Full Text] [Related]
12. Partial Discharge Localization Using Time Reversal: Application to Power Transformers. Karami H; Azadifar M; Mostajabi A; Rubinstein M; Karami H; Gharehpetian GB; Rachidi F Sensors (Basel); 2020 Mar; 20(5):. PubMed ID: 32150914 [TBL] [Abstract][Full Text] [Related]
13. An Acoustic Localization Sensor Based on MEMS Microphone Array for Partial Discharge. Yan J; Chen C; Wu Z; Ding X; Lou L Sensors (Basel); 2023 Jan; 23(3):. PubMed ID: 36772119 [TBL] [Abstract][Full Text] [Related]
14. A Comparative Analysis Applied to the Partial Discharges Identification in Dry-Type Transformers by Hall and Acoustic Emission Sensors. de Castro BA; Dos Santos VV; Lucas GB; Ardila-Rey JA; Riehl RR; Andreoli AL Sensors (Basel); 2022 Feb; 22(5):. PubMed ID: 35270863 [TBL] [Abstract][Full Text] [Related]
15. Effect of sensor position on the measurement of acoustic wave produced by partial discharges. Fonkou Kongne BB; Mengata Mengounou G; Nkouetcha ET; Imano AM Heliyon; 2024 Feb; 10(4):e25974. PubMed ID: 38390110 [TBL] [Abstract][Full Text] [Related]
16. A Classification Method for Select Defects in Power Transformers Based on the Acoustic Signals. Kunicki M; Wotzka D Sensors (Basel); 2019 Nov; 19(23):. PubMed ID: 31795074 [TBL] [Abstract][Full Text] [Related]
17. UHF Partial Discharge Location in PowerTransformers via Solution of the MaxwellEquations in a Computational Environment. Nobrega L; Costa E; Serres A; Xavier G; Aquino M Sensors (Basel); 2019 Aug; 19(15):. PubMed ID: 31387324 [TBL] [Abstract][Full Text] [Related]
18. Moisture Prediction of Transformer Oil-Immersed Polymer Insulation by Applying a Support Vector Machine Combined with a Genetic Algorithm. Zhang Y; Li J; Fan X; Liu J; Zhang H Polymers (Basel); 2020 Jul; 12(7):. PubMed ID: 32708631 [TBL] [Abstract][Full Text] [Related]
19. Fault diagnosis method for oil-immersed transformers integrated digital twin model. Yao H; Zhang X; Guo Q; Miao Y; Guan S Sci Rep; 2024 Sep; 14(1):20355. PubMed ID: 39223198 [TBL] [Abstract][Full Text] [Related]
20. Accurate Assessment of Moisture Content and Degree of Polymerization in Power Transformers via Dielectric Response Sensing. Kunakorn A; Pramualsingha S; Yutthagowith P; Nimsanong P; Kittiratsatcha S Sensors (Basel); 2023 Oct; 23(19):. PubMed ID: 37837066 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]