These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 39069397)

  • 1. Development and promotion of a 3D-printed phantom model for ultrasound-guided caudal block followed by intracavitary/interstitial brachytherapy for gynecological cancer.
    Kawamoto T; Oshima M; Murakami N; Okonogi N; Muramoto Y; Karino T; Iijima K; Takatsu J; Inoue T; Shikama N
    Brachytherapy; 2024; 23(5):590-594. PubMed ID: 39069397
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Low-cost 3D print-based phantom fabrication to facilitate interstitial prostate brachytherapy training program.
    Chiu T; Xiong Z; Parsons D; Folkert MR; Medin PM; Hrycushko B
    Brachytherapy; 2020; 19(6):800-811. PubMed ID: 32690386
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multimaterial three-dimensional printing in brachytherapy: Prototyping teaching tools for interstitial and intracavitary procedures in cervical cancers.
    Campelo S; Subashi E; Meltsner SG; Chang Z; Chino J; Craciunescu O
    Brachytherapy; 2020; 19(6):767-776. PubMed ID: 32893145
    [TBL] [Abstract][Full Text] [Related]  

  • 4. 3D-printed Magnetic Resonance (MR)-based gynecological phantom for image-guided brachytherapy training.
    Kut C; Kao T; Morcos M; Kim Y; Boctor E; Viswanathan AN
    Brachytherapy; 2022; 21(6):799-805. PubMed ID: 36050143
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Toward a 3D transrectal ultrasound system for verification of needle placement during high-dose-rate interstitial gynecologic brachytherapy.
    Rodgers JR; Surry K; Leung E; D'Souza D; Fenster A
    Med Phys; 2017 May; 44(5):1899-1911. PubMed ID: 28295403
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multipurpose ultrasound-based prostate phantom for use in interstitial brachytherapy.
    Shaaer A; Alrashidi S; Chung H; Loblaw A; Morton G; Paudel M; Tseng CL; Ravi A
    Brachytherapy; 2021; 20(6):1139-1145. PubMed ID: 34420861
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel multi-modality imaging phantom for validating interstitial needle guidance for high dose rate gynecological brachytherapy.
    Eckroate B; Ayala-Peacock D; Venkataraman R; Campelo S; Chino J; Stephens SJ; Kim Y; Meltsner S; Raffi J; Craciunescu O
    J Appl Clin Med Phys; 2023 Oct; 24(10):e14075. PubMed ID: 37335537
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultrasound-guided versus conventional injection for caudal block in children: A prospective randomized clinical study.
    Ahiskalioglu A; Yayik AM; Ahiskalioglu EO; Ekinci M; Gölboyu BE; Celik EC; Alici HA; Oral A; Demirdogen SO
    J Clin Anesth; 2018 Feb; 44():91-96. PubMed ID: 29161549
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hands-on-training tailored in response to pre-questionnaire-based survey on image-guided brachytherapy effectively reduces anxiety about its implementation.
    Okonogi N; Murakami N; Takatsu J; Iijima K; Kawamoto T; Oshima M; Okuma K; Masui K; Murata K; Okamoto H; Yoshida K; Noda SE; Numajiri H; Watanabe M; Tsuchida K; Muramoto Y; Karino T; Ohno T; Shikama N
    J Radiat Res; 2024 May; 65(3):323-327. PubMed ID: 38544297
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of deformable image registration between external beam radiotherapy and HDR brachytherapy for cervical cancer with a 3D-printed deformable pelvis phantom.
    Kadoya N; Miyasaka Y; Nakajima Y; Kuroda Y; Ito K; Chiba M; Sato K; Dobashi S; Yamamoto T; Takahashi N; Kubozono M; Takeda K; Jingu K
    Med Phys; 2017 Apr; 44(4):1445-1455. PubMed ID: 28214368
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A radiopaque 3D printed, anthropomorphic phantom for simulation of CT-guided procedures.
    Jahnke P; Schwarz FB; Ziegert M; Almasi T; Abdelhadi O; Nunninger M; Hamm B; Scheel M
    Eur Radiol; 2018 Nov; 28(11):4818-4823. PubMed ID: 29789910
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Building Affordable, Durable, Medium-fidelity Ballistic Gel Phantoms for Ultrasound-guided Nerve Block Training.
    Marsh-Armstrong BP; Ryan JF; Mariano DJ; Suresh PJ; Supat B
    J Vis Exp; 2024 Feb; (204):. PubMed ID: 38407270
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Caudal epidural anesthesia during intracavitary brachytherapy for cervical cancer.
    Isoyama-Shirakawa Y; Nakamura K; Abe M; Kunitake N; Matsumoto K; Ohga S; Sasaki T; Uehara S; Okushima K; Shioyama Y; Honda H
    J Radiat Res; 2015 May; 56(3):583-7. PubMed ID: 25852151
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Three-dimensional trans-rectal and trans-abdominal ultrasound image fusion for the guidance of gynecologic brachytherapy procedures: a proof of concept study.
    Trumpour T; du Toit C; van Gaalen A; Park CKS; Rodgers JR; Mendez LC; Surry K; Fenster A
    Sci Rep; 2024 Aug; 14(1):18459. PubMed ID: 39117682
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Can combined intracavitary/interstitial approach be an alternative to interstitial brachytherapy with the Martinez Universal Perineal Interstitial Template (MUPIT) in computed tomography-guided adaptive brachytherapy for bulky and/or irregularly shaped gynecological tumors?
    Oike T; Ohno T; Noda SE; Kiyohara H; Ando K; Shibuya K; Tamaki T; Takakusagi Y; Sato H; Nakano T
    Radiat Oncol; 2014 Oct; 9():222. PubMed ID: 25319341
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Alternative way to find sacral hiatus for blind caudal block - Based on 3D pelvis CT anthropometry: A retrospective study.
    Oh S; Chung K; Bang S; Kim SY; Kwon W
    Med Hypotheses; 2018 Dec; 121():70-73. PubMed ID: 30396497
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Training Course for Simulating Head and Neck Ultrasound-Guided Procedures Using a Gelatin Phantom Model.
    Cheng PC; Lo WC; Chang CM; Wen MH; Liao LJ
    Ann Otol Rhinol Laryngol; 2024 Sep; 133(9):792-799. PubMed ID: 38898810
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A randomized comparison of caudal block by sacral hiatus injection under ultrasound guidance with traditional sacral canal injection in children.
    Wang LZ; Hu XX; Zhang YF; Chang XY
    Paediatr Anaesth; 2013 May; 23(5):395-400. PubMed ID: 23278906
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optical fibre based real-time measurements during an LDR prostate brachytherapy implant simulation: using a 3D printed anthropomorphic phantom.
    Woulfe P; Sullivan FJ; Byrne L; Doyle AJ; Kam W; Martyn M; O'Keeffe S
    Sci Rep; 2021 May; 11(1):11160. PubMed ID: 34045648
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Low-cost three-dimensional printed phantom for neuraxial anesthesia training: Development and comparison to a commercial model.
    Mashari A; Montealegre-Gallegos M; Jeganathan J; Yeh L; Qua Hiansen J; Meineri M; Mahmood F; Matyal R
    PLoS One; 2018; 13(6):e0191664. PubMed ID: 29912877
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.