BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 3907015)

  • 1. Circulating immune complex-like materials which bind to heat inactivated C1q interfere with the C1q solid phase assay for immune complexes.
    Fukuda K; Seino J; Kinoshita Y; Sudo K; Horigome I; Saito T; Furuyama T; Yoshinaga K
    Tohoku J Exp Med; 1985 Aug; 146(4):449-56. PubMed ID: 3907015
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A solid phase C1q enzyme assay for circulating immune complexes adapted for routine clinical laboratory testing.
    James K; Vahey A; Robinson M; Marder R
    Am J Clin Pathol; 1983 Oct; 80(4):445-52. PubMed ID: 6353904
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of anti-C1q capture assay for detecting circulating immune complexes and comparison with polyethylene glycol-immunoglobulin G, C1q-binding, and Raji cell methods.
    Levinson SS; Goldman JO
    J Clin Microbiol; 1987 Aug; 25(8):1567-9. PubMed ID: 2957387
    [TBL] [Abstract][Full Text] [Related]  

  • 4. C1q solid-phase radioimmunoassay: binding properties of solid-phase C1q and evidence that C1q-binding IgG complexes in systemic lupus erythematosus are not bound to endogenous C1q.
    Uwatoko S; Aotsuka S; Okawa M; Egusa Y; Yokohari R; Aizawa C; Suzuki K
    J Immunol Methods; 1984 Oct; 73(1):67-74. PubMed ID: 6436382
    [TBL] [Abstract][Full Text] [Related]  

  • 5. C1q-latex assay for immune complexes. Complexes that react with both C1q and monoclonal rheumatoid factor in lupus erythematosus and lung cancer.
    Medof ME
    J Lab Clin Med; 1982 May; 99(5):678-92. PubMed ID: 6978370
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evidence for the presence of autoantibodies to the collagen-like portion of C1q in systemic lupus erythematosus.
    Antes U; Heinz HP; Loos M
    Arthritis Rheum; 1988 Apr; 31(4):457-64. PubMed ID: 3258749
    [TBL] [Abstract][Full Text] [Related]  

  • 7. C1q solid-phase radioimmunoassay: evidence for detection of antibody directed against the collagen-like region of C1q in sera from patients with systemic lupus erythematosus.
    Uwatoko S; Aotsuka S; Okawa M; Egusa Y; Yokohari R; Aizawa C; Suzuki K
    Clin Exp Immunol; 1987 Jul; 69(1):98-106. PubMed ID: 3498589
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Detection of C1q-bearing immune complexes by a monoclonal anti-C1q ELISA system.
    Antes U; Heinz HP; Loos M
    J Immunol Methods; 1987 Sep; 102(2):149-56. PubMed ID: 2443573
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The IgG detected in the C1q solid-phase immune-complex assay is not always of immune-complex nature.
    Hack CE; Belmer AJ
    Clin Immunol Immunopathol; 1986 Jan; 38(1):120-8. PubMed ID: 3484437
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Correlation of C3d fixing circulating immune complexes with disease activity and clinical parameters in patients with systemic lupus erythematosus.
    Sekita K; Doi T; Muso E; Yoshida H; Kanatsu K; Hamashima Y
    Clin Exp Immunol; 1984 Mar; 55(3):487-94. PubMed ID: 6608422
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Demonstration of circulating immune complexes using a C1q-solid phase enzyme immunoassay].
    Schössler W; Hiepe F; Courault K; Porstmann B; Apostoloff E
    Biomed Biochim Acta; 1983; 42(7-8):1027-35. PubMed ID: 6360166
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of C1q-binding IgG complexes in systemic lupus erythematosus.
    Uwatoko S; Aotsuka S; Okawa M; Egusa Y; Yokohari R; Aizawa C; Suzuki K
    Clin Immunol Immunopathol; 1984 Jan; 30(1):104-16. PubMed ID: 6421520
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rapid three-step purification procedure for isolation of the C1q component of human complement and its use in a solid-phase C1q binding assay.
    Bähr EA; Drahovsky D
    J Immunol Methods; 1984 Apr; 69(1):43-50. PubMed ID: 6325543
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurement of circulating immune complexes in human sera by enzyme immunoassay.
    Cheung K; O'Kane D; Robinson MF
    Aust J Exp Biol Med Sci; 1982 Dec; 60(6):593-605. PubMed ID: 6820632
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Immune complexes of IgG1 and IgG3 subclasses in human breast cancer sera detected by monoclonal antibodies in an indirect immunoenzymatic assay.
    Manzo C; Bianchin A; Pirozzi G; Totaro G
    Oncology; 1983; 40(6):395-9. PubMed ID: 6358985
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Circulating immune complexes in systemic lupus erythematosus: a reappraisal of the solid phase C1q radioimmunoassay.
    Woodroffe AJ; Nozza JM; Muller KD; McIntosh SL; Hale GM; Clarkson AR
    J Clin Lab Immunol; 1988 May; 26(1):5-7. PubMed ID: 3263507
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Polyethylene glycol enhances the binding of C1q to circulating immune complexes.
    Hack CE; Eerenberg-Belmer AJ; Hannema AJ; Out TA; Aalberse RC
    J Immunol Methods; 1981; 44(2):211-21. PubMed ID: 6792284
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The detection of circulating immune complexes containing C1q and IgG using a new rapid serum ELISA test system.
    Reckel RP; Harris J; Botsko E; Wellerson R; Varga S
    Diagn Immunol; 1984; 2(4):228-37. PubMed ID: 6335421
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The complement fixing ability of putative circulating immune complexes in rheumatoid arthritis and its relationship to extra-articular disease.
    Bourke BE; Moss IK; Mumford P; Horsfall A; Maini RN
    Clin Exp Immunol; 1982 Jun; 48(3):726-32. PubMed ID: 6981475
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Circulating immune complexes in idiopathic glomerular disease.
    Cairns SA; London RA; Mallick NP
    Kidney Int; 1982 Mar; 21(3):507-12. PubMed ID: 6979654
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.