4. Measurements of neutron fluxes from tokamak plasmas using a compact neutron spectrometer. Iliasova MV; Shevelev AE; Khilkevitch EM; Lebedev SV; Askinazi LG; Kornev VA; Minaev VB; Tukachinsky AS; Doinikov DN; Polunovsky IA; Naidenov VO; Gin DB Rev Sci Instrum; 2021 Apr; 92(4):043560. PubMed ID: 34243451 [TBL] [Abstract][Full Text] [Related]
5. Characterisation of a BC501A compact neutron spectrometer for fusion research. Tardini G; Gagnon-Moisan F; Zimbal A Rev Sci Instrum; 2016 Oct; 87(10):103504. PubMed ID: 27802709 [TBL] [Abstract][Full Text] [Related]
6. Optimization of MAXED input parameters with applications to the unfolding of neutron diagnostics data from the Joint European Torus. Giacomelli L; Reginatto M; Rev Sci Instrum; 2019 Sep; 90(9):093505. PubMed ID: 31575238 [TBL] [Abstract][Full Text] [Related]
7. A compact stilbene crystal neutron spectrometer for NBI-heated plasma neutron diagnostics at EAST. Liao LY; Zhang YM; Hu ZM; Yang DK; Ge LJ; Sun JQ; Zhong GQ; Hu LQ; Wan BN; Gorini G; Nocente M; Tardocchi M; Li XQ; Fan TS Rev Sci Instrum; 2021 Apr; 92(4):043506. PubMed ID: 34243369 [TBL] [Abstract][Full Text] [Related]
8. Measurement and simulation of the response function of time of flight enhanced diagnostics neutron spectrometer for beam ion studies at EAST tokamak. Peng XY; Chen ZJ; Zhang X; Du TF; Hu ZM; Ge LJ; Zhang YM; Sun JQ; Gorini G; Nocente M; Tardocchi M; Hu LQ; Zhong GQ; Pu N; Lin SY; Wan BN; Li XQ; Zhang GH; Chen JX; Fan TS Rev Sci Instrum; 2016 Nov; 87(11):11D836. PubMed ID: 27910376 [TBL] [Abstract][Full Text] [Related]
9. A diamond based neutron spectrometer for diagnostics of deuterium-tritium fusion plasmas. Cazzaniga C; Nocente M; Rebai M; Tardocchi M; Calvani P; Croci G; Giacomelli L; Girolami M; Griesmayer E; Grosso G; Pillon M; Trucchi DM; Gorini G Rev Sci Instrum; 2014 Nov; 85(11):11E101. PubMed ID: 25430280 [TBL] [Abstract][Full Text] [Related]
10. Observations of core ion cyclotron emission on ASDEX Upgrade tokamak. Ochoukov R; Bobkov V; Chapman B; Dendy R; Dunne M; Faugel H; García-Muñoz M; Geiger B; Hennequin P; McClements KG; Moseev D; Nielsen S; Rasmussen J; Schneider P; Weiland M; Noterdaeme JM; ; Rev Sci Instrum; 2018 Oct; 89(10):10J101. PubMed ID: 30399687 [TBL] [Abstract][Full Text] [Related]
12. Neutron emission spectroscopy of D plasmas at JET with a compact liquid scintillating neutron spectrometer. Giacomelli L; Belli F; Binda F; Conroy SW; Eriksson J; Milocco A; Popovicev S; Syme DB; Rev Sci Instrum; 2018 Oct; 89(10):10I113. PubMed ID: 30399806 [TBL] [Abstract][Full Text] [Related]
13. Profile measurements of the electron temperature on the ASDEX Upgrade, COMPASS, and ISTTOK tokamak using Thomson scattering, triple, and ball-pen probes. Adamek J; Müller HW; Silva C; Schrittwieser R; Ionita C; Mehlmann F; Costea S; Horacek J; Kurzan B; Bilkova P; Böhm P; Aftanas M; Vondracek P; Stöckel J; Panek R; Fernandes H; Figueiredo H Rev Sci Instrum; 2016 Apr; 87(4):043510. PubMed ID: 27131677 [TBL] [Abstract][Full Text] [Related]
14. Design and optimization of an advanced time-of-flight neutron spectrometer for deuterium plasmas of the large helical device. Zhang Y; Ge L; Hu Z; Sun J; Li X; Ogawa K; Isobe M; Sangaroon S; Liao L; Yang D; Gorini G; Nocente M; Tardocchi M; Fan T Rev Sci Instrum; 2021 May; 92(5):053547. PubMed ID: 34243352 [TBL] [Abstract][Full Text] [Related]
15. Scintillator based detector for fast-ion losses induced by magnetohydrodynamic instabilities in the ASDEX upgrade tokamak. García-Muñoz M; Fahrbach HU; Zohm H; Rev Sci Instrum; 2009 May; 80(5):053503. PubMed ID: 19499603 [TBL] [Abstract][Full Text] [Related]
16. A compact stilbene crystal neutron spectrometer for EAST D-D plasma neutron diagnostics. Zhang X; Yuan X; Xie X; Chen Z; Peng X; Chen J; Zhang G; Li X; Fan T; Zhong G; Hu L; Wan B Rev Sci Instrum; 2013 Mar; 84(3):033506. PubMed ID: 23556820 [TBL] [Abstract][Full Text] [Related]
17. Gamma-ray spectroscopy at MHz counting rates with a compact LaBr Nocente M; Rigamonti D; Perseo V; Tardocchi M; Boltruczyk G; Broslawski A; Cremona A; Croci G; Gosk M; Kiptily V; Korolczuk S; Mazzocco M; Muraro A; Strano E; Zychor I; Gorini G; Rev Sci Instrum; 2016 Nov; 87(11):11E714. PubMed ID: 27910625 [TBL] [Abstract][Full Text] [Related]
18. First measurements of a scintillator based fast-ion loss detector near the ASDEX Upgrade divertor. Gonzalez-Martin J; Ayllon-Guerola J; Garcia-Munoz M; Herrmann A; Leitenstern P; De Marne P; Zoletnik S; Kovacsik A; Galdon-Quiroga J; Rivero-Rodriguez J; Rodriguez-Ramos M; Sanchis-Sanchez L; Dominguez J; ; Rev Sci Instrum; 2018 Oct; 89(10):10I106. PubMed ID: 30399966 [TBL] [Abstract][Full Text] [Related]
19. Velocity-space sensitivity of the compact neutron emission spectrometers at EAST. Zhang YM; Ge LJ; Sun JQ; Hu ZM; Nocente M; Gorini G; Tardocchi M; Zhong GQ; Hu LQ; Li XQ; Fan TS Rev Sci Instrum; 2018 Oct; 89(10):10I141. PubMed ID: 30399743 [TBL] [Abstract][Full Text] [Related]
20. Design and simulation of an imaging neutral particle analyzer for the ASDEX Upgrade tokamak. Rueda-Rueda J; García-Muñoz M; Viezzer E; Schneider PA; García-Domínguez J; Ayllon-Guerola J; Galdón-Quiroga J; Herrmann A; Du XD; Van Zeeland MA; Oyola P; Rodriguez-Ramos M; Rev Sci Instrum; 2021 Apr; 92(4):043554. PubMed ID: 34243403 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]