These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 3908815)

  • 1. An acoustic plethysmograph to measure total infant body volume.
    Deskins WG; Winter DC; Sheng HP; Garza C
    J Biomech Eng; 1985 Nov; 107(4):304-8. PubMed ID: 3908815
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of resonating cavity to measure body volume.
    Deskins WG; Winter DC; Sheng HP; Garza C
    J Acoust Soc Am; 1985 Feb; 77(2):756-8. PubMed ID: 3973244
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Body volume and fat-free mass determinations by acoustic plethysmography.
    Sheng HP; Adolph AL; Smith EO; Garza C
    Pediatr Res; 1988 Jul; 24(1):85-9. PubMed ID: 3412851
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Unrestrained acoustic plethysmograph for measuring tidal volume in mice.
    Reynolds JS; Frazer DG
    Ann Biomed Eng; 2006 Sep; 34(9):1494-9. PubMed ID: 16897419
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pre-term infant volume measurements by acoustic plethysmography.
    Valerio Jiménez OS; Moon JK; Jensen CL; Vohra FA; Sheng HP
    J Biomed Eng; 1993 Mar; 15(2):91-8. PubMed ID: 8459703
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new air displacement plethysmograph for the measurement of body composition in infants.
    Urlando A; Dempster P; Aitkens S
    Pediatr Res; 2003 Mar; 53(3):486-92. PubMed ID: 12595599
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of the thermodynamics of an infant plethysmograph on the measurement of thoracic gas volume.
    Sly PD; Lanteri C; Bates JH
    Pediatr Pulmonol; 1990; 8(3):203-8. PubMed ID: 2349011
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Correcting for the thermodynamic characteristics of a body plethysmograph.
    Bates JH
    Ann Biomed Eng; 1989; 17(6):647-55. PubMed ID: 2589696
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A high frequency response volume displacement body plethysmograph.
    Skoogh BE; Rizell S
    Scand J Clin Lab Invest; 1973 Jun; 31(4):419-27. PubMed ID: 4761790
    [No Abstract]   [Full Text] [Related]  

  • 10. Volume-displacement body plethysmograph using a large flowmeter without pressure compensation.
    Griffin PM; Zamel N
    J Appl Physiol Respir Environ Exerc Physiol; 1979 Nov; 47(5):1127-30. PubMed ID: 159885
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An electronic processor for use with a whole body plethysmograph to determine specific airways conductance.
    Smith RE; Jones DP; O'Connor SA
    J Biomed Eng; 1987 Oct; 9(4):305-12. PubMed ID: 3682794
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Acoustic plethysmography measures breathing in unrestrained neonatal mice.
    Daubenspeck JA; Li A; Nattie EE
    J Appl Physiol (1985); 2008 Jan; 104(1):262-8. PubMed ID: 17962574
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of an air displacement method for whole body volume measurement of infants.
    Taylor A; Aksoy Y; Scopes JW; du Mont G; Taylor BA
    J Biomed Eng; 1985 Jan; 7(1):9-17. PubMed ID: 3982015
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Man-Cans. (Conclusion). The body plethysmograph (body box).
    Comroe JH
    Am Rev Respir Dis; 1977 Dec; 116(6):1091-9. PubMed ID: 337866
    [No Abstract]   [Full Text] [Related]  

  • 15. Unrestrained acoustic plethysmograph for measuring specific airway resistance in mice.
    Reynolds JS; Johnson VJ; Frazer DG
    J Appl Physiol (1985); 2008 Aug; 105(2):711-7. PubMed ID: 18450981
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Examination of tidal volume and ventilation in infants in the first six months of life by means of whole-body plethysmograph (author's transl)].
    Michalicková J; Soltés L; Jakubík J
    Bratisl Lek Listy; 1979 Feb; 71(2):129-36. PubMed ID: 427607
    [No Abstract]   [Full Text] [Related]  

  • 17. Calculation of lung volume in newborn infants by means of a computer-assisted nitrogen washout method.
    Sjöqvist BA; Sandberg K; Hjalmarson O; Olsson T
    Pediatr Res; 1984 Nov; 18(11):1160-4. PubMed ID: 6514441
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of electronic compensation on plethysmographic airway resistance measurements.
    Broughton S; Rafferty GF; Milner AD; Greenough A
    Pediatr Pulmonol; 2007 Sep; 42(9):764-72. PubMed ID: 17659604
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A constant-volume whole-body plethysmograph with a self-closing door.
    McIlreath FJ
    J Appl Physiol; 1972 Apr; 32(4):565-6. PubMed ID: 5026512
    [No Abstract]   [Full Text] [Related]  

  • 20. Hyperbaric whole-body plethysmograph for rodents.
    Lin YC; Shida KK; Respicio BL
    Undersea Biomed Res; 1983 Jun; 10(2):135-45. PubMed ID: 6612899
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.