These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 39106206)

  • 1. Closed-Loop Insulin Therapy for People With Type 2 Diabetes Treated With an Insulin Pump: A 12-Week Multicenter, Open-Label Randomized, Controlled, Crossover Trial.
    Borel AL; Lablanche S; Waterlot C; Joffray E; Barra C; Arnol N; Amougay H; Benhamou PY
    Diabetes Care; 2024 Oct; 47(10):1778-1786. PubMed ID: 39106206
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fully Closed-Loop Glucose Control Compared With Insulin Pump Therapy With Continuous Glucose Monitoring in Adults With Type 1 Diabetes and Suboptimal Glycemic Control: A Single-Center, Randomized, Crossover Study.
    Boughton CK; Hartnell S; Lakshman R; Nwokolo M; Wilinska ME; Ware J; Allen JM; Evans ML; Hovorka R
    Diabetes Care; 2023 Nov; 46(11):1916-1922. PubMed ID: 37616583
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hybrid Closed Loop Using a Do-It-Yourself Artificial Pancreas System in Adults With Type 1 Diabetes.
    Nanayakkara N; Sharifi A; Burren D; Elghattis Y; Jayarathna DK; Cohen N
    J Diabetes Sci Technol; 2024 Jul; 18(4):889-896. PubMed ID: 36788715
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Glucose Variability and Time in Range in Type 2 Diabetes Treated with U-500R by Pump or Injection: CGM Findings from the VIVID Study.
    Blevins T; Lane W; Rodbard D; Sindelar D; Fan L; Ellinor K; Ilag L; Ly T; Johnson J
    Diabetes Technol Ther; 2021 Jan; 23(1):51-58. PubMed ID: 32631081
    [No Abstract]   [Full Text] [Related]  

  • 5. Advanced Hybrid Closed Loop in Adult Population With Type 1 Diabetes: A Substudy From the ADAPT Randomized Controlled Trial in Users of Real-Time Continuous Glucose Monitoring.
    van den Heuvel T; Kolassa R; Keuthage W; Kroeger J; Ré R; de Portu S; Vorrink L; Shin J; Castañeda J; Vigersky R; Cohen O
    J Diabetes Sci Technol; 2024 Sep; 18(5):1132-1138. PubMed ID: 36949671
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparing the effectiveness of continuous subcutaneous insulin infusion with multiple daily insulin injection for patients with type 1 diabetes mellitus evaluated by retrospective continuous glucose monitoring: A real-world data analysis.
    Keyu G; Jiaqi L; Liyin Z; Jianan Y; Li F; Zhiyi D; Qin Z; Xia L; Lin Y; Zhiguang Z
    Front Public Health; 2022; 10():990281. PubMed ID: 36091534
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of initiating use of an insulin pump in adults with type 1 diabetes using multiple daily insulin injections and continuous glucose monitoring (DIAMOND): a multicentre, randomised controlled trial.
    Beck RW; Riddlesworth TD; Ruedy KJ; Kollman C; Ahmann AJ; Bergenstal RM; Bhargava A; Bode BW; Haller S; Kruger DF; McGill JB; Polonsky W; Price D; Toschi E;
    Lancet Diabetes Endocrinol; 2017 Sep; 5(9):700-708. PubMed ID: 28711468
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.
    Rodbard D
    Diabetes Technol Ther; 2017 Jun; 19(S3):S25-S37. PubMed ID: 28585879
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Flexible insulin therapy with a hybrid regimen of insulin degludec and continuous subcutaneous insulin infusion with pump suspension before exercise in physically active adults with type 1 diabetes (FIT Untethered): a single-centre, open-label, proof-of-concept, randomised crossover trial.
    Aronson R; Li A; Brown RE; McGaugh S; Riddell MC
    Lancet Diabetes Endocrinol; 2020 Jun; 8(6):511-523. PubMed ID: 32445738
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Closed-Loop Insulin Delivery Versus Sensor-Augmented Pump Therapy in Older Adults With Type 1 Diabetes (ORACL): A Randomized, Crossover Trial.
    McAuley SA; Trawley S; Vogrin S; Ward GM; Fourlanos S; Grills CA; Lee MH; Alipoor AM; O'Neal DN; O'Regan NA; Sundararajan V; Colman PG; MacIsaac RJ
    Diabetes Care; 2022 Feb; 45(2):381-390. PubMed ID: 34844995
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Closed-loop insulin delivery in suboptimally controlled type 1 diabetes: a multicentre, 12-week randomised trial.
    Tauschmann M; Thabit H; Bally L; Allen JM; Hartnell S; Wilinska ME; Ruan Y; Sibayan J; Kollman C; Cheng P; Beck RW; Acerini CL; Evans ML; Dunger DB; Elleri D; Campbell F; Bergenstal RM; Criego A; Shah VN; Leelarathna L; Hovorka R;
    Lancet; 2018 Oct; 392(10155):1321-1329. PubMed ID: 30292578
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of technology on glycaemic control in type 2 diabetes: A meta-analysis of randomized trials on continuous glucose monitoring and continuous subcutaneous insulin infusion.
    Dicembrini I; Mannucci E; Monami M; Pala L
    Diabetes Obes Metab; 2019 Dec; 21(12):2619-2625. PubMed ID: 31368658
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Closed-loop insulin delivery in pregnant women with type 1 diabetes (CRISTAL): a multicentre randomized controlled trial - study protocol.
    Beunen K; Van Wilder N; Ballaux D; Vanhaverbeke G; Taes Y; Aers XP; Nobels F; Marlier J; Lee D; Cuypers J; Preumont V; Siegelaar SE; Painter RC; Laenen A; Gillard P; Mathieu C; Benhalima K
    BMC Pregnancy Childbirth; 2023 Mar; 23(1):180. PubMed ID: 36927458
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparing advanced hybrid closed loop therapy and standard insulin therapy in pregnant women with type 1 diabetes (CRISTAL): a parallel-group, open-label, randomised controlled trial.
    Benhalima K; Beunen K; Van Wilder N; Ballaux D; Vanhaverbeke G; Taes Y; Aers XP; Nobels F; Marlier J; Lee D; Cuypers J; Preumont V; Siegelaar SE; Painter RC; Laenen A; Gillard P; Mathieu C
    Lancet Diabetes Endocrinol; 2024 Jun; 12(6):390-403. PubMed ID: 38697182
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hybrid Closed-Loop Versus Manual Insulin Delivery in Adults With Type 1 Diabetes: A Post Hoc Analysis Using the Glycemia Risk Index.
    Lee MH; Vogrin S; Jones TW; O'Neal DN
    J Diabetes Sci Technol; 2024 Jul; 18(4):764-770. PubMed ID: 38372246
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of 6 months of hybrid closed-loop insulin delivery in adults with type 1 diabetes: a randomised controlled trial protocol.
    McAuley SA; de Bock MI; Sundararajan V; Lee MH; Paldus B; Ambler GR; Bach LA; Burt MG; Cameron FJ; Clarke PM; Cohen ND; Colman PG; Davis EA; Fairchild JM; Hendrieckx C; Holmes-Walker DJ; Horsburgh JC; Jenkins AJ; Kaye J; Keech AC; King BR; Kumareswaran K; MacIsaac RJ; McCallum RW; Nicholas JA; Sims C; Speight J; Stranks SN; Trawley S; Ward GM; Vogrin S; Jones TW; O'Neal DN
    BMJ Open; 2018 Jun; 8(6):e020274. PubMed ID: 29886443
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Six Months of Hybrid Closed-Loop Versus Manual Insulin Delivery With Fingerprick Blood Glucose Monitoring in Adults With Type 1 Diabetes: A Randomized, Controlled Trial.
    McAuley SA; Lee MH; Paldus B; Vogrin S; de Bock MI; Abraham MB; Bach LA; Burt MG; Cohen ND; Colman PG; Davis EA; Hendrieckx C; Holmes-Walker DJ; Kaye J; Keech AC; Kumareswaran K; MacIsaac RJ; McCallum RW; Sims CM; Speight J; Stranks SN; Sundararajan V; Trawley S; Ward GM; Jenkins AJ; Jones TW; O'Neal DN;
    Diabetes Care; 2020 Dec; 43(12):3024-3033. PubMed ID: 33055139
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Combined continuous glucose monitoring and subcutaneous insulin infusion versus self-monitoring of blood glucose with optimized multiple injections in people with type 1 diabetes: A randomized crossover trial.
    Dicembrini I; Pala L; Caliri M; Minardi S; Cosentino C; Monami M; Mannucci E
    Diabetes Obes Metab; 2020 Aug; 22(8):1286-1291. PubMed ID: 32166907
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Randomized Trial of Closed-Loop Control in Very Young Children with Type 1 Diabetes.
    Ware J; Allen JM; Boughton CK; Wilinska ME; Hartnell S; Thankamony A; de Beaufort C; Schierloh U; Fröhlich-Reiterer E; Mader JK; Kapellen TM; Rami-Merhar B; Tauschmann M; Nagl K; Hofer SE; Campbell FM; Yong J; Hood KK; Lawton J; Roze S; Sibayan J; Bocchino LE; Kollman C; Hovorka R;
    N Engl J Med; 2022 Jan; 386(3):209-219. PubMed ID: 35045227
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Treatment satisfaction and quality of life for an integrated continuous glucose monitoring/insulin pump system compared to self-monitoring plus an insulin pump.
    Rubin RR; Peyrot M
    J Diabetes Sci Technol; 2009 Nov; 3(6):1402-10. PubMed ID: 20144395
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.