These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 39129883)

  • 1. Novel Lithotripsy-Assisted Transcatheter Aortic Valve Replacement May Reduce Risk of Aortic Root Rupture.
    Seshiah P; Choo J; Garcia S; Kereiakes DJ
    J Soc Cardiovasc Angiogr Interv; 2023; 2(6Part A):101111. PubMed ID: 39129883
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bespoke valve sizing avoids annular rupture in patients treated with a balloon-expandable transcatheter heart valve.
    Chavarria J; Falcao F; Dutra G; Sathananthan J; Wood D; Douvi G; Natarajan M; Jaffer I; Velianou J; Sheth T
    Catheter Cardiovasc Interv; 2022 Nov; 100(5):823-831. PubMed ID: 36153648
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Lithotripsy-Assisted Transcatheter Mitral Valve Replacement for Severe Mitral Annular and Valve Calcification.
    Seshiah P; Garcia S; Choo J; Smith JM; Answini GA; Stewart T; Kereiakes DJ
    J Soc Cardiovasc Angiogr Interv; 2023; 2(1):100540. PubMed ID: 39132528
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Balloon Versus Computed Tomography Sizing of the Aortic Annulus for Transcatheter Aortic Valve Replacement and the Impact of Left Ventricular Outflow Tract Calcification and Morphology on Sizing.
    Condado JF; Lerakis S; Stewart J; Jensen H; Henry TS; Ko SM; Stillman A; Rajaei MH; Mavromatis K; Devireddy C; Sarin E; Leshnower B; Guyton R; Kaebnick B; Thourani VH; Block PC; Babaliaros V
    J Invasive Cardiol; 2016 Jul; 28(7):295-304. PubMed ID: 27101969
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Annular Rupture Due to Calcified Nodule Located in Left Ventricular Outflow Tract (LVOT) During Transcatheter Aortic Valve Replacement (TAVR) Managed by Protamine Sulfate.
    Chauhan S; Bhatnagar M; Jilani TN; Levisman J
    Cureus; 2023 Jan; 15(1):e33417. PubMed ID: 36751162
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intravascular lithotripsy (IVL) enabled the percutaneous closure of a severely calcified paravalvular leak regurgitation following implantation of a self-expandable transcatheter aortic valve: a case report.
    Evola S; D'Agostino A; Adorno D; Triolo OF; Giarratana G; Castrovinci S; Argano V; Onorato EM
    Front Cardiovasc Med; 2024; 11():1359711. PubMed ID: 38450376
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement.
    Barbanti M; Yang TH; Rodès Cabau J; Tamburino C; Wood DA; Jilaihawi H; Blanke P; Makkar RR; Latib A; Colombo A; Tarantini G; Raju R; Binder RK; Nguyen G; Freeman M; Ribeiro HB; Kapadia S; Min J; Feuchtner G; Gurtvich R; Alqoofi F; Pelletier M; Ussia GP; Napodano M; de Brito FS; Kodali S; Norgaard BL; Hansson NC; Pache G; Canovas SJ; Zhang H; Leon MB; Webb JG; Leipsic J
    Circulation; 2013 Jul; 128(3):244-53. PubMed ID: 23748467
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Annular size and interaction with trans-catheter aortic valves for treatment of severe bicuspid aortic valve stenosis: Insights from the BEAT registry.
    Moscarella E; Mangieri A; Giannini F; Tchetchè D; Kim WK; Sinning JM; Landes U; Kornowski R; De Backer O; Nickenig G; De Biase C; Søndergaard L; De Marco F; Bedogni F; Ancona M; Montorfano M; Regazzoli D; Stefanini G; Toggweiler S; Tamburino C; Immè S; Tarantini G; Sievert H; Schäfer U; Kempfert J; Wöehrle J; Latib A; Calabrò P; Medda M; Tespili M; Colombo A; Ielasi A
    Int J Cardiol; 2022 Feb; 349():31-38. PubMed ID: 34843819
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantitative Prediction of Paravalvular Leak in Transcatheter Aortic Valve Replacement Based on Tissue-Mimicking 3D Printing.
    Qian Z; Wang K; Liu S; Zhou X; Rajagopal V; Meduri C; Kauten JR; Chang YH; Wu C; Zhang C; Wang B; Vannan MA
    JACC Cardiovasc Imaging; 2017 Jul; 10(7):719-731. PubMed ID: 28683947
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of Transcatheter Aortic Valve Replacement between Self-Expanding versus Balloon-Expandable Valves in Patients with Small Aortic Annulus.
    Lee YJ; Lee SJ; Hong SJ; Shim CY; Ahn CM; Kim JS; Kim BK; Hong GR; Ko YG; Choi D; Jang Y; Hong MK
    Korean Circ J; 2021 Mar; 51(3):222-231. PubMed ID: 33655721
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Common Calcified Femoral Artery Rupture After Intravascular Lithotripsy for TAVR Implantation.
    Spaccarotella C; Mongiardo A; Sorrentino S; Polimeni A; Petullà M; De Rosa S; Indolfi C
    JACC Case Rep; 2020 Jun; 2(6):882-885. PubMed ID: 34317373
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of Left Ventricular Outflow Tract Calcification on Procedural Outcomes After Transcatheter Aortic Valve Replacement.
    Okuno T; Asami M; Heg D; Lanz J; Praz F; Hagemeyer D; Brugger N; Gräni C; Huber A; Spirito A; Räber L; Stortecky S; Windecker S; Pilgrim T
    JACC Cardiovasc Interv; 2020 Aug; 13(15):1789-1799. PubMed ID: 32763071
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Anatomical risk models for paravalvular leak and landing zone complications for balloon-expandable transcatheter aortic valve replacement.
    Condado JF; Corrigan FE; Lerakis S; Parastatidis I; Stillman AE; Binongo JN; Stewart J; Mavromatis K; Devireddy C; Leshnower B; Guyton R; Forcillo J; Patel A; Thourani VH; Block PC; Babaliaros V
    Catheter Cardiovasc Interv; 2017 Oct; 90(4):690-700. PubMed ID: 28471092
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Impact of Left Ventricular Outflow Tract Calcification on Outcomes Following Transcatheter Aortic Valve Replacement.
    Musallam A; Buchanan KD; Yerasi C; Dheendsa A; Zhang C; Shea C; Case BC; Forrestal BJ; Satler LF; Ben-Dor I; Torguson R; Rogers T; Waksman R
    Cardiovasc Revasc Med; 2022 Feb; 35():1-7. PubMed ID: 34598904
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Infective Endocarditis Following Transcatheter Aortic Valve Replacement: Comparison of Balloon- Versus Self-Expandable Valves.
    Regueiro A; Linke A; Latib A; Ihlemann N; Urena M; Walther T; Husser O; Herrmann C; Nombela-Franco L; Cheema A; Le Breton H; Stortecky S; Kapadia S; Bartorelli L; Sinning JM; Amat-Santos I; Munoz-Garcia J; Lerakis S; Gutíerrez-Ibanes E; Abdel-Wahab M; Tchetche D; Testa L; Eltchaninoff H; Livi U; Castillo JC; Jilaihawi H; Webb G; Barbanti M; Kodali S; de Brito Jr S; Ribeiro B; Miceli A; Fiorina C; Actis Dato GM; Rosato F; Serra V; Masson JB; Wijeysundera C; Mangione A; Ferreira MC; Lima C; Carvalho A; Abizaid A; Marino A; Esteves V; Andrea C.M.; Messika-Zeitoun D; Himbert D; Kim WK; Pellegrini C; Auffret V; Nietlispach F; Pilgrim T; Durand E; Lisko J; Makkar R; Lemos P; Leon B; Puri R; San Roman A; Vahanian A; Søndergaard L; Mangner N; Rodés-Cabau J
    Circ Cardiovasc Interv; 2019 Nov; 12(11):e007938. PubMed ID: 31694412
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantity and location of aortic valve calcification predicts paravalvular leakage after transcatheter aortic valve replacement: a systematic review and meta-analysis.
    Shi J; Li W; Zhang T; Han C; Wang Z; Pei X; Li X; Zhao Z; Wang P; Han J; Chen S
    Front Cardiovasc Med; 2023; 10():1170979. PubMed ID: 37293280
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Differences in blood flow dynamics between balloon- and self-expandable valves in patients with aortic stenosis undergoing transcatheter aortic valve replacement.
    Takahashi Y; Kamiya K; Nagai T; Tsuneta S; Oyama-Manabe N; Hamaya T; Kazui S; Yasui Y; Saiin K; Naito S; Mizuguchi Y; Takenaka S; Tada A; Ishizaka S; Kobayashi Y; Omote K; Sato T; Shingu Y; Kudo K; Wakasa S; Anzai T
    J Cardiovasc Magn Reson; 2023 Oct; 25(1):60. PubMed ID: 37880721
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impact of Aortic Root Anatomy and Geometry on Paravalvular Leak in Transcatheter Aortic Valve Replacement With Extremely Large Annuli Using the Edwards SAPIEN 3 Valve.
    Tang GHL; Zaid S; George I; Khalique OK; Abramowitz Y; Maeno Y; Makkar RR; Jilaihawi H; Kamioka N; Thourani VH; Babaliaros V; Webb JG; Htun NM; Attinger-Toller A; Ahmad H; Kaple R; Sharma K; Kozina JA; Kaneko T; Shah P; Hirji SA; Desai ND; Anwaruddin S; Jagasia D; Herrmann HC; Basra SS; Szerlip MA; Mack MJ; Mathur M; Tan CW; Don CW; Sharma R; Gafoor S; Zhang M; Kapadia SR; Mick SL; Krishnaswamy A; Amoroso N; Salemi A; Wong SC; Kini AS; Rodés-Cabau J; Leon MB; Kodali SK
    JACC Cardiovasc Interv; 2018 Jul; 11(14):1377-1387. PubMed ID: 29960755
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Undersizing but overfilling eliminates the gray zones of sizing for transcatheter aortic valve replacement with the balloon-expandable bioprosthesis.
    Patsalis PC; Kloppe A; Plicht B; Schöne D; Schiedat F; Aweimer A; Kara K; Haldenwang PL; Strauch JT; Buck T; Mügge A
    Int J Cardiol Heart Vasc; 2020 Oct; 30():100593. PubMed ID: 32775601
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transcatheter Aortic Valve Implantation for Severe Bicuspid Aortic Stenosis - 2 Years Follow up Experience From India.
    Kumar V; Sengottuvelu G; Singh VP; Rastogi V; Seth A
    Front Cardiovasc Med; 2022; 9():817705. PubMed ID: 35966565
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.