These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 39133989)

  • 1. PCD-CT enables contrast media reduction in abdominal imaging compared to an individualized kV-adapted contrast media injection protocol on EID-CT.
    Hoeijmakers EJI; Stammen L; Wildberger JE; Eijsvoogel NG; Hersbach JM; Pernot JCJG; Flohr TG; Martens B; Jeukens CRLPN
    Eur J Radiol; 2024 Oct; 179():111680. PubMed ID: 39133989
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reduced versus standard dose contrast volume for contrast-enhanced abdominal CT in overweight and obese patients using photon counting detector technology vs. second-generation dual-source energy integrating detector CT.
    Hagen F; Estler A; Hofmann J; Walder L; Faby S; Almarie B; Nikolaou K; Wrazidlo R; Horger M
    Eur J Radiol; 2023 Dec; 169():111153. PubMed ID: 38250749
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta: Intraindividual Comparison to Energy-Integrating Detector Computed Tomography at Equal Radiation Dose.
    Euler A; Higashigaito K; Mergen V; Sartoretti T; Zanini B; Schmidt B; Flohr TG; Ulzheimer S; Eberhard M; Alkadhi H
    Invest Radiol; 2022 Feb; 57(2):115-121. PubMed ID: 34352805
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Contrast-Enhanced Abdominal CT with Clinical Photon-Counting Detector CT: Assessment of Image Quality and Comparison with Energy-Integrating Detector CT.
    Higashigaito K; Euler A; Eberhard M; Flohr TG; Schmidt B; Alkadhi H
    Acad Radiol; 2022 May; 29(5):689-697. PubMed ID: 34389259
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Image quality of abdominal photon-counting CT with reduced contrast media dose: Evaluation of reduced contrast media protocols during the COVID19 pandemic supply shortage.
    Layer YC; Isaak A; Mesropyan N; Kupczyk PA; Luetkens JA; Dell T; Attenberger UI; Kuetting D
    Heliyon; 2024 Mar; 10(6):e28142. PubMed ID: 38533048
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reduced Intravenous Contrast Dose Portal Venous Phase Photon-Counting Computed Tomography Compared With Conventional Energy-Integrating Detector Portal Venous Phase Computed Tomography.
    Dane B; Mabud T; Melamud K; Ginocchio L; Smereka P; Okyere M; O'Donnell T; Megibow A
    J Comput Assist Tomogr; 2024 Sep-Oct 01; 48(5):675-682. PubMed ID: 38595174
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter.
    Rajendran K; Voss BA; Zhou W; Tao S; DeLone DR; Lane JI; Weaver JM; Carlson ML; Fletcher JG; McCollough CH; Leng S
    Invest Radiol; 2020 Feb; 55(2):91-100. PubMed ID: 31770297
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of run-off computed tomography angiography on a first-generation photon-counting detector CT scanner - Comparison with low-kVp energy-integrating CT.
    Rippel K; Decker JA; Wudy R; Trzaska T; Haerting M; Kroencke TJ; Schwarz F; Scheurig-Muenkler C
    Eur J Radiol; 2023 Jan; 158():110645. PubMed ID: 36525704
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies.
    Gutjahr R; Halaweish AF; Yu Z; Leng S; Yu L; Li Z; Jorgensen SM; Ritman EL; Kappler S; McCollough CH
    Invest Radiol; 2016 Jul; 51(7):421-9. PubMed ID: 26818529
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Image Quality and Radiation Dose of CTPA With Iodine Maps: A Prospective Randomized Study of High-Pitch Mode Photon-Counting Detector CT Versus Energy-Integrating Detector CT.
    Pannenbecker P; Heidenreich JF; Grunz JP; Huflage H; Gruschwitz P; Patzer TS; Feldle P; Bley TA; Petritsch B
    AJR Am J Roentgenol; 2024 Feb; 222(2):e2330154. PubMed ID: 37966036
    [No Abstract]   [Full Text] [Related]  

  • 11. Visualization of bone details in a novel photon-counting dual-source CT scanner-comparison with energy-integrating CT.
    Bette SJ; Braun FM; Haerting M; Decker JA; Luitjens JH; Scheurig-Muenkler C; Kroencke TJ; Schwarz F
    Eur Radiol; 2022 May; 32(5):2930-2936. PubMed ID: 34936011
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Individually Body Weight-Adapted Contrast Media Application in Computed Tomography Imaging of the Liver at 90 kVp.
    Martens B; Hendriks BMF; Eijsvoogel NG; Wildberger JE; Mihl C
    Invest Radiol; 2019 Mar; 54(3):177-182. PubMed ID: 30721159
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Individualized Scan Protocols in Abdominal Computed Tomography: Radiation Versus Contrast Media Dose Optimization.
    Martens B; Jost G; Mihl C; Nijssen EC; Wildberger JE; Schmidt B; Flohr T; Pietsch H
    Invest Radiol; 2022 Jun; 57(6):353-358. PubMed ID: 34935651
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Submillisievert Abdominal Photon-Counting CT versus Energy-integrating Detector CT for Urinary Calculi Detection: Impact on Diagnostic Confidence.
    Huflage H; Kunz AS; Patzer TS; Pichlmeier S; Westhofen T; Gruschwitz P; Heidenreich JF; Lennartz S; Bley TA; Grunz JP
    Radiology; 2024 Jul; 312(1):e232453. PubMed ID: 39078296
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Task-based automatic keV selection: leveraging routine virtual monoenergetic imaging for dose reduction on clinical photon-counting detector CT
    Rajendran K; Bruesewitz M; Swicklik J; Ferrero A; Thorne J; Yu L; McCollough C; Leng S
    Phys Med Biol; 2024 May; 69(11):. PubMed ID: 38648795
    [No Abstract]   [Full Text] [Related]  

  • 16. Saving Contrast Media in Coronary CT Angiography with Photon-Counting Detector CT.
    Cundari G; Deilmann P; Mergen V; Ciric K; Eberhard M; Jungblut L; Alkadhi H; Higashigaito K
    Acad Radiol; 2024 Jan; 31(1):212-220. PubMed ID: 37532596
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultra-high-resolution photon-counting detector computed tomography of the lungs: Phantom and clinical assessment of radiation dose and image quality.
    Chamberlin JH; Smith CD; Maisuria D; Parrish J; van Swol E; Mah E; Emrich T; Schoepf UJ; Varga-Szemes A; O'Doherty J; Munden RF; Tipnis SV; Baruah D; Kabakus IM
    Clin Imaging; 2023 Dec; 104():110008. PubMed ID: 37862910
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results.
    Symons R; Reich DS; Bagheri M; Cork TE; Krauss B; Ulzheimer S; Kappler S; Bluemke DA; Pourmorteza A
    Invest Radiol; 2018 Mar; 53(3):135-142. PubMed ID: 28926370
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Photon-Counting Versus Energy-Integrating Detector CT Angiography of the Lower Extremity in a Human Cadaveric Model With Continuous Extracorporeal Perfusion.
    Gruschwitz P; Hartung V; Kleefeldt F; Ergün S; Huflage H; Peter D; Hendel R; Patzer TS; Pannenbecker P; Kuhl PJ; Bley TA; Petritsch B; Grunz JP
    Invest Radiol; 2023 Oct; 58(10):740-745. PubMed ID: 37185253
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT.
    Decker JA; Bette S; Lubina N; Rippel K; Braun F; Risch F; Woźnicki P; Wollny C; Scheurig-Muenkler C; Kroencke TJ; Schwarz F
    Eur J Radiol; 2022 Mar; 148():110181. PubMed ID: 35121331
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.