These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
113 related articles for article (PubMed ID: 39137606)
1. Does the proximal screw type affect stress and strain in pastern arthrodesis with locking plate in horses? de Souza AF; Pereira CAM; Fürst A; Kümmerle JM; De Zoppa ALDV Res Vet Sci; 2024 Oct; 178():105378. PubMed ID: 39137606 [TBL] [Abstract][Full Text] [Related]
2. A mechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial locking compression plate and two abaxial transarticular cortical screws versus an axial dynamic compression plate and two abaxial transarticular cortical screws. Sod GA; Riggs LM; Mitchell CF; Martin GS Vet Surg; 2011 Jul; 40(5):571-8. PubMed ID: 21521241 [TBL] [Abstract][Full Text] [Related]
3. Comparison of a 3-hole 4.5-mm Dynamic Compression Plate and a 7-hole 5.5-mm Y Locking Compression Plate for Arthrodesis of the Proximal Interphalangeal Joint in Horses-an Ex Vivo Biomechanical Study. Latorre CAS; de Souza AF; Ramos PAR; Nóbrega FS; van de Graaf GMM; Pereira CAM; Ferrigno CRA; Hendrickson DA; De Zoppa ALDV J Equine Vet Sci; 2020 Nov; 94():103252. PubMed ID: 33077103 [TBL] [Abstract][Full Text] [Related]
4. In vitro biomechanical comparison of a 4.5 mm narrow locking compression plate construct versus a 4.5 mm limited contact dynamic compression plate construct for arthrodesis of the equine proximal interphalangeal joint. Ahern BJ; Showalter BL; Elliott DM; Richardson DW; Getman LM Vet Surg; 2013 Apr; 42(3):335-9. PubMed ID: 23445267 [TBL] [Abstract][Full Text] [Related]
5. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of 2 different LCP systems. Vidović A; Jansen D; Schwan S; Goldstein A; Ludtka C; Brehm W Tierarztl Prax Ausg G Grosstiere Nutztiere; 2020 Feb; 48(1):25-34. PubMed ID: 32059234 [TBL] [Abstract][Full Text] [Related]
6. Mechanical Properties and Failure Mode of Proximal Screw Fixation Technique Using Locking Compression Plate for Proximal Interphalangeal Arthrodesis in Horses: An Ex Vivo Study. de Souza AF; Pereira CAM; Costa C; Fürst A; Kümmerle JM; De Zoppa ALV Vet Comp Orthop Traumatol; 2024 Nov; 37(6):263-272. PubMed ID: 38834168 [TBL] [Abstract][Full Text] [Related]
7. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of 3-hole 4.5 mm locking compression plate and 3-hole 4.5 mm narrow dynamic compression plate, with two transarticular 5.5 mm cortex screws. Zoppa AL; Santoni B; Puttlitz CM; Cochran K; Hendrickson DA Vet Surg; 2011 Feb; 40(2):253-9. PubMed ID: 21244444 [TBL] [Abstract][Full Text] [Related]
8. Proximal interphalangeal joint arthrodesis using a combination plate-screw technique in 53 horses (1994-2003). Knox PM; Watkins JP Equine Vet J; 2006 Nov; 38(6):538-42. PubMed ID: 17124844 [TBL] [Abstract][Full Text] [Related]
9. In vitro biomechanical comparison of a 5-hole 4.5 mm locking compression plate and 5-hole 4.5 mm dynamic compression plate for equine proximal interphalangeal joint arthrodesis. Seo JP; Yamaga T; Tsuzuki N; Yamada K; Haneda S; Furuoka H; Sasaki N Vet Surg; 2014 Jul; 43(5):606-11. PubMed ID: 24512440 [TBL] [Abstract][Full Text] [Related]
10. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of two 7-hole 3.5-mm broad and two 5-hole 4.5-mm narrow dynamic compression plates. Watt BC; Edwards RB; Markel MD; McCabe R; Wilson DG Vet Surg; 2002; 31(1):85-93. PubMed ID: 11778172 [TBL] [Abstract][Full Text] [Related]
11. In vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: prototype equine spoon plate versus axially positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion. Sod GA; Mitchell CF; Hubert JD; Martin GS; Gill MS Vet Surg; 2007 Dec; 36(8):792-9. PubMed ID: 18067621 [TBL] [Abstract][Full Text] [Related]
12. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular cortical screws inserted in lag fashion. Sod GA; Riggs LM; Mitchell CF; Hubert JD; Martin GS Vet Surg; 2010 Jan; 39(1):83-90. PubMed ID: 20210950 [TBL] [Abstract][Full Text] [Related]
13. Proximal interphalangeal arthrodesis in 22 horses. Schaer TP; Bramlage LR; Embertson RM; Hance S Equine Vet J; 2001 Jul; 33(4):360-5. PubMed ID: 11469768 [TBL] [Abstract][Full Text] [Related]
14. Comparison of limited-contact dynamic compression plate and locking compression plate constructs for proximal interphalangeal joint arthrodesis in the horse. Rocconi RA; Carmalt JL; Sampson SN; Elder SH; Gilbert EE Can Vet J; 2015 Jun; 56(6):615-9. PubMed ID: 26028685 [TBL] [Abstract][Full Text] [Related]
15. Minimally invasive proximal interphalangeal joint arthrodesis using a locking compression plate and tissue engineering in horses: a pilot study. Seo JP; Yamaga T; Tsuzuki N; Yamada K; Haneda S; Furuoka H; Tabata Y; Sasaki N Can Vet J; 2014 Nov; 55(11):1050-6. PubMed ID: 25392547 [TBL] [Abstract][Full Text] [Related]
16. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of three 4.5-mm and two 5.5-mm cortical screws. Watt BC; Edwards RB; Markel MD; McCabe R; Wilson DG Vet Surg; 2001; 30(3):287-94. PubMed ID: 11340561 [TBL] [Abstract][Full Text] [Related]
17. Biomechanical Comparison of Bicortical, Unicortical, and Unicortical Far-Cortex-Abutting Screw Fixations in Plated Comminuted Midshaft Clavicle Fractures. Croley JS; Morris RP; Amin A; Lindsey RW; Gugala Z J Hand Surg Am; 2016 Jun; 41(6):703-11. PubMed ID: 27113909 [TBL] [Abstract][Full Text] [Related]
18. Proximal interphalangeal locking compression plate for pastern arthrodesis in horses. Hicks RB; Glass KG; Watkins JP Equine Vet J; 2021 Jun; ():. PubMed ID: 34060117 [TBL] [Abstract][Full Text] [Related]
19. Retrospective analysis of factors associated with outcome of proximal interphalangeal joint arthrodesis in 82 horses including Warmblood and Thoroughbred sport horses and Quarter Horses (1992-2014). Herthel TD; Rick MC; Judy CE; Cohen ND; Herthel DJ Equine Vet J; 2016 Sep; 48(5):557-64. PubMed ID: 26289294 [TBL] [Abstract][Full Text] [Related]
20. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: two parallel transarticular headless tapered variable pitch screws versus two parallel transarticular AO cortical bone screws inserted in lag fashion. Gudehus T; Sod GA; Riggs LM; Mitchell CF; Martin GS Vet Surg; 2011 Apr; 40(3):261-5. PubMed ID: 21361995 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]