These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
223 related articles for article (PubMed ID: 39158988)
1. Nocturnal Hypoglycemia in the Era of Continuous Glucose Monitoring. Kulzer B; Freckmann G; Ziegler R; Schnell O; Glatzer T; Heinemann L J Diabetes Sci Technol; 2024 Sep; 18(5):1052-1060. PubMed ID: 39158988 [TBL] [Abstract][Full Text] [Related]
2. Prolonged nocturnal hypoglycemia is common during 12 months of continuous glucose monitoring in children and adults with type 1 diabetes. Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group Diabetes Care; 2010 May; 33(5):1004-8. PubMed ID: 20200306 [TBL] [Abstract][Full Text] [Related]
3. Numerical and clinical precision of continuous glucose monitoring in Colombian patients treated with insulin infusion pump with automated suspension in hypoglycemia. Gómez AM; Marín Sánchez A; Muñoz OM; Colón Peña CA Endocrinol Nutr; 2015 Dec; 62(10):485-92. PubMed ID: 26531841 [TBL] [Abstract][Full Text] [Related]
4. Effect of Insulin Analogs on Frequency of Non-Severe Hypoglycemia in Patients with Type 1 Diabetes Prone to Severe Hypoglycemia: Much Higher Rates Detected by Continuous Glucose Monitoring than by Self-Monitoring of Blood Glucose-The HypoAna Trial. Agesen RM; Kristensen PL; Beck-Nielsen H; Nørgaard K; Perrild H; Jensen T; Parving HH; Thorsteinsson B; Tarnow L; Pedersen-Bjergaard U Diabetes Technol Ther; 2018 Mar; 20(3):247-256. PubMed ID: 29565719 [TBL] [Abstract][Full Text] [Related]
5. Prevention of nocturnal hypoglycemia using predictive alarm algorithms and insulin pump suspension. Buckingham B; Chase HP; Dassau E; Cobry E; Clinton P; Gage V; Caswell K; Wilkinson J; Cameron F; Lee H; Bequette BW; Doyle FJ Diabetes Care; 2010 May; 33(5):1013-7. PubMed ID: 20200307 [TBL] [Abstract][Full Text] [Related]
6. Nighttime hypoglycemia in Japanese children with type 1 diabetes mellitus treated with multiple daily injection insulin therapy. Abe Y; Urakami T; Suzuki J; Morita S; Araki M; Mizota M; Sasaki G; Mori J; Tatematsu T; Mine Y; Yoshida K; Kikuchi T Endocr J; 2023 Jul; 70(7):677-685. PubMed ID: 37019657 [TBL] [Abstract][Full Text] [Related]
7. Factors associated with nocturnal hypoglycemia in at-risk adolescents and young adults with type 1 diabetes. Wilson DM; Calhoun PM; Maahs DM; Chase HP; Messer L; Buckingham BA; Aye T; Clinton PK; Hramiak I; Kollman C; Beck RW; Diabetes Technol Ther; 2015 Jun; 17(6):385-91. PubMed ID: 25761202 [TBL] [Abstract][Full Text] [Related]
8. Preventing hypoglycemia using predictive alarm algorithms and insulin pump suspension. Buckingham B; Cobry E; Clinton P; Gage V; Caswell K; Kunselman E; Cameron F; Chase HP Diabetes Technol Ther; 2009 Feb; 11(2):93-7. PubMed ID: 19848575 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of a Predictive Low-Glucose Management System In-Clinic. Buckingham BA; Bailey TS; Christiansen M; Garg S; Weinzimer S; Bode B; Anderson SM; Brazg R; Ly TT; Kaufman FR Diabetes Technol Ther; 2017 May; 19(5):288-292. PubMed ID: 28221823 [TBL] [Abstract][Full Text] [Related]
10. Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities. Rodbard D Diabetes Technol Ther; 2016 Feb; 18 Suppl 2(Suppl 2):S3-S13. PubMed ID: 26784127 [TBL] [Abstract][Full Text] [Related]
12. "Let the Algorithm Do the Work": Reduction of Hypoglycemia Using Sensor-Augmented Pump Therapy with Predictive Insulin Suspension (SmartGuard) in Pediatric Type 1 Diabetes Patients. Biester T; Kordonouri O; Holder M; Remus K; Kieninger-Baum D; Wadien T; Danne T Diabetes Technol Ther; 2017 Mar; 19(3):173-182. PubMed ID: 28099035 [TBL] [Abstract][Full Text] [Related]
13. A Randomized Clinical Trial of the Effect of Continuous Glucose Monitoring on Nocturnal Hypoglycemia, Daytime Hypoglycemia, Glycemic Variability, and Hypoglycemia Confidence in Persons with Type 1 Diabetes Treated with Multiple Daily Insulin Injections (GOLD-3). Ólafsdóttir AF; Polonsky W; Bolinder J; Hirsch IB; Dahlqvist S; Wedel H; Nyström T; Wijkman M; Schwarcz E; Hellman J; Heise T; Lind M Diabetes Technol Ther; 2018 Apr; 20(4):274-284. PubMed ID: 29608107 [TBL] [Abstract][Full Text] [Related]
14. Assessing sensor accuracy for non-adjunct use of continuous glucose monitoring. Kovatchev BP; Patek SD; Ortiz EA; Breton MD Diabetes Technol Ther; 2015 Mar; 17(3):177-86. PubMed ID: 25436913 [TBL] [Abstract][Full Text] [Related]
15. Prediction of lowest nocturnal blood glucose level based on self-monitoring of blood glucose in Japanese patients with type 2 diabetes. Sakurai K; Kawai Y; Yamazaki M; Komatsu M J Diabetes Complications; 2018 Dec; 32(12):1118-1123. PubMed ID: 30293932 [TBL] [Abstract][Full Text] [Related]
16. A randomized trial of a home system to reduce nocturnal hypoglycemia in type 1 diabetes. Maahs DM; Calhoun P; Buckingham BA; Chase HP; Hramiak I; Lum J; Cameron F; Bequette BW; Aye T; Paul T; Slover R; Wadwa RP; Wilson DM; Kollman C; Beck RW; Diabetes Care; 2014 Jul; 37(7):1885-91. PubMed ID: 24804697 [TBL] [Abstract][Full Text] [Related]
17. Optimising use of rate-of-change trend arrows for insulin dosing decisions using the FreeStyle Libre flash glucose monitoring system. Ajjan RA; Cummings MH; Jennings P; Leelarathna L; Rayman G; Wilmot EG Diab Vasc Dis Res; 2019 Jan; 16(1):3-12. PubMed ID: 30175925 [TBL] [Abstract][Full Text] [Related]
19. Predicting Nocturnal Hypoglycemia with Measures of Physical Activity Intensity in Adolescent Athletes with Type 1 Diabetes. Jaggers JR; King KM; Watson SE; Wintergerst KA Diabetes Technol Ther; 2019 Jul; 21(7):406-408. PubMed ID: 31265348 [TBL] [Abstract][Full Text] [Related]
20. Prediction of Nocturnal Hypoglycemia From Continuous Glucose Monitoring Data in People With Type 1 Diabetes: A Proof-of-Concept Study. Jensen MH; Dethlefsen C; Vestergaard P; Hejlesen O J Diabetes Sci Technol; 2020 Mar; 14(2):250-256. PubMed ID: 31390891 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]