These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 3917235)

  • 1. Magnetic resonance imaging at high-strength magnetic fields.
    Herfkens RJ; Johnson GA
    Magn Reson Annu; 1985; ():197-215. PubMed ID: 3917235
    [No Abstract]   [Full Text] [Related]  

  • 2. Magnetic resonance imaging at very high fields: current status.
    Kramer DM; Kormos DW; Yeung HN
    Magn Reson Annu; 1987; ():287-327. PubMed ID: 3079342
    [No Abstract]   [Full Text] [Related]  

  • 3. Cardiac magnetic resonance imaging at 3.0 T.
    Fenchel M; Kramer U; Nael K; Miller S
    Top Magn Reson Imaging; 2007 Apr; 18(2):95-104. PubMed ID: 17621223
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [3 Tesla magnetic resonance imaging of the brain. Better morphological and functional images with higher magnetic field strength].
    Larsson EM; Ståhlberg F
    Lakartidningen; 2005 Feb 14-20; 102(7):460-3. PubMed ID: 15768694
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cardiac magnetic resonance spectroscopy: a window for studying physiology.
    Horn M
    Methods Mol Med; 2006; 124():225-48. PubMed ID: 16506424
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-field-strength magnetic resonance: potential and limits.
    Ladd ME
    Top Magn Reson Imaging; 2007 Apr; 18(2):139-52. PubMed ID: 17621228
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Computation of transmitted and received B1 fields in magnetic resonance imaging.
    Milles J; Zhu YM; Chen NK; Panych LP; Gimenez G; Guttmann CR
    IEEE Trans Biomed Eng; 2006 May; 53(5):885-95. PubMed ID: 16686411
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Safety aspects of magnetic resonance imaging and magnetic resonance spectroscopy applications in medicine and biology: I. Biomagnetic effects.
    Mathur-De Vré R
    Arch Belg; 1987; 45(9-10):394-424. PubMed ID: 3331256
    [No Abstract]   [Full Text] [Related]  

  • 9. [Pulse triggering in magnetic resonance tomography in high-field strength].
    Langkowski JH; Heller M; Maas R; Kooijman H; Grabbe E; Bücheler E
    Rofo; 1987 Sep; 147(3):333-6. PubMed ID: 2823342
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multi-dimensional magnetic resonance imaging in a stray magnetic field.
    Baltisberger JH; Hediger S; Emsley L
    J Magn Reson; 2005 Jan; 172(1):79-84. PubMed ID: 15589410
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An inverted-microstrip resonator for human head proton MR imaging at 7 tesla.
    Zhang X; Ugurbil K; Sainati R; Chen W
    IEEE Trans Biomed Eng; 2005 Mar; 52(3):495-504. PubMed ID: 15759580
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 3.0 Tesla Magnetic Resonance. Part 2: morphological and functional brain imaging.
    Scarabino T; Giannatempo GM; Nemore F; Di Salle F; Esposito F; Elefante R; Salvolini U; Di Costanzo A; Tedeschi G; Blasi G; Bertolini A
    Radiol Med; 2003 Mar; 105(3):150-61. PubMed ID: 12835638
    [No Abstract]   [Full Text] [Related]  

  • 13. [The development of an active shimming system for 0.2T open-style permanent magnet MRI].
    Chen L; Peng C; Zhu X
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2004 Apr; 21(2):288-91. PubMed ID: 15143561
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Technologic advances in magnetic resonance imaging and spectroscopy for cardiovascular applications.
    Henkelman RM
    Curr Opin Radiol; 1990 Aug; 2(4):542-6. PubMed ID: 2204391
    [No Abstract]   [Full Text] [Related]  

  • 15. Microimaging at 14 tesla using GESEPI for removal of magnetic susceptibility artifacts in T(2)(*)-weighted image contrast.
    Yang QX; Smith MB; Briggs RW; Rycyna RE
    J Magn Reson; 1999 Nov; 141(1):1-6. PubMed ID: 10527737
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Distinguishability for magnetic resonance-electrical impedance tomography (MR-EIT).
    Altunel H; Eyüboğlu BM; Köksal A
    Phys Med Biol; 2007 Jan; 52(2):375-87. PubMed ID: 17202621
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Effect of high frequency spin resonance on image production in nuclear magnetic resonance tomography].
    Wach P; Stollberger R
    Biomed Tech (Berl); 1990; 35 Suppl 2():110-1. PubMed ID: 2223948
    [No Abstract]   [Full Text] [Related]  

  • 18. Active shielding of cylindrical saddle-shaped coils: application to wire-wound RF coils for very low field NMR and MRI.
    Bidinosti CP; Kravchuk IS; Hayden ME
    J Magn Reson; 2005 Nov; 177(1):31-43. PubMed ID: 16099186
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Physiological monitoring of small animals during magnetic resonance imaging.
    Mirsattari SM; Bihari F; Leung LS; Menon RS; Wang Z; Ives JR; Bartha R
    J Neurosci Methods; 2005 Jun; 144(2):207-13. PubMed ID: 15910980
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Canada's largest magnet finds home in new MRI program in London.
    OReilly M
    CMAJ; 1997 Jan; 156(1):69-70. PubMed ID: 9006571
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.