These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 3917384)

  • 1. Indican interference with six commercial procedures for measuring total bilirubin.
    Poon R; Hinberg IH
    Clin Chem; 1985 Jan; 31(1):92-4. PubMed ID: 3917384
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A 2,4-dichlorophenyl diazonium-based method for total bilirubin without interference from indican in uremic sera.
    McPhaul L; Kershaw M; Tilque D; Eckfeldt JH
    Clin Chem; 1985 Jul; 31(7):1229-31. PubMed ID: 3924443
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Indican interference in bilirubin assays: a classical solution still applies.
    Henrich LM; Bruns DE; Haverstick DM; Reynolds VG; Boyd JC
    Clin Chem; 2007 Feb; 53(2):359-61. PubMed ID: 17259249
    [No Abstract]   [Full Text] [Related]  

  • 4. Diazo-based assay for total bilirubin in a coated thin film evaluated.
    Weiss JS; Sundberg MW; Dappen GM; Spayd RW; Wu TW; Jatlow P; Seligson D
    Clin Chem; 1984 Aug; 30(8):1310-3. PubMed ID: 6744577
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Automated Jendrassik-Grof method for measurement of bilirubin in serum with the Greiner Selective Analyzer (GSA II D), and comparison with the method involving diazotized 2,4-dichloroaniline.
    Cherian AG; Soldin SJ; Hill JG
    Clin Chem; 1981 May; 27(5):748-52. PubMed ID: 7226499
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A modified Malloy-Evelyn procedure for total bilirubin in microsamples.
    Shihabi ZK; Scaro J
    Am J Med Technol; 1977 Oct; 43(10):1004-7. PubMed ID: 920747
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Inaccurate values for direct bilirubin with some commonly used direct bilirubin procedures.
    Chan KM; Scott MG; Wu TW; Clouse RE; Calvin DR; Koenig J; Lichti DA; Ladenson JH
    Clin Chem; 1985 Sep; 31(9):1560-3. PubMed ID: 4028405
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Naproxen metabolites interfere with certain bilirubin assays: elimination of interference by using a Roche bilirubin assay on the Hitachi 917 analyzer.
    Dasgupta A; Langman LJ; Johnson M; Chow L
    Am J Clin Pathol; 2010 Jun; 133(6):878-83. PubMed ID: 20472845
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A modification of the acid diazo coupling method (Malloy-Evelyn) for the determination of serum total bilirubin.
    Parviainen MT
    Scand J Clin Lab Invest; 1997 May; 57(3):275-9. PubMed ID: 9238764
    [TBL] [Abstract][Full Text] [Related]  

  • 10. One-step protocol for assays of total and direct bilirubin with stable combined reagents.
    Fossati P; Ponti M; Prencipe L; Tarenghi G
    Clin Chem; 1989 Jan; 35(1):173-6. PubMed ID: 2910561
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Single-reagent method for rapid determination of total bilirubin with the "CentrifiChem" Analyzer.
    Ertingshausen G; Fabiny Byrd DL; Tiffany TO; Casey SJ
    Clin Chem; 1973 Dec; 19(12):1366-9. PubMed ID: 4757365
    [No Abstract]   [Full Text] [Related]  

  • 12. Centrifugal analyzer method for total bilirubin in serum by use of diazotized 2-chloroaniline-5-sulfonic acid.
    Brody JP; Valdes R; Savory J
    Clin Chem; 1979 Feb; 25(2):205-8. PubMed ID: 759015
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Modified Jendrassik--Grof method for bilirubins adapted to the Abbott Bichromatic Analyzer.
    Mori L
    Clin Chem; 1978 Oct; 24(10):1841-5. PubMed ID: 699298
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Jendrassik--Grof analysis for total and direct bilirubin in serum with a centrifugal analyzer.
    Garber CC
    Clin Chem; 1981 Aug; 27(8):1410-6. PubMed ID: 7273400
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improved stable diazonium salt procedure for determination of total serum bilirubin.
    Morin LG
    Clin Chim Acta; 1973 Aug; 47(1):111-2. PubMed ID: 4747798
    [No Abstract]   [Full Text] [Related]  

  • 16. Studies on the interference by haemoglobin in the determination of bilirubin.
    van der Woerd-de Lange JA; Guder WG; Schleicher E; Paetzke I; Schleithoff M; Wieland OH
    J Clin Chem Clin Biochem; 1983 Jul; 21(7):437-43. PubMed ID: 6619741
    [TBL] [Abstract][Full Text] [Related]  

  • 17. New kinetic procedure for the measurement of conjugated bilirubin with a centrifugal analyzer.
    Valdes R; Brody JP; Savory J
    Ann Clin Lab Sci; 1979; 9(3):251-7. PubMed ID: 464545
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A single nonaqueous diazo reagent for the rapid determination of bilirubin in serum without lipemic interference.
    Morin LG
    Clin Chim Acta; 1976 Aug; 71(1):9-14. PubMed ID: 971528
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of the ABA-100 procedure for total and direct bilirubin in serum or plasma.
    Jaberg C; McConnell K; Potter JL; Platt MS
    Clin Chem; 1975 Sep; 21(10):1511-2. PubMed ID: 1157323
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Three direct spectrophotometric methods for determination of total bilirubin in neonatal and adult serum, adapted to the Technicon RA-1000 analyzer.
    Harrison SP; Barlow IM
    Clin Chem; 1989 Sep; 35(9):1980-6. PubMed ID: 2776331
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.