These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Injuries to the bronchi and lungs caused by laser-ignited endotracheal tube fires. Duncavage JA; Ossoff RH; Rouman WC; Toohill RJ; Almagro UA; Carl GA; Aronson S Otolaryngol Head Neck Surg; 1984 Dec; 92(6):639-43. PubMed ID: 6440081 [TBL] [Abstract][Full Text] [Related]
6. Incidence of malposition of polyvinylchloride and red rubber left-sided double-lumen tubes and clinical sequelae. Cohen E; Neustein SM; Goldofsky S; Camunas JL J Cardiothorac Vasc Anesth; 1995 Apr; 9(2):122-7. PubMed ID: 7780066 [TBL] [Abstract][Full Text] [Related]
7. Is flexible bronchoscopy necessary to confirm the position of double-lumen tubes before thoracic surgery? de Bellis M; Accardo R; Di Maio M; La Manna C; Rossi GB; Pace MC; Romano V; Rocco G Eur J Cardiothorac Surg; 2011 Oct; 40(4):912-6. PubMed ID: 21802958 [TBL] [Abstract][Full Text] [Related]
8. Advantages of a new polyvinyl chloride double-lumen tube in thoracic surgery. Burton NA; Watson DC; Brodsky JB; Mark JB Ann Thorac Surg; 1983 Jul; 36(1):78-84. PubMed ID: 6860029 [TBL] [Abstract][Full Text] [Related]
10. A cost analysis of reusable and disposable flexible optical scopes for intubation. Tvede MF; Kristensen MS; Nyhus-Andreasen M Acta Anaesthesiol Scand; 2012 May; 56(5):577-84. PubMed ID: 22338623 [TBL] [Abstract][Full Text] [Related]
11. [A cost comparison of Pall filters versus chemical or thermal disinfection of ventilator tubes]. Scherrer M; Salrein G; Mattowitz R; Daschner F Anaesthesist; 1990 Sep; 39(9):445-9. PubMed ID: 2240566 [TBL] [Abstract][Full Text] [Related]
12. Flow resistances of disposable double-lumen, single-lumen, and Univent tubes. Slinger PD; Lesiuk L J Cardiothorac Vasc Anesth; 1998 Apr; 12(2):142-4. PubMed ID: 9583542 [TBL] [Abstract][Full Text] [Related]
13. [Classification of disposable medical plastics and search for alternatives without polyvinyl chloride in the Hospital Virgen de las Nieves (Granada, Spain)]. Sañudo Hacar P; Blanco MG; Martínez E; Duarte JA; González A; Hernández M; Martínez M; Cueto E; Navajas JA; Navarrete MJ Rev Calid Asist; 2012; 27(6):341-4. PubMed ID: 22537777 [TBL] [Abstract][Full Text] [Related]
14. Educating surgeons on intraoperative disposable supply costs during laparoscopic cholecystectomy: a regional health system's experience. Gitelis M; Vigneswaran Y; Ujiki MB; Denham W; Talamonti M; Muldoon JP; Linn JG Am J Surg; 2015 Mar; 209(3):488-92. PubMed ID: 25586597 [TBL] [Abstract][Full Text] [Related]
15. Comparison of the resistances of double-lumen endobronchial tubes. Hammond JE; Wright DJ Br J Anaesth; 1984 Mar; 56(3):299-302. PubMed ID: 6231044 [TBL] [Abstract][Full Text] [Related]
16. Cost-minimization analysis of jumbo reusable forceps versus disposable forceps in a high-volume ambulatory endoscopy center. Hogan RB; Santa-Cruz R; Weeks ES; Alexander L; Hogan RB Gastrointest Endosc; 2009 Feb; 69(2):284-8. PubMed ID: 18725156 [TBL] [Abstract][Full Text] [Related]
17. The urinary catheter as a bronchial blocker. Conacher ID Anaesthesia; 1983 May; 38(5):475-7. PubMed ID: 6859477 [TBL] [Abstract][Full Text] [Related]