21. Multicenter assessment of a hemoglobin A1c point-of-care device for diagnosis of diabetes mellitus. Sobolesky PM; Smith BE; Saenger AK; Schulz K; Apple FS; Scott MG; Wu AHB; Little RR; Fitzgerald RL Clin Biochem; 2018 Nov; 61():18-22. PubMed ID: 30236830 [TBL] [Abstract][Full Text] [Related]
22. Analytical performance evaluation of hemoglobin A1c on an ARKRAY HA-8160 analyzer with newly-developed mobile phase buffer. Yu Y; Zhang X; Lin K Pract Lab Med; 2024 May; 40():e00414. PubMed ID: 38939102 [TBL] [Abstract][Full Text] [Related]
23. Accuracy of a Point-of-Care Hemoglobin A1c Assay. Nathan DM; Griffin A; Perez FM; Basque E; Do L; Steiner B J Diabetes Sci Technol; 2019 Nov; 13(6):1149-1153. PubMed ID: 30943787 [TBL] [Abstract][Full Text] [Related]
24. A Hemoglobinopathy That Produces an Array of Different Hemoglobin A1c Values. Marin MJ; Osa-Andrews B; Maher PA; Wasserfall C; Winter WE; Muzwagi AB; Harris NS J Hematol; 2024 Jun; 13(3):99-103. PubMed ID: 38993739 [TBL] [Abstract][Full Text] [Related]
25. [Analytical problems in determination of hemoglobin A1c and the different ways of its interpretation]. Góth L Orv Hetil; 2009 Apr; 150(16):747-51. PubMed ID: 19362928 [TBL] [Abstract][Full Text] [Related]
26. Comparison of Hb A1c Quantification in the Presence of Hemoglobin Variants of an HPLC Assay with an Enzymatic Assay. Nichols JH; Berman M; Carrillo A; Manning S J Appl Lab Med; 2023 Nov; 8(6):1127-1132. PubMed ID: 37610380 [TBL] [Abstract][Full Text] [Related]
27. Analytical performance evaluation of the Mindray enzymatic assay for hemoglobin A Li M; Wu X; Xie W; Zeng Y; Wang H; Chen H; Xu A; Liu H; Ji L Sci Rep; 2024 May; 14(1):12289. PubMed ID: 38811684 [TBL] [Abstract][Full Text] [Related]
28. Three of 7 hemoglobin A1c point-of-care instruments do not meet generally accepted analytical performance criteria. Lenters-Westra E; Slingerland RJ Clin Chem; 2014 Aug; 60(8):1062-72. PubMed ID: 24865164 [TBL] [Abstract][Full Text] [Related]
29. Analytical performances of the D-100TM hemoglobin testing system (Bio-Rad) for HbA1c assay. Jaisson S; Leroy N; Guillard E; Desmons A; Gillery P Clin Chem Lab Med; 2015 Aug; 53(9):1473-9. PubMed ID: 26011926 [TBL] [Abstract][Full Text] [Related]
30. Analytical evaluation of the ADAMS Urrechaga E J Clin Lab Anal; 2018 Jan; 32(1):. PubMed ID: 28236327 [TBL] [Abstract][Full Text] [Related]
31. Comparability of hemoglobin A1c level measured in capillary versus venous blood sample applying two point-of-care instruments. Keramati T; Razi F; Tootee A; Larijani B J Diabetes Metab Disord; 2014; 13(1):94. PubMed ID: 25408924 [TBL] [Abstract][Full Text] [Related]
32. A comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA Wu X; Chao Y; Wan Z; Wang Y; Ma Y; Ke P; Wu X; Xu J; Zhuang J; Huang X Biochem Med (Zagreb); 2016 Oct; 26(3):353-364. PubMed ID: 27812304 [TBL] [Abstract][Full Text] [Related]
33. A1c Gear: Laboratory quality HbA1c measurement at the point of care. Ejilemele A; Unabia J; Ju H; Petersen JR Clin Chim Acta; 2015 May; 445():139-42. PubMed ID: 25801216 [TBL] [Abstract][Full Text] [Related]
34. [Comparison of HbA1c analyzers: D-10, Variant II Turbo, Cobas Integra 800, and Afinion AS100]. Lee JY; Hong KS; Cho SE Korean J Lab Med; 2010 Aug; 30(4):345-50. PubMed ID: 20805705 [TBL] [Abstract][Full Text] [Related]
35. Evaluation of haemoglobin A1c measurement by an enzymatic method using an automated analyser that has an on-board haemolysis system. Matsumoto H; Uchino M; Kato M Ann Clin Biochem; 2013 Sep; 50(Pt 5):443-9. PubMed ID: 23897101 [TBL] [Abstract][Full Text] [Related]
36. Performance evaluation of the glycated hemoglobin A1c analyzer for point-of-care testing compared with laboratory-based devices: a multicenter validation study. Zhou Y; Yang F; Zhou M; Pan B; Wang B; Guo W; Shao W; Zhu J Scand J Clin Lab Invest; 2024 Sep; 84(5):356-361. PubMed ID: 39217618 [TBL] [Abstract][Full Text] [Related]
37. Haemoglobin A1c: evaluation of a new HbA1c point-of-care analyser Bio-Rad in2it in comparison with the DCA 2000 and central laboratory analysers. Yeo CP; Tan CH; Jacob E Ann Clin Biochem; 2009 Sep; 46(Pt 5):373-6. PubMed ID: 19487414 [TBL] [Abstract][Full Text] [Related]
38. Can the Afinion HbA1c Point-of-Care instrument be an alternative method for the Tosoh G8 in the case of Hb-Tacoma? Lenters-Westra E; Strunk A; Campbell P; Slingerland RJ Scand J Clin Lab Invest; 2017 Feb; 77(1):2-7. PubMed ID: 27191339 [TBL] [Abstract][Full Text] [Related]
39. Improvement in the Quality of HbA1c Determination by Using Commutable Specimens With IFCC-Assigned Values. Zhou R; Gao ZQ; Tong Q; Zuo C; Song ZX; Wang W; Wang QT Lab Med; 2017 May; 48(2):148-153. PubMed ID: 28371852 [TBL] [Abstract][Full Text] [Related]
40. Point-of-Care Hemoglobin A1c Testing: An Evidence-Based Analysis. Health Quality Ontario Ont Health Technol Assess Ser; 2014; 14(8):1-30. PubMed ID: 26316922 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]