These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 39196699)

  • 21. Multicenter assessment of a hemoglobin A1c point-of-care device for diagnosis of diabetes mellitus.
    Sobolesky PM; Smith BE; Saenger AK; Schulz K; Apple FS; Scott MG; Wu AHB; Little RR; Fitzgerald RL
    Clin Biochem; 2018 Nov; 61():18-22. PubMed ID: 30236830
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Analytical performance evaluation of hemoglobin A1c on an ARKRAY HA-8160 analyzer with newly-developed mobile phase buffer.
    Yu Y; Zhang X; Lin K
    Pract Lab Med; 2024 May; 40():e00414. PubMed ID: 38939102
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Accuracy of a Point-of-Care Hemoglobin A1c Assay.
    Nathan DM; Griffin A; Perez FM; Basque E; Do L; Steiner B
    J Diabetes Sci Technol; 2019 Nov; 13(6):1149-1153. PubMed ID: 30943787
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A Hemoglobinopathy That Produces an Array of Different Hemoglobin A1c Values.
    Marin MJ; Osa-Andrews B; Maher PA; Wasserfall C; Winter WE; Muzwagi AB; Harris NS
    J Hematol; 2024 Jun; 13(3):99-103. PubMed ID: 38993739
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Analytical problems in determination of hemoglobin A1c and the different ways of its interpretation].
    Góth L
    Orv Hetil; 2009 Apr; 150(16):747-51. PubMed ID: 19362928
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of Hb A1c Quantification in the Presence of Hemoglobin Variants of an HPLC Assay with an Enzymatic Assay.
    Nichols JH; Berman M; Carrillo A; Manning S
    J Appl Lab Med; 2023 Nov; 8(6):1127-1132. PubMed ID: 37610380
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Analytical performance evaluation of the Mindray enzymatic assay for hemoglobin A
    Li M; Wu X; Xie W; Zeng Y; Wang H; Chen H; Xu A; Liu H; Ji L
    Sci Rep; 2024 May; 14(1):12289. PubMed ID: 38811684
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Three of 7 hemoglobin A1c point-of-care instruments do not meet generally accepted analytical performance criteria.
    Lenters-Westra E; Slingerland RJ
    Clin Chem; 2014 Aug; 60(8):1062-72. PubMed ID: 24865164
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Analytical performances of the D-100TM hemoglobin testing system (Bio-Rad) for HbA1c assay.
    Jaisson S; Leroy N; Guillard E; Desmons A; Gillery P
    Clin Chem Lab Med; 2015 Aug; 53(9):1473-9. PubMed ID: 26011926
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Analytical evaluation of the ADAMS
    Urrechaga E
    J Clin Lab Anal; 2018 Jan; 32(1):. PubMed ID: 28236327
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparability of hemoglobin A1c level measured in capillary versus venous blood sample applying two point-of-care instruments.
    Keramati T; Razi F; Tootee A; Larijani B
    J Diabetes Metab Disord; 2014; 13(1):94. PubMed ID: 25408924
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA
    Wu X; Chao Y; Wan Z; Wang Y; Ma Y; Ke P; Wu X; Xu J; Zhuang J; Huang X
    Biochem Med (Zagreb); 2016 Oct; 26(3):353-364. PubMed ID: 27812304
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A1c Gear: Laboratory quality HbA1c measurement at the point of care.
    Ejilemele A; Unabia J; Ju H; Petersen JR
    Clin Chim Acta; 2015 May; 445():139-42. PubMed ID: 25801216
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Comparison of HbA1c analyzers: D-10, Variant II Turbo, Cobas Integra 800, and Afinion AS100].
    Lee JY; Hong KS; Cho SE
    Korean J Lab Med; 2010 Aug; 30(4):345-50. PubMed ID: 20805705
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of haemoglobin A1c measurement by an enzymatic method using an automated analyser that has an on-board haemolysis system.
    Matsumoto H; Uchino M; Kato M
    Ann Clin Biochem; 2013 Sep; 50(Pt 5):443-9. PubMed ID: 23897101
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Performance evaluation of the glycated hemoglobin A1c analyzer for point-of-care testing compared with laboratory-based devices: a multicenter validation study.
    Zhou Y; Yang F; Zhou M; Pan B; Wang B; Guo W; Shao W; Zhu J
    Scand J Clin Lab Invest; 2024 Sep; 84(5):356-361. PubMed ID: 39217618
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Haemoglobin A1c: evaluation of a new HbA1c point-of-care analyser Bio-Rad in2it in comparison with the DCA 2000 and central laboratory analysers.
    Yeo CP; Tan CH; Jacob E
    Ann Clin Biochem; 2009 Sep; 46(Pt 5):373-6. PubMed ID: 19487414
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Can the Afinion HbA1c Point-of-Care instrument be an alternative method for the Tosoh G8 in the case of Hb-Tacoma?
    Lenters-Westra E; Strunk A; Campbell P; Slingerland RJ
    Scand J Clin Lab Invest; 2017 Feb; 77(1):2-7. PubMed ID: 27191339
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Improvement in the Quality of HbA1c Determination by Using Commutable Specimens With IFCC-Assigned Values.
    Zhou R; Gao ZQ; Tong Q; Zuo C; Song ZX; Wang W; Wang QT
    Lab Med; 2017 May; 48(2):148-153. PubMed ID: 28371852
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Point-of-Care Hemoglobin A1c Testing: An Evidence-Based Analysis.
    Health Quality Ontario
    Ont Health Technol Assess Ser; 2014; 14(8):1-30. PubMed ID: 26316922
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.